US$599.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30555-2014: Rules for screw expander (unit) thermal acceptance test Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30555-2014 | English | 599 |
Add to Cart
|
5 days [Need to translate]
|
Rules for screw expander (unit) thermal acceptance test
| Valid |
GB/T 30555-2014
|
PDF similar to GB/T 30555-2014
Basic data | Standard ID | GB/T 30555-2014 (GB/T30555-2014) | | Description (Translated English) | Rules for screw expander (unit) thermal acceptance test | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K59 | | Classification of International Standard | 27.040 | | Word Count Estimation | 26,243 | | Date of Issue | 5/6/2014 | | Date of Implementation | 10/28/2014 | | Quoted Standard | GB/T 2624.1; GB/T 2624.2; GB/T 2624.3; GB/T 2624.4; GB 3102.3; GB/T 8117.1-2008; GB/T 30554-2014 | | Regulation (derived from) | National Standards Bulletin No. 9 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the test methods and computer program for low temperature waste heat to generate electricity or drive back pressure and condensing steam screw expander (Group) Thermal Performance. This Standard specifies test preparation, uniform |
GB/T 30555-2014: Rules for screw expander (unit) thermal acceptance test---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rules for screw expander (unit) thermal acceptance test
ICS 27.040
K59
National Standards of People's Republic of China
Screw expander (group) performance acceptance testing procedures
Issued on. 2014-05-06
2014-10-28 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms, definitions and symbols 1
3.1 Terms and definitions
3.2 Symbols and Definitions 2
3.3 ensure that the definition of values \u200b\u200b3
4 Guideline 4
Preplanning 4.1 Test 4
4.2 Test preparation phase of the agreement and arrangement 4
Measuring 4.3 test boundaries and needed 4
4.4 Test Program 6
7 4.5 Test preparation
4.6 Test tuning 7
4.7 Acceptance Test 8
Repeat 9 4.8 Acceptance Test
4.9 Test Uncertainty 9
5 measurement technology and instrumentation 9
5.1 Overview 9
12 5.2 Power Measurement
5.3 Flow Measurement 13
5.4 pressure measurement 15
5.5 Condensing screw expander exhaust pressure measurement 16
5.6 Temperature measurement 16
5.7 steam quality measurement 18
6 The results of calculation 18
6.1 Calculation ready before 18
6.2 Calculation of results 18
Comparative test results and amendment 7 with the guaranteed value of 20
7.1 guaranteed and guaranteed working conditions 20
7.2 steam consumption rate and output power of 20 amendments
Generating capacity of 7.3 units of thermal fluid amendment 20
7.4 Correction 21
7.5 Fixed variables considered in 21
7.6 Comparison with the guaranteed value of 21
References 22
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Electrical Equipment Industrial Association.
The standard screw expander by the National Standardization Technical Committee (SAC/TC512) centralized.
This standard drafting of the main unit. Jiangxi Huadian Power limited liability company.
Participated in the drafting of this standard. Xi'an Thermal Power Research Institute Co., Ltd., Shanghai Power Equipment Research Institute, Shenzhen Energy Set
Mission Moon Bay Gas Turbine Power Plant.
The main drafters of this standard. Shi Yanzhou, Huda, Wang Xingping, Yu Yuefeng, Su Jian.
Screw expander (group) performance acceptance testing procedures
1 Scope
This standard specifies the test methods for low temperature waste heat power generation or driving (group) and thermal performance with a back-pressure condensing steam screw expander and
Calculation program. This standard specifies the test preparation, uniform rules implementation and evaluation, also contains details of the test conditions.
This standard applies to two-phase working fluid as soda, saturated steam or superheated steam screw expander unit, and a non-water as the working fluid (such as a low boiling point
Working fluid) twin screw expander cycle unit.
If you have any complex or special cases, the manufacturer and the purchaser not covered by this standard should reach an appropriate agreement before signing the contract.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2624 (all parts) with a differential pressure measuring device mounted to round pipe full pipe fluid flow (ISO 5167 (all
Part).2003)
GB 3102.3 Quantities and units of mechanics
GB/T 8117.1-2008 steam turbine thermal acceptance tests - Part 1. Method A --- Large Condensing Steam Turbine
High accuracy test (IEC 60953-1.1990)
GB/T 30554-2014 screw expander term
3 Terms, definitions and symbols
3.1 Terms and Definitions
GB/T 30554-2014 define the following terms and definitions apply to this document.
3.1.1
Rated condition ratedcondition
Under the provisions of (contract) conditions, screw expander at rated inlet and outlet parameters and speed operating conditions.
3.1.2
Rated power ratedpoweroutput
Screw expander running at rated conditions, regulating valve fully open when power issued screw expansion function. This power is also called the nameplate power.
3.1.3
Gross output power grosspoweroutput
Generator terminal screw expansion unit measured output power.
3.1.4
Auxiliary power consumption auxiliarypower
Screw expansion unit for all electrical equipment electric power consumed.
3.1.5
The net power output netpoweroutput
By the end of the generator output power measured gross deducted auxiliary power consumption, to obtain the net power output of the unit.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30555-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30555-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30555-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30555-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|