Price & DeliveryUS$264.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 17215.676-2018: Electricity metering data exchange -- The DLMS/COSEM suite -- Part 76: The 3-layer, connection-oriented HDLC based communication profile Status: Valid
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| GB/T 17215.676-2018 | English | 264 |
Add to Cart
|
3 days [Need to translate]
|
Electricity metering data exchange -- The DLMS/COSEM suite -- Part 76: The 3-layer, connection-oriented HDLC based communication profile
| Valid |
Basic data | Standard ID | GB/T 17215.676-2018 (GB/T17215.676-2018) | | Description (Translated English) | Electricity metering data exchange -- The DLMS/COSEM suite -- Part 76: The 3-layer, connection-oriented HDLC based communication profile | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N22 | | Classification of International Standard | 17.220.20 | | Word Count Estimation | 14,180 | | Date of Issue | 2018-12-28 | | Date of Implementation | 2019-07-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 17215.676-2018: Electricity metering data exchange -- The DLMS/COSEM suite -- Part 76: The 3-layer, connection-oriented HDLC based communication profile
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electricity metering data exchange--The DLMS/COSEM suite--Part 76. The 3--layer, connection--oriented HDLC based communication profile
ICS 17.220.20
N22
National Standards of People's Republic of China
Electrical measurement data exchange DLMS/COSEM component
Part 76. HDLC-based connection-oriented
Layer 3 communication configuration
Part 76. The3-layer, connection-orientedHDLCbasedcommunicationprofile
(IEC 62056-7-6.2013, Electricitymeteringdataexchange-
TheDLMS/COSEMsuite-Part 7-6. The3-layer, connection-oriented
HDLCbasedcommunicationprofile, IDT)
2018-12-28 released.2019-07-01 implementation
State market supervision and administration
China National Standardization Administration issued
Content
Foreword I
1 Scope 1
2 Normative references 1
3 Terms, definitions and abbreviations 1
4 communication environment 2
5 Structure of this configuration 2
6 Identification and Addressing Scheme 3
7 Support layer service and service mapping 4
8 DLMS/COSEM application layer communication configuration specific service parameters 5
9 Special considerations and constraints 5
9.1 Confirmed and unconfirmed application connection and data transfer service calls, frame type 5 used
9.2 Application connection and data link connection, release the correspondence between application connections 6
9.3 COSEM-OPEN/-RELEASE/-ABORT Service Parameter 6
9.4 EventNotification Service and Protocol 7
9.5 Long message transmission 8
9.6 Support for multipoint configuration 8
Reference 10
Foreword
GB/T 17215 "AC measuring equipment" is divided into several parts, GB/T 17215.6 "DLMS/COSEM component electrical measurement data
Exchange is divided into the following sections.
--- Part 10. Intelligent Measurement Standardization Framework;
--- Part 11. DLMS/COSEM communication configuration standard template;
--- Part 31. Local area network use based on twisted pair carrier signals;
--- Part 46. Data link layer using HDLC protocol;
--- Part 47. DLMS/COSEM transmission layer based on IP network;
--- Part 53. DLMS/COSEM application layer;
--- Part 61. Object Identification System (OBIS);
--- Part 62. COSEM interface class;
--- Part 73. Wired and wireless M-Bus communication configurations for local and community networks;
--- Part 76. HDLC-based connection-oriented three-layer communication configuration;
--- Part 91. Communication configuration using the WEB service to access the COSEM server via CAS;
--- Part 97. Communication configuration based on TCP-UDP/IP network.
This part is the 76th part of GB/T 17215.6.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section uses the translation method equivalent to IEC 62056-7-6.2013 "Electrical Measurement Data Exchange DLMS/COSEM Components Sections 7-6
Part. HDLC-based connection-oriented Layer 3 communication configuration.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
---GB/T 17215.646-2018 Electrical measurement data exchange DLMS/COSEM components - Part 46. Based on HDLC
Data link layer of the protocol (IEC 62056-46.2002, IDT);
---GB/T 17215.653-2018 Electrical Measurement Data Exchange DLMS/COSEM Components Part 53. DLMS/CO-
SEM application layer (IEC 62056-5-3..2017, IDT);
--- GB/T 19897.1-2005 Automatic meter reading system - Low-level communication protocol - Part 1. Direct local data exchange (IEC 62056-
21.2002, MOD);
--- GB/T 19897.3-2005 Automatic meter reading system - Low-level communication protocol - Part 4. Connection-oriented asynchronous data exchange
Physical layer service process (IEC 62056-42.2002, IDT).
This section has made the following editorial changes.
--- The standard name was changed from part 7-6 to part 76.
Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents.
This part was proposed by the China Machinery Industry Federation.
This part is under the jurisdiction of the National Electrotechnical Instrumentation Standardization Technical Committee (SAC/TC104).
This section drafted by. Harbin Electric Instrument Research Institute Co., Ltd., Yunnan Power Grid Co., Ltd. Electric Power Research Institute, Shenzhen
Kelu Electronic Technology Co., Ltd., State Grid Jiangxi Electric Power Co., Ltd. Electric Power Research Institute, Shenzhen Aerospace Tairuijie Electronics Co., Ltd.
Company, Yantai Dongfang Weston Electric Co., Ltd., China Electric Power Research Institute Co., Ltd., Qingdao Dingxin Communication Co., Ltd., Zhejiang
Chentai Technology Co., Ltd., Huali Technology Co., Ltd., Heilongjiang Electrician Instrumentation Engineering Technology Research Center Co., Ltd.
Ningbo Henglida Technology Co., Ltd., Guangdong Dongfang Telecommunications Technology Co., Ltd.
The main drafters of this section. Shen Xin, He Yongsheng, Guan Wenju, Zhang Dengqing, Zheng Zhenzhou, Yang Di, Zhang Yumeng, Jiang Bin, Chen Wenxin, Tang Yue, Qi Ruipeng,
Sun Binggong, Zeng Shitu, Zhang Xiangcheng, Xie Xizhen, Wang Wei, Guo Wei, Qin Guoxin.
Electrical measurement data exchange DLMS/COSEM component
Part 76. HDLC-based connection-oriented
Layer 3 communication configuration
1 Scope
This part of GB/T 17215.6 specifies HDLC-based connection-oriented DLMS/COSEM three-layer communication configuration.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 62056-21.2002 Electrical measurement data exchange, meter reading, rate and load control - Part 21. Direct local data exchange
(Electricitymeteringdataexchangeformeterreading,tariffandloadcontrol-Part 21.Directlocal
Dataexchange)
IEC 62056-42.2002 Electrical measurement data exchange, meter reading, rates and load control - Part 42. Connection-oriented asynchronous data
Physical layer services and processes exchanged (Electricitymeteringdataexchangeformeterreading,tariffandloadcon-
trol-Part 42. Physicallayerservicesandproceduresforconnection-orientedasynchronousdataex-
Change)
IEC 62056-46.2002 Data exchange for metering, rate and load control - Part 46. s
Data link layer (Electricity metering-Dataexchangeformeterreading, tariffandloadcontrol-Part 46.
DatalinklayerusingHDLCprotocol)
Amendment1.2006
IEC 62056-5-3.2013 Electrical Measurement Data Exchange DLMS/COSEM Components Part 5-3. DLMS/COSEM
Use layer (Electricity meteringdataexchangeTheDLMS/COSEMsuitePart 5-3. DLMS/COSEMapplica-
Tionlayer)
3 Terms, definitions and abbreviations
The following abbreviations apply to this document.
AA. Application Association (ApplicationAssociation);
AARQ. Application Connection Request - one of the ACPDUs of the ACSE (A-AssociateRequest-anAPDU of theACSE);
ACSE. Connection Control Service Element (AssociationControlServiceElement);
AL. Application Layer (ApplicationLayer);
APDU. Application Layer Protocol Data Unit (ApplicationLayerProtocolDataUnit);
ASO. Application Service Object (ApplicationServiceObject);
Client. The site requesting service, in the HDLC-based connection-oriented three-layer communication configuration as the primary station (Astation, asking
forservices.Inthecaseofthe3-layer,COHDLCbasedprofileitisthemasterstation);
.cnf. confirm the service primitive (confirmserviceprimitive);

Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 17215.676-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 17215.676-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 17215.676-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17215.676-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|