US$949.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27664.2-2011: Non-destructive testing -- Characterization and verification of ultrasonic test equipment -- Part 2: Probes Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 27664.2-2011 | English | 949 |
Add to Cart
|
7 days [Need to translate]
|
Non-destructive testing -- Characterization and verification of ultrasonic test equipment -- Part 2: Probes
| Valid |
GB/T 27664.2-2011
|
PDF similar to GB/T 27664.2-2011
Basic data | Standard ID | GB/T 27664.2-2011 (GB/T27664.2-2011) | | Description (Translated English) | Non-destructive testing -- Characterization and verification of ultrasonic test equipment -- Part 2: Probes | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N77 | | Classification of International Standard | 19.100 | | Word Count Estimation | 43,425 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-05-01 | | Quoted Standard | GB/T 12604.1; GB/T 19001; GB/T 19799.2; GB/T 27664.1; GB/T 27664.3; EN 1330-4; EN 12223 | | Adopted Standard | EN 12668-2-2001, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 22 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the following two categories of focus or focus ultrasonic nondestructive testing probe and test methods: a) generating transverse or longitudinal wave transducers single or dual transducer contact probe, b) immersion probe. Provisions of this section relating ultrasound with material values ??, is based on the ultrasonic velocity of longitudinal waves (5920 �� 50) m/s and shear ultrasonic velocity of (3255 �� 30) m/s in steel. This section does not provide for periodic inspection by the probe method. This section applies to the center frequency at 0. 5MHz ~ 15MHz focus or focus within the probe. |
GB/T 27664.2-2011: Non-destructive testing -- Characterization and verification of ultrasonic test equipment -- Part 2: Probes ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Non-destructive testing Characterization and verification of ultrasonic test equipment Part 2. Probes
ICS 19.100
N77
National Standards of People's Republic of China
Non-destructive testing - Ultrasonic testing and performance testing equipment
Part 2. Probe
ultrasonictestequipment-Part 2. Probes
Issued on. 2011-12-30
2012-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions, symbols and abbreviations 1
4 General requirements 4
5 probe technology provided by the manufacturer index 5
6 testing apparatus 6
6.1 Electronic Instrument 6
6.2 test blocks and other appliances 7
7 probe performance requirements 10
10 7.1 Appearance
7.2 RF pulse waveform 11
7.3 pulse spectrum and bandwidth 12
7.4 Relative pulse-echo sensitivity 12
7.5 distance amplitude curve 13
7.6 electrical impedance or capacitance 15
7.7 beam parameters immersion probe 15
7.8 contact probe, direct probes and single transducer probe beam parameters 23
7.9 contact shear wave transducers single oblique probe beam parameters 26
7.10 double-contact transducer to direct the probe beam parameters 30
7.11 beam parameters contactless shear wave transducers double oblique probe 32
Calculation Appendix A (normative) unfocused probe near-field length of 34
Calibration block Annex B (informative) dipped by 36 probe
Foreword
GB/T 27664 "non-destructive testing and performance testing ultrasonic testing equipment" is divided into three parts.
--- Part 1. Apparatus;
--- Part 2. Probes;
--- Part 3. Combined equipment.
This section GB/T 27664 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses redrafted law revision adopts the European standard EN12668-2.2001 "NDT ultrasonic testing equipment and performance
Test - Part 2. Probe "(in English), including its No. 1 amendments EN12668-2.2001/Amel.2004.
Text structure and technical content of this section with EN12668-2.2001 agreement.
This portion of EN12668-2.2001 and the difference between the following reasons.
--- Remove the EN foreword, and re-write the foreword;
--- Use the "section" word instead of the "European standard";
--- Deleted Chapter 1 probe testing requirements;
--- Amend the introductory phrase in Chapter 2, "Normative references" in;
International Standard --- Chapter 2 normative references cited in the country has been transformed into a standard, then this part of the direct references thereto
The latest version of the corresponding standards;
--- Chapter 2 Normative references to international standards documents referenced in ISO 9001.1994 and ISO 9002.1994 have been combined with repair
Set to ISO 9001.2008, it is a direct reference to this part of the ISO 9001.2008 corresponding to the national standard of
GB/T 19001-2008;
--- Chapter 2 normative references added GB/T 12604.1-2005 "Terminology for nondestructive testing Ultrasonic testing";
--- Term 3.1,3.2.1 and 3.2.2 respectively terminology GB/T 12604.1-2005 and as defined in 7.2,6.10 2.19
And its definition;
--- In Chapter 4, "probe to ensure the quality" content added c).
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This part is proposed by China Machinery Industry Federation.
This part of the National Technical Committee of Standardization Testing Machine (SAC/TC122) centralized.
This section is drafted. Shantou Institute of Ultrasonic Instruments Co., Ltd., Changchun Mechanical Engineering Research Institute Limited.
The main drafters of this section. Wangxing Xiong, Liu intelligence, Caiheng Hui.
Non-destructive testing - Ultrasonic testing and performance testing equipment
Part 2. Probe
1 Scope
This section GB/T 27664 specifies the following two types of focus or focus ultrasonic probe for detection and non-destructive testing methods.
a) generating transverse or longitudinal wave transducers single or dual transducer contact probes;
b) immersion probe.
Ultrasound and materials related to the value specified in this section is based on longitudinal wave acoustic velocity of (5920 ± 50) m/s and transverse ultrasonic sound
Speed \u200b\u200bof (3255 ± 30) m/s steel.
This part of the cycle test method does not provide for the probe.
This section applies to a center frequency at 0.5MHz ~ 15MHz range focus or focus probe.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 12604.1 Terminology for nondestructive testing Ultrasonic testing (GB/T 12604.1-2005, ISO 5577.2000, IDT)
GB/T 19001 quality management system requirements (GB/T 19001-2008, ISO 9001.2008, IDT)
GB/T 19799.2 NDT ultrasonic testing calibration block No. 2 (GB/T 19799.2-2005, ISO 7963. 1985, IDT)
GB/T 27664.1 performance and test NDT ultrasonic testing equipment - Part 1. Apparatus
GB/T 27664.3 performance destructive ultrasonic testing and inspection equipment - Part 3. Combined equipment
EN1330-4 Terminology for nondestructive testing - Part 4. Ultrasonic testing - Terminology (Nondestructivetesting-Terminology-
Part 4. Termsusedinultrasonictesting)
EN12223 NDT ultrasonic testing calibration block No. 1 Specification (Non-destructivetesting-Ultrasonicexamina-
tion-SpecificationforcalibrationblockNo.1)
3 Terms and definitions, symbols and abbreviations
GB/T 12604.1 and EN1330-4 defined and the following terms and definitions apply to this document.
3.1
Blind deadzone
Close to a region of the workpiece is detected under the surface in this area meaningful reflectors can not be displayed.
3.2
Focus and near-field length
3.2.1
Focal length focaldistance
Focusing probe distance from the sound source to focus.
|