|
US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19882.212-2012: Automatic meter reading system -- Part 212: Distribution line carrier meter reading system -- DLC Concentrator Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19882.212-2012 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
Automatic meter reading system -- Part 212: Distribution line carrier meter reading system -- DLC Concentrator
| Valid |
GB/T 19882.212-2012
|
PDF similar to GB/T 19882.212-2012
Basic data | Standard ID | GB/T 19882.212-2012 (GB/T19882.212-2012) | | Description (Translated English) | Automatic meter reading system -- Part 212: Distribution line carrier meter reading system -- DLC Concentrator | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N22 | | Classification of International Standard | 17.220.20 | | Word Count Estimation | 23,260 | | Quoted Standard | GB/T 2423.1-2008; GB/T 2423.2-2008; GB/T 2423.3-2006; GB/T 2423.10-2008; GB/T 2829-2002; GB 4208-2008; GB/T 5169.11-2006; GB/T 15284-2002; GB/T 16935.1-2008; GB/T 17626.2-2006; GB/T 17626.3-2006; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17626.8-2006; GB | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the carrier concentrator (hereinafter referred to as the concentrator) terminology, technical requirements, test methods and inspection rules. This section applies to low-voltage power line carrier meter reading system with a conce |
GB/T 19882.212-2012: Automatic meter reading system -- Part 212: Distribution line carrier meter reading system -- DLC Concentrator ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Automatic meter reading system Part 212. Distribution line carrier meter reading system DLC Concentrator.
ICS 17.220.20
N22
National Standards of People's Republic of China
Automatic meter reading system
Part 212. Low Voltage Power Line Carrier Record System
Carrier concentrator
Part 212. Distributionlinecarriermeterreadingsystem-
DLCConcentrator
Issued on. 2012-12-31
2013-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 2 Technical Requirements
4.1 climatic and atmospheric conditions 2
4.2 Power supply 3
3 4.3 Structure
4.4 Mechanical properties 5
4.5 insulation performance 5
4.6 communication channel 5
4.7 functional and performance requirements 6
4.8 collect data reliability 8
4.9 Electromagnetic Compatibility Requirements 8
4.10 reliability index 9
5 Test methods 9
5.1 Test conditions 9
5.2 Structure and mechanical tests 9
5.3 Climate Impact Test 10
5.4 insulation test 10
5.5 Power Supply Effect Test 11
5.6 Test transmission channel 12
12 5.7 functionality and performance test
5.8 Electromagnetic compatibility test 13
14 5.9 Reliability test
15 6 Inspection Rules
6.1 Inspection classification 15
6.2 factory inspection 15
6.3 Type tests 15
6.4 Project and order 16
7 signs, transportation and storage 16
7.1 marks 16
7.2 Transport 17
7.3 Storage 17
Appendix A (informative) concentrator and collector type identification code 18
Annex B (informative) test items and the order of 19 recommendations
Foreword
"Low-voltage power line carrier meter reading system" is divided into four parts.
--- Part 211. System requirements;
--- Part 212. Carrier concentrator;
--- Part 213. Carrier collector;
--- Part 214. static energy meter carrier special requirements.
Concentrator".
Listed below "Automatic meter reading system" and the promulgation of national standards with international standards is expected and the corresponding structure.
a) GB/T 19882.1-2005 "General automatic meter reading system";
b) "automatic meter reading system meter reading system".
--- Part 21. Low-voltage power line carrier meter reading system;
--- Part 22. Wireless communication meter reading system;
--- Part 23. IP-based network meter reading system;
c) "automatic meter reading system application layer data exchange protocol".
--- Part 31. Object identification system (GB/T 19882.31-2007, IEC 62056-61.2002, IDT);
--- Part 32. Interface classes (GB/T 19882.32-2007, IEC 62056-62.2002, IDT);
--- Part 33. COSEM application layer (GB/T 19882.33-2007, IEC 62056-53.2002, IDT);
d) GB/T 19897-2005 "Automatic Meter Reading System Lower Layer Communication Protocol".
--- Part 1. Direct local data exchange (GB/T 19897.1-2005, IEC 62056-21.2002, IDT);
--- Part 2. Use twisted pair LAN-based carrier signal (GB/T 19897.2-2005, IEC 62056-31.
1999, IDT);
--- Part 3. physical layer connection-oriented service processes asynchronous data exchange (GB/T 19897.3-2005,
IEC 62056-42.2002, IDT);
--- Part 4. Based on the HDLC protocol link layer (GB/T 19897.4-2005, IEC 62056-46.2002, IDT).
This section drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This part is proposed by China Machinery Industry Federation.
This part of the National Electrical Instrument Standardization Technical Committee (SAC/TC104) centralized.
This section is responsible for drafting unit. Harbin Electrical Instrument Research Institute, Beijing Fuxing Xiaocheng Electronic Technology Co., Ltd., Beijing Nath electricity
Co., Ltd, Jiangsu Lin Yang Electronics Co., Ltd., Shenzhen Clou Electronics Technology Co., Ltd., Changsha Weisheng Information Technology Co.,
Xi'an flags Electronics Co., Ltd.
Participated in the drafting of this section. Terry Shenzhen Jie Electronics Co., Ltd. Shenzhenshilong Power Electric Co., Ltd. Hangzhou PAX Electronic Technology
Ltd. ﹑ Shenzhen HND Instrumentation Co., Ltd., Holley Instrument Group Co., Ltd., Ningbo Samsung Technology Co., Tengen
Group Co., Ltd., Heilongjiang Electric Power Co., Ltd., North China Electric Power Research Institute Co., Ltd., Guangdong-ho Di Innovation and Technology Co.,
Division, Shenzhen City of Microelectronics Co., Ltd. Huaihua Jiannan Machinery Co., Ltd., Zhangzhou Branch Electric Co., Ltd. Shanghai ﹑ EF special Electronics
Technology Co., Ltd., Qingdao Neusoft Computer Technology Co., Ltd. Echelon.
The main drafters of this section. Zhang Zhizhong, Pan Kai, Liwan Hong, Xue Xiaowei Feng ﹑ Germany Jin, Zhou Jin Jiang, the blue iron rock, Yuanrui Ming, Guan Wenju,
And glue, Guo Yonglin, Xu Maolin, HU students, Yang Wu, Song Xijiang, Yao this ceremony, Chen Sheng-Rong ﹑ Li Hong, Zhang Shaoheng, easy to think of apricot, Liu Yongsheng.
Automatic meter reading system
Part 212. Low Voltage Power Line Carrier Record System
Carrier concentrator
1 Scope
This section provides the carrier concentrator (hereinafter referred to as concentrators) terminology, technical requirements, test methods and inspection rules.
This section only applies to low-voltage power line carrier meter reading system with a concentrator.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold (IEC 60068-2-
1.2007, IDT)
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat (IEC 60068-2-
2.2007, IDT)
GB/T 2423.3-2006 Environmental testing for electric and electronic products Part 2. Test methods - Test Cab. Damp heat test
(IEC 60068-2-78.2001, IDT)
GB/T 2423.10-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Fc. Vibration (sinusoidal) (IEC
60068-2-6.1995, IDT)
GB/T 2829-2002 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT)
GB/T 5169.11-2006 Fire hazard testing for electric and electronic products - Part 11. Glowing/hot-wire based test methods to
Glow-wire flammability test method for products (IEC 60695-2-11.2000, IDT)
GB/T 15284-2002 tariff applications special requirements
GB/T 16935.1-2008 within low-voltage systems Insulation coordination for equipment - Part 1. Principles, requirements and tests (IEC 60664-1.
2007, IDT)
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.2001,
IDT)
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4-
3.2002, IDT)
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test (IEC 61000-
4-4.2004, IDT)
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test (IEC 61000-4-5.
2005, IDT)
GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test (IEC 61000-4-8.2001,
IDT)
GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19882.212-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 19882.212-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19882.212-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19882.212-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|