US$299.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27504-2011: Pressure gauge error table Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 27504-2011 | English | 299 |
Add to Cart
|
3 days [Need to translate]
|
Pressure gauge error table
| Valid |
GB/T 27504-2011
|
PDF similar to GB/T 27504-2011
Basic data | Standard ID | GB/T 27504-2011 (GB/T27504-2011) | | Description (Translated English) | Pressure gauge error table | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N11 | | Classification of International Standard | 17.100 | | Word Count Estimation | 13,187 | | Date of Issue | 2011-10-31 | | Date of Implementation | 2012-01-01 | | Quoted Standard | GB/T 8170 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 15 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the basic error limit gauge and hysteresis, tapping displacement, ambient temperature, etc. indication error allowable value. This standard applies to sensitive components of the elastic element is different accuracy levels, measuring range of pressure gauges (referred to as instrumentation). This standard specifies the instrument working environment when the temperature deviates from reference temperature indication error limits, this standard applies only to the elastic modulus temperature coefficient "K" of 0. 04%/��C of the instrument. |
GB/T 27504-2011: Pressure gauge error table---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Pressure gauge error table
ICS 17.100
N11
National Standards of People's Republic of China
Gauge error table
Issued on. 2011-10-31
2012-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard is drafted by. Xi'an Institute of Industrial Automation Instrumentation.
Participated in the drafting of this standard. West Instrument Group Co., Ltd. instrument factory, Hongqi Instrument Co., Ltd., Ningbo Long Welding Science and Technology
Ltd., Leier Da Instrument Co., Ltd., Beijing Const Instrument Technology Co., Ltd.
The main drafters of this standard. Luo Juan, Li Zhenghua.
Gauge error table
1 Scope
This standard specifies the basic error limit gauges and hysteresis, tapping displacement allowable value, ambient temperature, etc. indication errors.
This standard applies to the elastic element is different sensor accuracy class, measuring range of the gauge (the meter).
This standard specifies the instrument operating ambient temperature deviates from the reference temperature indication of the margin of error, this standard applies only to the elastic modulus of the material
The temperature coefficient "K" of the instrument 0.04%/℃ of.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 8170 numerical rounding rules
3 Technical requirements
3.1 Accuracy class
Meter accuracy level is divided into.
0.1, 0.16, 0.25, 0.4, 1.0, 1.6, 2.5, 4.0.
3.2 units of measurement
The standard unit of measurement used are. Pa, kPa, MPa.
3.3 numerical rounding rules
The value of this standard into homes by rounding rules GB/T 8170 implementation of the provisions.
3.4 Basic error limit
3.4.1 Basic error limits and accuracy of the correspondence between the grades as defined in Table 1.
Table 1 Basic error limit
Accuracy class 0.1 0.16 0.25 0.4 1.0 1.6 2.5 4.0
Basic error limit
(Percentage range) /%
± 0.10 ± 0.16 ± 0.25 ± 0.4 ± 1 ± 1.6 ± 2.5 ± 4
3.4.2 Different accuracy class, measuring range of the instrument, the basic error allowable value specified in Table 2 and Table 3.
3.5 Backlash
Correspondence between the provisions of 3.5.1 hysteresis and accuracy class in Table 4.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 27504-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 27504-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 27504-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27504-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|