   US$489.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25660.1-2010: CNC small size worm milling machines -- Part 1: Testing of the accuracy Status: Valid    
      
    
  
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF | 
		 
			| GB/T 25660.1-2010 | English | 489 | 
   Add to Cart
   | 
                    4 days [Need to translate]
                 | 
                    CNC small size worm milling machines -- Part 1: Testing of the accuracy
                 | Valid | 
                    GB/T 25660.1-2010
                 | 
		 
	 
     
     
  
	 
       PDF similar to GB/T 25660.1-2010 
    
   
    
     
          
  
  
    
  Basic data             |  Standard ID  |          GB/T 25660.1-2010 (GB/T25660.1-2010) |               |  Description (Translated English)  |          CNC small size worm milling machines -- Part 1: Testing of the accuracy |               |  Sector / Industry  |          National Standard (Recommended) |               |  Classification of Chinese Standard  |          J56 |               |  Classification of International Standard  |          25.040.20 |               |  Word Count Estimation  |          21,284 |               |  Date of Issue  |          2010-12-23 |               |  Date of Implementation  |          2011-07-01 |               |  Quoted Standard  |          GB/T 10089-1988; GB/T 17421.1-1988; GB/T 17421.2-2000 |               |  Regulation (derived from)  |          National Standard Approval Announcement 2010 No.10 (Total No.165) |               |  Issuing agency(ies)  |          General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |               |  Summary  |          This standard specifies the geometric precision CNC milling small worm, position accuracy and precision of test requirements and test methods. This section applies to a maximum workpiece diameter to 80mm, maximum modulus to the CNC machining of small worm milling 3. 5mm.  |         
  GB/T 25660.1-2010: CNC small size worm milling machines -- Part 1: Testing of the accuracy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.  
CNC small size worm milling machines Part 1. Testing of the accuracy
ICS 25.040.20
J56
National Standards of People's Republic of China
CNC milling small worm - Part 1. Testing of the accuracy
CNCsmalsizewormmilingmachines-Part 1. Testingoftheaccuracy
Issued on. 2010-12-23
2011-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 General requirements 1
Geometric tests 2 4
5 position accuracy test 12
6 17 accuracy test work
Foreword
GB/T 25660 "Small worm CNC milling machine" is divided into two parts.
--- Part 1. Testing of the accuracy;
--- Part 2. Technical requirements.
This section GB/T Part of 125,660.
This part is proposed by China Machinery Industry Federation.
This part of the National Metal Cutting Machine Standardization Technical Committee (SAC/TC22) centralized.
This section is drafted. Four Chuanpushenning River Machine Co., Ltd., Chengdu Instrument Machine Tool Institute.
The main drafters of this section. Money civilization, Huang Ling, Zhang Qin.
CNC milling small worm - Part 1. Testing of the accuracy
1 Scope
This section GB/T 25660 specifies the geometric precision CNC milling small worm, location accuracy and precision requirements and testing
Testing method.
This section applies to a maximum workpiece diameter 80mm, maximum modulus to 3.5mm CNC machining small worm milling machine (hereinafter referred to as
"machine tool").
2 Normative references
The following documents contain provisions which, through reference GB/T 25660 in this section constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 10089-1988 cylindrical worm and precision
GB/T 17421.1-1998 Test code for machine tools - Part 1. under no-load or finishing conditions Geometric accuracy of machines (eqv
ISO 230-1.1996)
GB/T 17421.2-2000 Test code for machine tools - Part 2. CNC axis positioning accuracy and repeatability of determination
(Eqv ISO 230-2.1997)
3 General requirements
3.1 section all linear dimensions are in millimeters (mm) as the unit; angle deviation is mainly represented by the ratio. In some cases the
Clear, but also with microradians (μrad) or arcsec ( ") as the unit in terms of its relationship formula below.
0.010/1000 = 10 × 10-6 = 10μrad≈2 "
3.2 Use this section shall GB/T 17421.1, especially heating pre-installation testing tools, spindles and other moving parts, testing
Recommended methods and inspection precision tools. Installation of the machine level and ambient temperature should meet the following requirements.
--- According to GB/T 17421.1-1998 3.1 Adjustment of the machine installation level. The level meter on the mounting plate, a level in
Vertical and horizontal readings are not more than 0.04/1000;
--- When test, the ambient temperature should be maintained at 20 ℃ ± 2 ℃. Machine Tool and Gage placed a long enough time in the measurement environment to
Ensure steady state is reached before the test.
3.3 part of the order given in the test project does not represent the actual inspection order. In order to facilitate assembly and disassembly inspection and testing tools, according to any one of
Italian order of inspection.
3.4 inspection tools, according to the structural characteristics of the machine does not have to test all the items in this section. For the purpose of acceptance testing requirements
When, by the user to obtain the manufacturer agreed to choose some interesting test items, but these items should be clearly stated at the time of ordering the machine.
Test tools specified in section 3.5 of example only, you can use the same indicates the amount and precision of other inspection tools. Indicators should have
0.001mm or higher resolution.
3.6 working accuracy test, test specimens shall be carried out after finishing.
3.7 When the software can be used to compensate for some of the test items deviation, the user and the manufacturer's protocol press, can use or not use these compensation
Inspection-related projects under the circumstances. When using a software compensation, should be indicated in the test project.
3.8 When the length of the measured length with the provisions of this section are not at the same time, it should be able to measure the length tolerance GB/T 17421.1-1998 in
Provisions 2.3.1.1 translated. Result of the conversion is less than 0.002, based upon the 0.002 meter.
3.9 axis parallel to the axis of the spindle axis is Z-axis perpendicular to the spindle axis of the X-axis.
   
   
  
  
    
  
    
   
        
       
          
               
 
          |