HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 24194-2024 English PDF

US$919.00 ยท In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 24194-2024: Ferrosilicon - Determination of multi-element contents - Inductively coupled plasma atomic emission spectrometric method
Status: Valid

GB/T 24194: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 24194-2024English919 Add to Cart 7 days [Need to translate] Ferrosilicon - Determination of multi-element contents - Inductively coupled plasma atomic emission spectrometric method Valid GB/T 24194-2024
GB/T 24194-2009English150 Add to Cart 0--9 seconds. Auto-delivery Ferrosilicon - Determination of aluminum, calcium, manganese, chromium, titanium, copper, phosphorus and nickel content - Inductively coupled plasma atomic emission spectrometric method Obsolete GB/T 24194-2009

PDF similar to GB/T 24194-2024


Standard similar to GB/T 24194-2024

GB/T 24583.1   GB/T 24514   GB/T 24198   GB/T 21931.2   

Basic data

Standard ID GB/T 24194-2024 (GB/T24194-2024)
Description (Translated English) Ferrosilicon - Determination of multi-element contents - Inductively coupled plasma atomic emission spectrometric method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H11
Classification of International Standard 77.100
Word Count Estimation 46,496
Date of Issue 2024-05-28
Date of Implementation 2024-12-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 24194-2024: Ferrosilicon - Determination of multi-element contents - Inductively coupled plasma atomic emission spectrometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 77:100 CCSH11 National Standards of People's Republic of China Replaces GB/T 24194-2009 Determination of Multi-element Content in Ferrosilicon Inductively coupled plasma atomic emission spectrometry Released on 2024-05-28 2024-12-01 implementation State Administration for Market Regulation The National Standardization Administration issued

Foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting: This document replaces GB/T 24194-2009 "Determination of aluminum, calcium, manganese, chromium, titanium, copper, phosphorus and nickel contents in ferrosilicon by inductively coupled plasma Compared with GB/T 24194-2009, in addition to structural adjustments and editorial changes, the main technical changes are as follows: a) Added the determination of the content of iron, magnesium, vanadium, niobium, lead, antimony, zirconium and boron (see Chapter 1); b) Added mannitol reagent (see 5:7); c) The sample quantity has been changed (see 8:2, 7:2 of the:2009 edition); d) The preparation of the sample solution has been changed (see 8:4:1, 7:4:1 of the:2009 edition); e) The preparation of the calibration curve solution has been changed (see 8:4:2, 7:4:2 of the:2009 edition); f) Added the presentation of results (see 9:2); g) Repeatability limit and reproducibility limit are used instead of the allowable error (see Chapter 10, Chapter 9 of the:2009 edition): Please note that some of the contents of this document may involve patents: The issuing organization of this document does not assume the responsibility for identifying patents: This document was proposed by the China Iron and Steel Association: This document is under the jurisdiction of the National Technical Committee for Standardization of Pig Iron and Ferroalloys (SAC/TC318): This document was drafted by: Ordos Xijin Mining and Metallurgy Co:, Ltd:, Wuhan Iron and Steel Co:, Ltd:, Qingdao Yuancheng Chuangzhi Technology Co:, Ltd: Company, Inner Mongolia Ordos Electric Power Metallurgical Group Co:, Ltd:, Ulanqab Product Quality Metrology Inspection and Testing Center, Inner Mongolia University of Science and Technology, Guangdong Zhongse Yanda New Materials Technology Co:, Ltd:, Ningxia Ketong New Materials Technology Co:, Ltd:, Qinghai Baitong High Purity Materials Development Co:, Ltd: Development Co:, Ltd:, Tianjin Jingyi Instrument Co:, Ltd:, Qinghai Huasheng Ferroalloy Smelting Co:, Ltd:, Metallurgical Industry Information Standard Research Research Institute: The main drafters of this document are: Ma Ning, Xu Wengao, Liu Peng, Yu Shurong, Cui Yuwen, Fan Lifeng, Wen Zhen, Liu Wei, Li Jie, Yu Weihua, Li Yonglin, Liu Yonglei, Su Jie, Wang Tiancai, Yang Dabin, Zhang Ruipeng, Han Yiting, Wang Jing, Lu Chunsheng, Zhang Chen, Liu Yanting: This document was first published in:2009 and this is the first revision: Determination of Multi-element Content in Ferrosilicon Inductively coupled plasma atomic emission spectrometry Warning---People who use this document should have practical experience in formal laboratory work: This document does not address all possible safety issues: The user is responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated in relevant national laws and regulations:

1 Scope

This document specifies the determination of iron, aluminum, calcium, manganese, chromium, titanium, phosphorus, copper, nickel, Methods for determining magnesium, vanadium, niobium, lead, antimony, zirconium and boron content: This document applies to the content of aluminum, calcium, manganese, chromium, titanium, phosphorus, copper, nickel, magnesium, vanadium, niobium, lead, antimony, zirconium, boron in ferrosilicon and iron in high silicon ferrosilicon The determination range of each element is shown in Table 1: Table 1 Measurement range Analytical element determination range (mass fraction)/% Fe 0:50~3:00 Al 0:005~3:00 Ca 0:005~3:00 Mn 0:005~0:50 Cr 0:005~0:50 Ti 0:005~0:50 P 0:005~0:06 Cu 0:002~0:10 Ni 0:002~0:10 Mg 0:002~0:20 V 0:001~0:20 Nb 0:0005~0:02 Pb 0:0005~0:01 Sb 0:0005~0:01 Zr 0:005~0:05 B 0:0010~0:03

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document: For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 24194-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 24194-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 24194-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 24194-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 24194-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 24194-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.