HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (17 Jan 2026)
Path: Home > GB/T > Page285 > GB/T 21222-2007                   Home > Standard_List > GB/T > Page285 > GB/T 21222-2007

GB/T 21222-2007 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 21222-2007English254 Add to Cart 3 days [Need to translate] Methods for the determination of the lightning impulse breakdown voltage of insulating liquids Valid GB/T 21222-2007

PDF similar to GB/T 21222-2007


Standard similar to GB/T 21222-2007

GB/T 20634.3   GB/T 20632.3   GB/T 20632.2   GB/T 21218   GB/Z 21223.3   GB/T 21221   

Basic data

Standard ID GB/T 21222-2007 (GB/T21222-2007)
Description (Translated English) Methods for the determination of the lightning impulse breakdown voltage of insulating liquids
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K15
Classification of International Standard 29.035.99
Word Count Estimation 13,142
Date of Issue 2007-12-03
Date of Implementation 2008-05-20
Adopted Standard IEC 60897-1987, IDT
Regulation (derived from) China Announcement of Newly Approved National Standards No. 12 of 2007 (No. 112 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies two test methods A and B, is used to assess the hair finish insulating liquids under standard lightning impulse withstand the electric strength. Method A is based on a stepwise testing procedures, under specified conditions to assess the pulse breakdown voltage. Method B is a statistical test used to test the insulating liquid at a given voltage level of the pulse breakdown probability assumptions. Both methods are applicable to unused or used insulating liquids, the viscosity of the liquid should be at 40��C lower than 700 mm2/s. Both methods can be used positive and negative pulses. For liquid sample preparation, as long as it meets the requirements of industrial use, and no special requirements. However, by sample handling before and after tests conducted can indicate how effective treatment. Mainly two methods used to establish assessment pulse electric strength of insulating liquids standard procedures. These programs are used to distinguish between different dielectric fluid, is also used to check the side when changing the manufacturing process or the material of the chemical composition of the liquid changes in turn cause variations in characteristics.

GB/T 21222-2007: Methods for the determination of the lightning impulse breakdown voltage of insulating liquids


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for the determination of the lightning impulse breakdown voltage of insulating liquids ICS 29.035.99 K15 National Standards of People's Republic of China GB/T 21222-2007/IEC 60897. 1987 Lightning impulse breakdown voltage of insulating liquid measuring method (IEC 60897. 1987, IDT) Posted 2007-12-03 2008-05-20 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is identical with IEC 60897. 1987 "lightning impulse breakdown voltage of insulating liquid measuring method" (in English). For ease of use, this standard made the following editorial changes. a) Delete the international standard "foreword"; b) use the decimal symbol '. 'Decimal symbol instead of' '; c) with a number of Arab '2' instead of the Roman number 'Ⅰ, Ⅱ'. The Standard Appendix A, Appendix B is an informative annex. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee of the insulating material (SAC/TC51) centralized. This standard was drafted. Guilin Electrical Apparatus Research Institute, Xi'an Jiaotong University. The main drafters of this standard. Wang Xianfeng, CAO Xiao Long. This standard was first formulated. GB/T 21222-2007/IEC 60897. 1987 Lightning impulse breakdown voltage of insulating liquid measuring method

1 Scope

1.1 standard specifies two test methods A and B, is used to assess the insulating liquid is subjected to standard lightning pulse at divergent field power Gas intensity. A test method is based on a step by step procedure for assessment under specified conditions of impulse breakdown voltage. Method B is a statistical test used to test the insulating liquid at a given voltage pulse breakdown probability assumptions. 1.2 Both methods are applicable to unused or used insulating liquids, the viscosity of the liquid should be at 40 ℃ lower than 700mm2/s. Both methods can use positive and negative pulses. For the preparation of liquid samples, as long as it meets the requirements for industrial use, and no special Provisions. However, before and after the test by sample handling and processing can indicate how effective treatment. 1.3 two methods used to establish standard procedures for assessing the insulating liquid pulsed electric strength. These programs are used to distinguish between different electricity Liquid medium, it can also be used to detect the characteristic changes when a chemical manufacturing process or material changes in the composition of the liquid changes in turn caused.

2 Overview

2.1 insulating liquid for use in electrical equipment may be subjected to lightning or switching frequency sinusoidal instantaneous voltage and the operating voltage superimposed effect. Whether this is a one-way or over-voltage oscillation, the result will be positive or negative polarity of the transient effect, which requires knowledge of Insulating liquid properties under these conditions. However, in order to make the use of needles - pulse test vessel ball shape of the electrodes obtained with the actual breakdown voltage insulation system liquid Consistent performance, but also we need more practical experience. 2.2 in the insulating liquid, pulse breakdown is a complex phenomenon still unclear. It needs to start a pre-breakdown damage (streamer) of And the spread of the process. Breakdown voltage and the following factors. the voltage waveform, the duration of the applied voltage and the electric field distribution. In order to obtain comparable results, all of these factors should be clearly defined and strictly controlled. Nevertheless, the findings are often Results Compared dispersion, this dispersion is always connected and pre-breakdown mechanism related to randomness. 2.3 Although the uniform electric field, the polarity of the voltage breakdown characteristics are not applied, but in a divergent field, the polarity of a significant breakdown characteristics Prominent role, especially for needle - ball-shaped electrode is greater impact. Practice has proved that the electric field distribution, the chemical composition of the liquid Negative pulse breakdown characteristics play a major role. Therefore, in order to identify the chemical composition of the insulating liquid, must be above the two Methods used in the high finish electrode system shape. 2.4 impulse breakdown voltage with the forefront of the delay wave, and therefore the two methods defined in the standard use only full-wave pulses (1.2/50μs). 2.5 with frequency breakdown voltage (IEC 60156) different pin - ball impulse breakdown substantially independent of moisture, particles and other impurities. Thus, as long as Impurity concentration does not exceed the limit use liquid, do not take any preventive measures to control these impurities.

3 Normative References

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 311.6-2005 high voltage test techniques Part 5. Measuring ball gap (IEC 60052.2002, IDT) GB/T 16927.1-1997 high voltage test techniques - Part 1. General Test Technology (eqv IEC 60060-1. 1989) GB/T 16927.2-1997 high voltage test techniques - Part 2. Measuring systems (eqv IEC 60060-2.1994) IEC 60060-3 High voltage test techniques - Part 3. Measuring device GB/T 21222-2007/IEC 60897. 1987



Price & Delivery

US$254.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 21222-2007: Methods for the determination of the lightning impulse breakdown voltage of insulating liquids
Status: Valid

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 21222-2007_English be delivered?

Answer: Upon your order, we will start to translate GB/T 21222-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 21222-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 21222-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information