HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 25228-2010 English PDF

US$519.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 25228-2010: Inspection of grain and oils -- Determination of fumonisins in corn and its products by high liquid chromatography and fluorometer with immunoaffinity column cleanup
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 25228-2010English519 Add to Cart 3 days [Need to translate] Inspection of grain and oils -- Determination of fumonisins in corn and its products by high liquid chromatography and fluorometer with immunoaffinity column cleanup Obsolete GB/T 25228-2010

PDF similar to GB/T 25228-2010


Standard similar to GB/T 25228-2010

GB/T 23779   GB/T 5493   GB/T 5496   GB/T 44336   GB/T 41133   GB/T 25221   

Basic data

Standard ID GB/T 25228-2010 (GB/T25228-2010)
Description (Translated English) Inspection of grain and oils -- Determination of fumonisins in corn and its products by high liquid chromatography and fluorometer with immunoaffinity column cleanup
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard X10
Classification of International Standard 67.040
Word Count Estimation 13,144
Date of Issue 2010-09-26
Date of Implementation 2011-03-01
Quoted Standard GB/T 6682
Adopted Standard AOAC official method 2001.04, MOD
Regulation (derived from) National Standard Approval Announcement 2010 No.6 (Total No.161)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the immunoaffinity column purification by HPLC and immunoaffinity column purification fluorescence spectrometry-Determination Principle of corn and its products fumonisins determination, reagents and materials, instruments and equipment, operating procedures and results. This standard immunoaffinity purification HPLC column applies to corn and corn products and the determination of fumonisins Bl and B2. Immunoaffinity column purification fluorescence spectrometry for the determination of corn and corn products fumonisins total. Immunoaffinity column purification of high mosquito liquid chromatography detection limit of 0. 1mg/kg, immunoaffinity column purification fluorescence spectrometry detection limit of 0. 5mg/kg.

GB/T 25228-2010: Inspection of grain and oils -- Determination of fumonisins in corn and its products by high liquid chromatography and fluorometer with immunoaffinity column cleanup


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inspection of grain and oils.Determination of fumonisins in corn and its products by high liquid chromatography and fluorometer with immunoaffinity column cleanup ICS 67.040 X10 National Standards of People's Republic of China Grain and oil inspection of corn and its products in the fumonotoxin Content determination Immunoaffinity column was highly purified Liquid chromatography and fluorescence spectrophotometry 2010-09-26 release 2011-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released

Foreword

The immunoaffinity column in this standard is purified by high performance liquid chromatography using the International Association of Analytical Chemists. Methodology.2001.04 Determination of fumonisin in maize and maize flakes Immunoaffinity column Purification liquid chromatography "(Officialmethod For ease of use, this standard has the following modifications to AOACofficialmethod2001.04. --- will be applied to the determination of the concentration range is modified to the detection limit, the deletion of the standard laboratory test data table A and Table B, increased Domestic laboratory test data; To modify the requirements for immunoaffinity columns; --- modify the concentration range of the standard curve; --- will be fixed volume from.200μL to 400μL; --- added a blank test; --- simplifies the calculation of the results. Appendix A, Appendix B and Appendix C of this standard are informative. This standard is proposed by the National Grain Bureau. This standard by the National Grain Standardization Technical Committee. This standard is responsible for the drafting unit. State Food Bureau Science Research Institute. This standard participates in the drafting unit. Beijing Zhongwei Weikang Technology Co., Ltd. The main drafters of this standard. Wang Songxue, Wang Xiong, Liu entropy, Zhang Yan, Sun Changpo, Wang Yan. Grain and oil inspection of corn and its products in the fumonotoxin Content determination Immunoaffinity column was highly purified Liquid chromatography and fluorescence spectrophotometry

1 Scope

This standard specifies the use of immunoaffinity column purification of high performance liquid chromatography and immunoaffinity column purification fluorescence spectrophotometric determination of corn and its system The principle, reagents and materials, apparatus and equipment for the determination of fumonisin in products, procedures and results. In this standard, immunoaffinity column purification and high performance liquid chromatography (HPLC) is suitable for the determination of fumonisin B1 and B2 in maize and maize products. The immuno - spectrophotometric method for the determination of the total amount of fumonotoxin in maize and maize products. The detection limit of immunoaffinity column purification and high performance liquid chromatography was 0.1mg/kg. The detection limit of immunoaffinity column was as follows. 0.5 mg/kg.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard. GB/T 6682 Analytical laboratory water specifications and test methods

3 Immunoaffinity Column Chromatography Purification by High Performance Liquid Chromatography

3.1 Principles The samples were purified by immunoaffinity reaction, and the fumarotoxin derived from o-phthalaldehyde was used as fluorescent compound. Reverse phase high performance liquid chromatography The contents of fumonisin B1 and B2 were determined by separation, detection and external standard method. 3.2 Reagents and materials Unless otherwise specified, the reagents used are analytical pure, experimental water should be consistent with GB/T 6682 in the secondary water requirements. 3.2.1 Methanol. Chromatography is pure or comparable in purity. 3.2.2 acetonitrile. pure chromatography, or pure purity. 3.2.3 Sodium dihydrogen phosphate (NaH2PO4 · 2H2O). 3.2.4 Sodium tetraborate (Na2B4O7 · 10H2O). 3.2.5 Sodium chloride. 3.2.6 disodium hydrogen phosphate. 3.2.7 Potassium dihydrogen phosphate. 3.2.8 Potassium chloride. 3.2.9 concentrated hydrochloric acid. 3.2.10 phosphoric acid. 3.2.11 o-phthalaldehyde (OPA). 3.2.12 2-thioethanol (MCE). 3.2.13 0.1mol/L sodium dihydrogen phosphate solution. Weigh 15.6g sodium dihydrogen phosphate (3.2.3), dissolved in water and set the volume of 1L. 3.2.14 0.1mol/L sodium tetraborate solution. Weigh 3.8g sodium tetraborate (3.2.4), dissolved in water and set to 100mL. 3.2.15 2mol/L hydrochloric acid solution. 1 volume of concentrated hydrochloric acid (3.2.9) dissolved in 5 volumes of water.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 25228-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 25228-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 25228-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25228-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.