HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 25084-2010 English PDF

US$629.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 25084-2010: Insulator strings and sets for overhead lines with a nominal voltage greater than 1000 V -- AC power arc tests
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 25084-2010English629 Add to Cart 5 days [Need to translate] Insulator strings and sets for overhead lines with a nominal voltage greater than 1000 V -- AC power arc tests Valid GB/T 25084-2010

PDF similar to GB/T 25084-2010


Standard similar to GB/T 25084-2010

DL/T 1000.1   DB12/ 356   DL/T 1000.3   GB/T 44179   GB/T 24622   GB/T 21421.1   

Basic data

Standard ID GB/T 25084-2010 (GB/T25084-2010)
Description (Translated English) Insulator strings and sets for overhead lines with a nominal voltage greater than 1000 V -- AC power arc tests
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K48
Classification of International Standard 29.080.10
Word Count Estimation 27,227
Date of Issue 2010-09-02
Date of Implementation 2011-02-01
Quoted Standard GB/T 22709-2008; IEC 60862
Adopted Standard IEC 61467-2008, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 4 of 2010 (total 159)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the insulator string group frequency arc test standard test procedures, but also on a short string frequency arc test standard test procedures, This standard applies to a nominal voltage greater than 1000V, frequency 15HZ ~ 100HZ AC overhead lines and traction line with porcelain, glass or composite material consisting of string insulator insulator strings and insulation in the string group, this standard also applies to similar structures substation insulator strings and insulator string group, this standard does not apply to non-metallic pole mounted or tower on the insulator string group, this standard can not be directly used for line post insulators and insulator sets, can not be used bracing type line post insulators, which is described as the standard mounting arrangements can not reproduce their installation conditions, However, the basic principles of this standard can be used to test these insulators in its mounting arrangement, purpose of this standard are: definition of the terms used, the required standard test procedures, evaluation of test results required criteria arc tests not a line insulator specification must-try items specified in this standard standard test procedures and evaluation criteria that are necessary in order to test the elbow arc which provides guidance, not trying to take power arc tests must be done as a common pilot project,

GB/T 25084-2010: Insulator strings and sets for overhead lines with a nominal voltage greater than 1000 V -- AC power arc tests


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Insulator strings and sets for overhead lines with a nominal voltage greater than 1000 V.AC power arc tests ICS 29.080.10 K48 National Standards of People's Republic of China The overhead voltage is higher than 1000V overhead lines Use insulator strings and insulator strings AC frequency arc test (IEC 61467..2008, Insulatorsforoverheadlines- Insulatorstringsandsetslines withanominal voltagegreaterthan1000V-ACpowerarctests, MOD) 2010-09-02 release.2011-02-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 symbols and abbreviations 2 5 test current characteristics 3 6 power supply circuit and return circuit condition 3

7 Insulator string test

7.1 Introduction 5 7.2 Test arrangement 5 7.3 Test current 5 7.4 Power supply circuit and return circuit condition 5 7.5 starting arc 5 7.6 Environmental conditions 7 7.7 Characteristics of test group and power frequency arc 7

8 short string test

8.1 Introduction 7 8.2 Test arrangement 7 8.3 Test current 9 8.4 Power supply circuit and return circuit condition 9 8.5 starting arc 9 8.6 Environmental conditions 9 8.7 Test group and power frequency arc characteristics 9 9 Test Report 9 10 Results 10 10.1 Introduction 10 10.2 Visual inspection 10 10.3 porcelain or glass insulator 10 10.4 composite insulator 10 10.5 Criteria 10 Appendix A (normative appendix) Test arrangement and tower simulation Applicable method example (return circuit) 12 Appendix B (normative appendix) Determination of current square root value 15 B.1 Determination of the square root value of the AC component during the actual duration of the test current B.2 Three peaks method 15 Appendix C (informative) No-load voltage for power frequency power supply 17 Appendix D (informative) Insulated arcs on insulator strings and their true simulation (proper arrangement of fuses) 18 Appendix E (informative) Wind speed in arc test Appendix F (informative) Fault current size and selection of test parameters Appendix G (informative) Technical differences between this standard and IEC 61467..2008 and its causes 22 Reference 23

Foreword

This standard is modified using IEC 61467..2008 "overhead lines with insulators nominal voltage higher than 1000V overhead lines with insulation Sub - string and insulator string AC frequency arc test "(English version). This standard makes some technical changes compared to IEC 61467..2008, with the vertical single line (|) in the chapter And the description of the changes and their reasons in Appendix G. This standard refers to the adoption of international standards of national standards. For ease of use, this standard has been modified as follows. a) Replace the comma as a decimal point with the decimal point "." b) delete the preamble of IEC 61467..2008; c) the word "international standard" is changed to "this standard". Taking into account the applicability of the text, this standard removes Appendix G and Appendix H of IEC 61467..2008. The standard section number of this standard IEC 61467..2008. Appendix A and Appendix B of this standard are normative, Appendix C, Appendix D, Appendix E, Appendix F and Appendix G are informative appendix. This standard is proposed by China Electrical Equipment Industry Association. This standard is nationalized by the National Insulator Standardization Technical Committee (SAC/TC80). The drafting unit of this standard. China Electric Power Research Institute, Xi'an High Voltage Electric Appliance Research Institute Co., Ltd. Xi'an Electric Porcelain Research Institute, State Grid Wuhan High Voltage Research Institute, National Insulator Surge Arrester Quality Supervision and Inspection Center, Dalian Electric Porcelain Co., Ltd., Guangzhou Maike Lin Electric Power Co., Ltd. Division, Xiangfan State Grid Synthetic Insulator Co., Ltd., Dongguan City High Energy Electric Co., Ltd., Xinjiang Xinneng Tianning electrical insulation materials Limited company, Hebei Xinhua High Voltage Electric Co., Ltd., Shandong Thai Light Electric Co., Ltd., Jiangsu Xiangyuan Electric Equipment Co., Ltd. The main drafters of this standard. Wang Lai, Yao Junrui, Wu Guangya, Wei Peng, Fan Jianbin, Zhang Rui, Ren Guixing, Ouyang Xu Dan, Yang Hongjun, Qi Dongbao, and Rong Jun, Teng Guoli, Zhang Hongxiang. The overhead voltage is higher than 1000V overhead lines Use insulator strings and insulator strings AC frequency arc test

1 Scope

This standard specifies the insulator string of the frequency of the arc test standard test procedures, but also proposed a short string of the frequency of arc test standard test program. This standard applies to the nominal voltage higher than 1000V, frequency 15Hz ~ 100Hz AC overhead lines and traction lines with porcelain, glass Or composite insulator string components of the insulator string and insulator string group. This standard also applies to substructural insulator strings and insulator strings of similar structures. This standard does not apply to insulator strings installed on non-metallic poles or towers. This standard can not be directly used for line column insulators and their insulator groups, nor can they be used for pendulum type column insulators, due to The installation arrangement described in this standard does not reproduce its installation. However, the basic principles of this standard can be used for the testing of these insulators and Its installation layout. The purpose of this standard is. Define the terminology used; - standard test procedures; - Criteria for the evaluation of test results. The arc test is not a mandatory item in the line insulator specification. The standard test procedures and evaluation criteria set forth in this standard are for the purpose of being available It is necessary to carry out the arc test to provide guidance, not to arc test as a common test items must be done.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard. GB/T 22709-2008 Porcelain or glass insulator string for overhead lines Insulator mechanical residual strength after damage (IEC 60797. 1984, MOD) Code for design of IEC 60862 overhead transmission lines

3 terms and definitions

The following terms and definitions apply to this standard. Note. Other terms and definitions used in this standard can be found in GB/T 2900.8, GB/T 1001.1-2003 and IEC 60383-2..1993. 3.1 Test test A specified test current is applied to the insulator string or string for a specified duration. 3.2 Test sequence testsequence Three consecutive tests on the same insulator string or string.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 25084-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 25084-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 25084-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25084-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.