US$209.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19267.6-2008: Physical and chemical examination of trace evidence in forensic sciences -- Part 6: Scanning electron microscope/X ray energy dispersive spectrometry Status: Valid GB/T 19267.6: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19267.6-2008 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Physical and chemical examination of trace evidence in forensic sciences -- Part 6: Scanning electron microscope/X ray energy dispersive spectrometry
| Valid |
GB/T 19267.6-2008
|
| GB/T 19267.6-2003 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Physical and chemical examination of trace evidence in forensic sciences -- Part 6: Scanning electron microscopy
| Obsolete |
GB/T 19267.6-2003
|
PDF similar to GB/T 19267.6-2008
Basic data | Standard ID | GB/T 19267.6-2008 (GB/T19267.6-2008) | | Description (Translated English) | Physical and chemical examination of trace evidence in forensic sciences -- Part 6: Scanning electron microscope/X ray energy dispersive spectrometry | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A92 | | Classification of International Standard | 13.310 | | Word Count Estimation | 9,933 | | Date of Issue | 2008-08-14 | | Date of Implementation | 2009-03-01 | | Older Standard (superseded by this standard) | GB/T 19267.6-2003 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 14 of 2008 (total 127) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the scanning electron microscopy and energy dispersive X-ray inspection method is used in combination. This section applies to the field of criminal techniques and chemical examination of trace evidence, other areas may also refer to the use. |
GB/T 19267.6-2008: Physical and chemical examination of trace evidence in forensic sciences -- Part 6: Scanning electron microscope/X ray energy dispersive spectrometry ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Physical and chemical examination of trace evidence in forensic sciences Part 6. Scanning electron microscope/X ray energy dispersive spectrometry
ICS 13.310
A92
National Standards of People's Republic of China
Replacing GB/T 19267.6-2003
Criminal and chemical examination of trace evidence
Part 6. SEM/X-ray
Spectroscopy
Posted 2008-08-14
2009-03-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 19267 "criminal and chemical examination of trace evidence" is divided into 12 parts.
--- Part 1. Infrared absorption spectrometry;
--- Part 2. UV - visible absorption spectroscopy;
--- Part 3. Molecular Fluorescence Spectroscopy;
--- Part 4. atomic emission spectrometry;
--- Part 5. Atomic absorption spectrometry;
--- Part 6. Scanning electron microscopy/X-ray spectroscopy;
--- Part 7. Gas chromatography - mass spectrometry;
--- Part 8. microscopic spectrophotometry;
--- Part 9. thin layer chromatography;
--- Part 10. gas chromatography;
--- Part 11. High performance liquid chromatography;
--- Part 12. Thermal Analysis.
This section GB/T Part of 619,267.
This Part replaces GB/T 19267.6-2003 "criminal and chemical examination of trace evidence in Part 6. Scanning Electron Microscopy
Mirror method. "
This portion of the GB/T 19267.6-2003 compared to the main changes are.
--- Standard name a "scanning electron microscopy/X-ray spectroscopy";
--- Increasing the term of the environmental electron microscope (this section 3.2,3.18);
--- Increasing the principle part of the environmental electron microscope (this section 4.1);
--- Instrument composed of indicators made the necessary changes (this part of GB/T 19267.6-2003 and Chapter 5 of);
--- Modify the content of the samples prepared (this section 6.4.1,6.4.2, GB/T 19267.6-2003 of 6.3, 6.4);
--- Increased working distance describes the content (in this section 7.2.4);
--- Modify the sample analysis of the content (in this section and GB/T 19267.6-2003 7.3).
This section presents the People's Republic of China Ministry of Public Security.
The criminal section of the National Standardization Technical Committee Physical Testing Standardization Technical Committee (SAC/TC179/SC4)
Centralized.
This section is drafted. Shanghai Public Security Bureau Evidence Identification Center.
The main drafters of this section. Ding Minju, Shao Zhiyuan.
This part of the standard replaces the previous editions are.
--- GB/T 19267.6-2003.
Criminal and chemical examination of trace evidence
Part 6. SEM/X-ray
Spectroscopy
1 Scope
GB/T 19267 provisions of this part of the scanning electron microscope and X-ray spectrometer combined with the test method.
This section applies to the technical field of trace evidence in criminal physical and chemical testing, may also refer to other areas of use.
2 Normative references
The following documents contain provisions which, through reference GB/T 19267 in this section, constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 13966 Analytical Instruments terms
3 Terms and Definitions
GB/T 13966 and established in the following terms and definitions apply to this section.
3.1
Emitted by the electron gun and by electromagnetic lenses focus the electron beam in the magnetic field scanning coils, the sample surface by a certain time, empty
In chronological order as the raster scan (also known as point by point scan), received by the detector samples the secondary electron excitation signal, etc., and then by the photoelectric conversion in significant
To reflect the observed sample surface looks like an electronic representation of an upper display.
3.2
ESEM is a new scanning electron microscope developed in recent years. Conventional SEM sample chamber vacuum level must be better than 10-3Pa, non -
Conductor and water samples need to be plated conductive layer, and ESEM sample chamber through the gas in low vacuum "environment" status (up pressure
To 2600Pa), based on gas ionization and amplification principle, non-conductive and aqueous samples can be treated without the surface conduction can be observed directly.
3.3
Beam bombarding a sample with a substance having a certain energy and intensity, according to the particle energy and intensity of the excited sample substance, or a sample
Reflective material particle energy and intensity of the relationship diagram (called spectrum) of the sample to achieve non-destructive elemental analysis, structural analysis and surface material
Methods of Analysis.
3.4
(SEM/EDS)
Micro-beam electron bombardment of the sample, the sample excitation of micro elements characteristic X-ray detection system displays the characteristics of each element microanalysis X
Ray energy and intensity graph (called spectrum) and their distribution in the surface of the specimen.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19267.6-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 19267.6-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19267.6-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19267.6-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 19267.6-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19267.6-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|