US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24985-2010: Test methods for reliability on household and similar room air conditioners Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24985-2010 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Test methods for reliability on household and similar room air conditioners
| Valid |
GB/T 24985-2010
|
PDF similar to GB/T 24985-2010
Basic data | Standard ID | GB/T 24985-2010 (GB/T24985-2010) | | Description (Translated English) | Test methods for reliability on household and similar room air conditioners | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | Y61 | | Classification of International Standard | 97.040.30 | | Word Count Estimation | 15,116 | | Date of Issue | 2010-08-09 | | Date of Implementation | 2010-12-01 | | Quoted Standard | GB/T 2422; GB/T 2900.13; GB/T 5080.1; GB/T 5080.7-1986 | | Regulation (derived from) | National Standard Approval Announcement 2010 No.3 (Total No.158) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the test requirements for household and similar room air conditioner (hereinafter referred to as air conditioners) the reliability of the identification and reliability acceptance testing, trial implementation, determination of test results, , fault analysis and statistical records and test reports test and so on. This standard applies to the use of air-cooled condenser, Hermetic motor-compressor. Household and similar room air conditioner. Reliability Test Methods for other similar products available for implementation. |
GB/T 24985-2010: Test methods for reliability on household and similar room air conditioners---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for reliability on household and similar room air conditioners
ICS 97.040.30
Y61
National Standards of People's Republic of China
Household and similar room air conditioner
Reliability Test Methods
Issued on. 2010-08-09
2010-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms, definitions and symbols 1
General Description 3 4
5 3 Test Requirements
6 Test Example 5
Fault analysis and statistical processing 7 6
Determination of test results 6 8
Test records and test reports 9 7
The formula in Appendix A (normative appendix) MTBF lower confidence limit θL 8
Annex B (informative) Typical trouble and classification 9
Reference 10
Foreword
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee appliances (SAC/TC46) centralized.
This standard is drafted by. Haier Group.
This standard is mainly involved in the drafting unit. China Academy of household appliances, Zhuhai Gree Electric Appliance Co., Ltd., Midea Group Co.,
Guangdong Chigo Air Conditioning Co., Ltd., Jiangsu Chunlan Refrigeration Equipment Co., Ltd., Hisense Kelon Air Conditioner Co., Ltd., Guangzhou CVC certified check
Measured Co., Ningbo Aux Air Conditioning Co., Ltd., Sichuan Changhong Air Conditioner Co., PHAAG, Shenyang Sanyo Air
Tune Ltd., China Saibao Laboratory, Qingdao City Product Quality Supervision and Inspection.
The main drafters. Liwen Dong, Qi Bing, national anti-German, Wang Haijun, Tancheng Bin, Li swift, Luan love East, Feng Lifeng, Zhangqi Bo, Liu Jian,
Bai Wei, Zhong Ming, Wu Xionghua, Pan Yan, Zhang Zhigang, Shang Peng.
This standard is the first release.
Introduction
At present, the reliability of the technology has been widely applied to the automotive, medical, military and aerospace and other fields. Reliability Technology has become a measure of product quality
An important means of volume, long-term practice proves the reliability of technology for improving the quality of products is significant.
China's home appliance industry is a mature industry, China has become the world's household electrical appliances production, consumption and export powerhouse.
At present, many domestic air-conditioner manufacturers are conducting research conditioner reliability, the reliability of test methods for air conditioners in particular be
Research. In view of this situation, it is necessary to develop "household and similar use room air conditioner reliability test methods" national standards, thereby
Reliability test method for the air conditioner to regulate the industry and guidance.
Household and similar room air conditioner
Reliability Test Methods
1 Scope
This standard specifies the household and similar use room air conditioner (hereinafter referred to as an air conditioner) Reliability Qualification and Reliability Acceptance Test
Test requirements, test implementation, fault analysis and statistics, determination, recording and reporting test test test results and the like.
This standard applies to air-cooled condensers, Hermetic motor - compressors for household and similar use room air conditioner.
Reliability Test Methods for other similar products available for implementation.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2422 electric and electronic products environmental testing terminology (GB/T 2422-1995, eqv IEC 60068-5-2.1990)
GB/T 2900.13 Electrotechnical terminology credibility and quality of service (GB/T 2900.13-2008, IEC 60050 (191).1990,
Amend.1.1999AndAmend.2.2002, IDT)
GB/T 5080.1 Equipment reliability testing - General requirements (GB/T 5080.1-1986, IEC 60605-1. 1978, IDT)
GB/T 5080.7-1986 Equipment reliability testing efficiency constant failure rate assumption under the MTBF of the verification test
Inspection program (IEC 60605-7. 1978, IDT)
3 Terms, definitions and symbols
GB/T 2900.13, GB/T 2422 and GB/T 5080.1 and established in the following terms, definitions and symbols apply to this standard.
3.1 Terms and Definitions
3.1.1
The average time between failures meanoperatingtimebetweenfailures; MTBF
Adjacent average working time between two failures, called MTBF. It only applies to repairable products.
3.1.2
MTBF verification interval demonstratedMTBFinterval
θL, θU
Under the experimental conditions, the possible range of real MTBF, that under the provisions of the confidence interval of MTBF estimate. θU called Confidence
Limit; θL called lower confidence limit.
3.1.3
On MTBF Test Limits uppertestMTBF
θ0
Acceptable MTBF values. When the MTBF of the true value of the product is close to θ0, the test program with a high probability of receiving product.
3.1.4
Lower MTBF Test Limits lowertestMTBF
θ1
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24985-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 24985-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24985-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24985-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|