US$354.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24793-2009: Photography -- Processing wastes -- Determination of silver content Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24793-2009 | English | 354 |
Add to Cart
|
3 days [Need to translate]
|
Photography -- Processing wastes -- Determination of silver content
| Valid |
GB/T 24793-2009
|
PDF similar to GB/T 24793-2009
Basic data | Standard ID | GB/T 24793-2009 (GB/T24793-2009) | | Description (Translated English) | Photography -- Processing wastes -- Determination of silver content | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G84 | | Classification of International Standard | 37.040.30 | | Word Count Estimation | 18,174 | | Date of Issue | 2009-12-15 | | Date of Implementation | 2010-06-01 | | Quoted Standard | GB/T 12806-1991; GB/T 12808-1991; GB/T 6682-2008; ISO 385-2005; ISO 835-2007; ISO 4788-2005; ISO 5667-1-2006; ISO 5667-3-2003; ISO 6353-1-1982; ISO 6353-2-1983; ISO 6353-3-1987 | | Adopted Standard | ISO 10348-1993, IDT | | Regulation (derived from) | National Standard Approval Announcement 2009 No.15 (Total No.155) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the method of analysis and testing of silver in photographic processing waste, including sampling, sample preservation and analysis. |
GB/T 24793-2009: Photography -- Processing wastes -- Determination of silver content---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Photography.Processing wastes.Determination of silver content
ICS 37.040.30
G84
National Standards of People's Republic of China
GB/T 24793-2009/ISO 10348.1993
Determination of silver content photographic processing waste
(ISO 10348.1993, IDT)
Posted 2009-12-15
2010-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is identical with ISO 10348.1993 "Determination of silver content photographic processing waste liquid" (in English).
This standard is equivalent to translate ISO 10348.1993.
For ease of use, this standard made the following editorial changes.
a) "this International Standard" be replaced by "this standard";
b) use a decimal point instead of a decimal comma ",". ",";
c) Delete ISO 10348.1993 Foreword instead of the standard "foreword"; the introduction of the direct translation as a standard introduction.
d) Since the original standard ISO 10348. most have new standards referenced in the 1993 version of normative references. either merge
Or abolished, so this standard when referring to these standards, using the latest version. Specific changes are as follows.
1) ISO 385-1. 1984 Laboratory glassware Burettes - Part 1. General requirements
To. ISO 385.2005 Laboratory glassware Buret
2) ISO 648. 1977 Laboratory glassware single reticle pipette
Read. GB/T 12808-1991 laboratory glassware single marking pipette
3) ISO 835-1. 1981 Laboratory glassware indexing pipettes - Part 1. General requirements
ISO 835-2. 1981 Laboratory glassware indexing pipettes - Part 2. Not regulated pipette tube time
ISO 835-3. 1981 Laboratory glassware indexing pipette Part 3. 15s predetermined waiting time pipette
ISO 835-4. 1981 Laboratory glassware indexing pipette Part 4. blowout pipettes (defunct)
To. ISO 835.2007 Laboratory glassware indexing pipette
4) ISO 1042. 1983 laboratory glassware single marking flask
Read. GB/T 12806-1991 laboratory glassware single marking flask
5) ISO 3696. 1987 specifications and test methods of laboratory water analysis
Read. GB/T 6682. specifications and test methods for laboratory water analysis 2008
6) ISO 4788. 1980 laboratory glassware graduated cylinder
To. ISO 4788.2005 laboratory glassware graduated cylinder
7) ISO 5667-1. 1980 Water quality - Sampling - Part 1. Sampling Program Design Guidelines
ISO 5667-2.1991 Water quality - Sampling - Part 2. Sampling Techniques Guide (defunct)
ISO 5667-3.1994 Water quality - Sampling - Part 3. preservation and handling of samples guidance
To. ISO 5667-1.2006 Water quality - Sampling - Part 1. Sampling procedures and sampling techniques design guidelines
ISO 5667-3.2003 Water quality - Sampling - Part 3. preservation and handling of water samples Guidelines
Appendix A of this standard is a normative appendix.
The standard proposed by China Petroleum and Chemical Industry Association.
The photosensitive material standard by the National Standardization Technical Committee (SAC/TC102) centralized.
This standard was drafted. China Lucky Film Group Corporation.
Drafters of this standard. Cao Yongli, Baoli Min.
GB/T 24793-2009/ISO 10348.1993
Introduction
This standard is one of the special photographic processing waste liquid series of standards for analysis; contains a photographic processing waste liquid silver content analysis and testing
method.
Analysis of photographic processing waste and emissions in the silver content, which faced unique problems in sample collection, processing and analysis. These ones
The problem is not fully included in the standard file, the present development of standards that is provided for this set of methods. Listed in the course of a test
These chemicals corrosive, toxic or other hazards. A clear warning, caution and danger warning has been specified, regardless of any additional
Chemicals should be standard throughout the implementation of preventive measures requirements.
As for waste emissions, best photographic processing plants to establish rules to be managed by the appropriate chemical analysis. Sometimes the analysis chamber is
It allowed, but usually require sampling and analysis outside the wash plant.
Photographic processing waste liquid silver soluble sulfate form or other complex form, but it is a waste of other
Interaction points, generating an unstable system. This system comprises a number of structurally different soluble silver. Analysis of heavy metals in waste samples
Products are generally stabilized by acidified with nitric acid. This treatment method for the analysis of photographic processing waste liquid silver is unsatisfactory. because
Sulphate sulfur labile in an acidic solution, the processing routine is actually promotes the formation of insoluble silver. Cyanide iodide solution is that these waste
Liquid silver effectively protecting agent).
The criteria include flame atomic absorption spectrometry (AAS) and iodide potentiometric titration (PT) two analytical methods. Different
Analysis will determine the different sample preservation and processing methods. Once the sample is fixed iodide, cyanide solution, usually AAS analysis sample
Goods. The iodide titration requires digestion to dissolve silver, and accompanied by the removal of the concentrated sample was boiled in step (Digestion A) caused by interference
Su. Standard AAS method recommended digestion method with hydrochloric acid, does not apply to the preparation of the samples analyzed in silver.
GB/T 24793-2009/ISO 10348.1993
Determination of silver content photographic processing waste
1 Scope
This standard specifies the method of analysis and testing photographic processing waste liquid silver content, including sampling, sample preservation and analysis.
We give support two methods of analysis of three steps.
a) Flame Atomic Absorption Spectrometry (AAS);
b) two kinds iodide potentiometric titration (PT).
Select a sample processing method depends on the analysis method and the constituents of the sample. When the chosen method of analysis by AAS iodide, cyanide treatment
Or preserved samples can be analyzed directly. When selecting PT method is given by Two Digestion way. A digestion method for low-salt waste samples,
Digestion B is suitable for samples containing high solids content.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 12806-1991 laboratory glassware single marking flask (eqv ISO 1042. 1983)
GB/T 12808-1991 laboratory glassware single marking pipette (eqv ISO 648. 1977)
GB/T 6682-2008 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD)
ISO 385.2005 Laboratory glassware Buret
ISO 835.2007 Laboratory glassware indexing pipette
ISO 4788.2005 laboratory glassware graduated cylinder
ISO 5667-1.2006 Water quality - Sampling - Part 1. Sampling procedures and sampling techniques design guidelines
ISO 5667-3.2003 Water quality - Sampling - Part 3. preservation and handling of water samples Guidelines
The first part of the 1982 chemical analysis reagent 1.. ISO 6353-1 General test methods
ISO 6353-2. 1983 Reagents for chemical analysis - Part 2. Specification of the first series
ISO 6353-3. 1987 Reagents for chemical analysis - Part 3. Specification of the second series
Principle 3
3.1 Flame atomic absorption spectrometry (AAS)
Silver hollow cathode lamp heating the excitation and emission spectra of the ultraviolet radiation comprising silver atoms band. The silver ions in solution is sucked
Flame, when the light emitted by the mercury lamp flame, silver ions will follow Beer's law relationship between radiation absorption spectrum of silver.
Where.
CAg --- concentration of silver ions;
K --- constant.
Often used to establish the calibration curve method to clear this relationship.
3.2 potentiometric titration analysis (PT)
Iodide solution was titrated with silver ion containing solution, will precipitate silver iodide formed following relationship.
GB/T 24793-2009/ISO 10348.1993
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24793-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24793-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24793-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24793-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|