Path: Home > GB/T > Page552 > GB/T 30515-2014 Home > Standard_List > GB/T > Page552 > GB/T 30515-2014
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30515-2014 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Petroleum products -- Transparent and opaque liquids -- Determination of kinematic viscosity and calculation of dynamic viscosity
| Valid |
GB/T 30515-2014
|
PDF similar to GB/T 30515-2014
Basic data | Standard ID | GB/T 30515-2014 (GB/T30515-2014) | | Description (Translated English) | Petroleum products -- Transparent and opaque liquids -- Determination of kinematic viscosity and calculation of dynamic viscosity | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | E30 | | Classification of International Standard | 75.080 | | Word Count Estimation | 17,166 | | Date of Issue | 2/19/2014 | | Date of Implementation | 6/1/2014 | | Quoted Standard | GB/T 5144-2005; GB/T 1884; GB/T 1885; GB/T 6682; GB/T 30514-2014; JJG 155; SH/T 0173-1992; SH/T 0526; SH/T 0604 | | Adopted Standard | ISO 3104-1994, MOD | | Regulation (derived from) | 2014 National Standards Bulletin No. 2 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the method using a glass capillary viscometer movement kinematic viscosity of liquid petroleum products, and its calculation of dynamic viscosity. This Standard applies to transparent and opaque liquid petroleum products. |
GB/T 30515-2014: Petroleum products -- Transparent and opaque liquids -- Determination of kinematic viscosity and calculation of dynamic viscosity ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Petroleum products. Transparent and opaque liquids. Determination of kinematic viscosity and calculation of dynamic viscosity
ICS 75.080
E30
National Standards of People's Republic of China
Transparent and opaque liquid petroleum products Kinematic viscosity
Determination of dynamic viscosity and calculation
(ISO 3104.1994, MOD)
Issued on. 2014-02-19
2014-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted law revision using ISO 3104.1994 "Transparent and opaque liquid petroleum products - Determination of kinematic viscosity and
Dynamic viscosity calculation. "
This standard and ISO 3104.1994 and the technical differences for the following reasons.
--- In Chapter 2, "Normative references", increasing the GB/T 514-2005, GB/T 1885, SH/T 0173-1992,
Reference SH/T 0526, SH/T 0604 and JJG155 standards and procedures;
--- In Chapter 6, "instrument", the capillary viscometer type increased in line with SH/T 0173-1992 requirements viscometer;
--- Increased by JJG155 for viscometer calibration and verification of the content in 6.1;
--- In Chapter 9, "transparent liquid viscosity measurement" in order to make the standard more workable, increased if the sample contains
Water, dewatering filter content filter paper, if necessary;
--- 9.3 and 10.5, supplementary transparent and opaque liquid sample density measuring step, to improve methods;
--- Cancel the ISO 3104.1994 Annex C, the contents of which increased in 6.5.2, and delete the original Appendix C Notes.
This standard by the National Standardization Technical Committee on products and lubricant oil (SAC/TC280) proposed.
This standard by the National Petroleum Products and Lubricants Standardization Technical Committee of petroleum fuels and lubricants Technical Committee
(SAC/TC280/SC1) centralized.
This standard is drafted by. China Petroleum & Chemical Corporation Shanghai Gaoqiao, China Petroleum & Chemical Corporation stone
Oil Chemical Research Institute, Chinese Academy of Inspection and Quarantine, the Chemical Institute of Standardization.
Participated in the drafting of this Standard. China Petroleum & Chemical Corporation lubricants R & D (Shanghai) Center, China National Petroleum shares have
Limited oil company EAST lubricants plant.
The main drafters of this standard. Daijian Fang, YANG Ting-ting, Chen Jie, Lu following the full country Yu.
Introduction
The normal operation of many petroleum products and some non-petroleum-based material is used as a lubricant equipment, instruments and equipment typically depends on having
A liquid lubricant suitable viscosity. In addition, many of the kinematic viscosity fuel oil for determining the optimum fuel storage, handling and operating conditions
is very important. Thus, for many products, the precise determination of its kinematic viscosity is very necessary.
Transparent and opaque liquid petroleum products Kinematic viscosity
Determination of dynamic viscosity and calculation
Warning. The application of this standard may involve some hazardous materials, operations and equipment, but not all security related thereto ask
Questions are recommendations. Users Before using this standard has the responsibility to develop appropriate security and protection measures, and determine the relevant regulatory restrictions applicable
Versatility.
1 Scope
The method of using a glass capillary viscometer movement kinematic viscosity of liquid petroleum products specified in this standard, and its dynamic viscosity meter
Calculation method.
This standard applies to transparent and opaque liquid petroleum products.
Note. The intrinsic viscosity of this sample results obtained in standard assay related mainly applied to shear stress and shear rate is proportional to the liquid (ie, Newtonian fluid
body). However, if the viscosity of the liquid by the effect of shear rate is very significant, capillary viscometer results obtained with different diameters may be different.
This standard also includes under certain conditions exhibit non-Newtonian fluid properties of the fuel oil viscosity measurement test procedures and accuracy requirements.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 514-2005 petroleum products Glass liquid thermometer technical conditions
GB/T 1884 crude oil and liquid petroleum products - Laboratory determination of density (density meter method) (GB/T 1884-2000,
eqv ISO 3675.1998)
GB/T 1885 Petroleum Measurement Tables
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)
GB/T 30514-2014 motion glass capillary viscometer operating instructions and specifications (ISO 3105.1994, MOD)
JJG155 Working capillary viscometer test procedures
SH/T 0173-1992 glass capillary viscometer technical conditions
SH/T 0526 Standard Oil Viscosity
SH/T 0604 crude oil and petroleum products densitometry (U-shaped vibrating tube method) (SH/T 0604-2000, eqv ISO 12185.1996)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Kinematic viscosity kinematicviscosity
Resistance suffered a liquid flow under gravity.
Price & DeliveryUS$399.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30515-2014: Petroleum products -- Transparent and opaque liquids -- Determination of kinematic viscosity and calculation of dynamic viscosity Status: Valid
|