|
US$639.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21131-2007: Environmental tobacco smoke -- Estimation of its contribution to respirable suspended particles -- Determination of particulate matter by ultraviolet absorbance and by fluorescence Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 21131-2007 | English | 639 |
Add to Cart
|
3 days [Need to translate]
|
Environmental tobacco smoke -- Estimation of its contribution to respirable suspended particles -- Determination of particulate matter by ultraviolet absorbance and by fluorescence
| Obsolete |
GB/T 21131-2007
|
PDF similar to GB/T 21131-2007
Basic data | Standard ID | GB/T 21131-2007 (GB/T21131-2007) | | Description (Translated English) | Environmental tobacco smoke -- Estimation of its contribution to respirable suspended particles -- Determination of particulate matter by ultraviolet absorbance and by fluorescence | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | X85 | | Classification of International Standard | 65.160 | | Word Count Estimation | 16,184 | | Date of Issue | 2007-10-16 | | Date of Implementation | 2008-01-01 | | Adopted Standard | ISO 15593-2001, IDT | | Regulation (derived from) | China National Standard Approval Announcement2007 No.11 (Total No.111) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the environmental tobacco smoke (ETS) to be inhaled particulate matter suspended Shun (RSP) affect the rate of assessment sampling and measurement methods side. |
GB/T 21131-2007: Environmental tobacco smoke -- Estimation of its contribution to respirable suspended particles -- Determination of particulate matter by ultraviolet absorbance and by fluorescence
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 65.160
X85
National Standards of People's Republic of China
GB/T 21131-2007/ISO 15593..2001
Estimation of respirable suspended particulates in environmental tobacco smoke
Determination of Particle Matter by UV Absorption and Fluorescence Spectrometry
(ISO 15593..2001, IDT)
2007-10-16 release
2008-01-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Foreword
This standard is equivalent to the use of international standards ISO 15593..2001 "environmental tobacco smoke inhalable suspended particulate matter with UV absorption
(English version). This standard is equivalent to ISO 15593-2001 in technical content. Normative references
Adopting international standards that have been translated into national standards.
Appendix A to this standard is an informative appendix.
This standard is proposed by the State Tobacco Monopoly Bureau.
This standard is under the jurisdiction of the National Tobacco Standardization Technical Committee (TC144).
The drafting unit of this standard. National Tobacco Quality Supervision and Inspection Center.
The main drafters of this standard. Tang Gangling, Xie Fuwei, Wang, Zhao Le, Liu Huimin.
GB/T 21131-2007/ISO 15593..2001
Introduction
Environmental Tobacco Flue Gas (ETS) is an aerosol consisting of gas phase and particulate matter due to the difference in gas phase and particle properties
Different, resulting in the lack of correlation between the two, and thus accurately evaluate the indoor air environment, the level of tobacco smoke levels need to be measured on both phases are appropriate
In the ideal environment Tobacco flue gas marked with the conditions, the most critical one is the environmental conditions in a certain range,
The indicator must maintain a fairly stable proportional relationship with a contaminant or a class of contaminants (eg, suspended particles) (see reference [1]).
Note. All references cited in the bibliography are provided. For the purpose of providing information to users of this standard, the reference text in the standard text lists the
The source of the literature.
UV particles (UVPM) and fluorescent particles (FPM) meet this requirement, in a variety of ventilation conditions and sampling time with the smoke
(RSP) remained a constant proportional relationship. In contrast, nicotine (environmental tobacco flue gas aerosol gas phase
(ETS-PM) does not maintain a constant proportional relationship with the environmental tobacco smoke particles (see reference [2]).
Inhalable suspended particulates are a very important indicator of the overall mass of air, and it has a variety of sources, such as combustion products
Gas, dust, talc, insecticide dust, viruses, bacteria, etc. (see reference [3].) Thus, respirable suspended particulates are not rings
The study shows that in most of the indoor space allowed to smoke, the average only 50% of the smoke,
Or less respirable suspended particulates are derived from tobacco smoke (see references [4] to [7].) The assay method described in this standard is effective
Reducing the degree of uncontrollable deviations inherent in respirable suspended particulate matter as an environmental tobacco smoke marker method (see reference
[4] ~ [6], [8] ~ [13]).
Because the measured spectral absorption is not unique to the organic tobacco smoke granules, these methods are environmental tobacco smoke
(I.e., an over-high evaluation) of the effects of inhalable suspended particulates
Will significantly increase the measured value of the UV particles (see reference [14]), while the tendency of the fluorescent particles is less obvious, but not
Absolute exclusion of the existence of interference. In short, due to the existence of non-quantifiable interference, so these methods can only provide environmental tobacco smoke on the indoor
A reference to the effects of respirable suspended particulates, rather than absolute values.
GB/T 21131-2007/ISO 15593..2001
Estimation of respirable suspended particulates in environmental tobacco smoke
Determination of Particle Matter by UV Absorption and Fluorescence Spectrometry
1 Scope
This standard specifies the sampling and determination of the effects of environmental tobacco smoke (ETS) on respirable particulate matter (RSP).
2 normative reference documents
The terms of the following documents are incorporated by reference in this standard and are the terms of this standard. Any reference to the date of the document,
(Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard
Whether the latest version of these files can be used, and the most recent version of the referenced document, which is not dated, applies to this standard.
ISO 648 laboratory glassware single standard pipette
ISO 1042 laboratory glassware single line capacity bottle
3 terms and definitions
The following terms and definitions apply to this standard.
3.1
The body has been out of the elbow, has been dilute the mainstream of flue gas and has been aging, dilute the side of the mixture of flue gas.
3.2
When the particle size selective sampling device was used, the trapping efficiency curve with the aerodynamic diameter of 4.0 μm was obtained
particle.
3.3
By comparing the absorbable suspended particulate matter with the UV absorbance of the substitute standard, the tobacco smoke particles can be inhaled
Estimation of the impact rate of suspended particulates.
3.4
By comparing the fluorescence intensity of the sample of the respirable suspended particulate matter with the reference standard, the tobacco smoke particles can be
Estimation of the impact rate of suspended particulates.
3.5
The particulate part of the environmental tobacco smoke.
3.6
Its concentration and the known concentration of environmental tobacco tobacco particulate matter solution has established a quantitative relationship between the chemicals.
For example. UV particles with 2, 2 ', 4, 4'-tetrahydroxybenzophenone (tetrahydroxybenzophenone) (THBP) as a substitute
Standard; fluorescent particles with scopolamine (scopoletin) as a substitute standard.
GB/T 21131-2007/ISO 15593..2001
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 21131-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 21131-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 21131-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21131-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|