US$294.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16510-2008: The requirements for the competence of a radiation processing dosimetry calibration laboratory Status: Valid GB/T 16510: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 16510-2008 | English | 294 |
Add to Cart
|
3 days [Need to translate]
|
The requirements for the competence of a radiation processing dosimetry calibration laboratory
| Valid |
GB/T 16510-2008
|
| GB/T 16510-1996 | English | 519 |
Add to Cart
|
4 days [Need to translate]
|
The requirements for the competence of a radiation processing dosimetry calibration laboratory
| Obsolete |
GB/T 16510-1996
|
PDF similar to GB/T 16510-2008
Basic data | Standard ID | GB/T 16510-2008 (GB/T16510-2008) | | Description (Translated English) | The requirements for the competence of a radiation processing dosimetry calibration laboratory | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A58 | | Classification of International Standard | 17.240 | | Word Count Estimation | 15,119 | | Date of Issue | 2008-09-19 | | Date of Implementation | 2009-08-01 | | Older Standard (superseded by this standard) | GB/T 16510-1996 | | Quoted Standard | GB/T 15481, GB/T 16509, GB/T 16640, ISO 9002, ASTM E 170, ASTM E 177, ASTM E 456, ASTM E 1249, ASTM E 1250 | | Adopted Standard | ISOASTM 51400-2002, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the radiation processing dosimetry calibration laboratory should have the capacity requirements. This capability will ensure that the laboratory can provide accurate and reliable calibration and testing services. Standards for radiation processing dosimetry calibration laboratory in the establishment and implementation of its quality system to use, but also as a certification body for laboratory based authentication and authorization |
GB/T 16510-2008: The requirements for the competence of a radiation processing dosimetry calibration laboratory ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The requirements for the competence of a radiation processing dosimetry calibration laboratory
ICS 17.240
A58
National Standards of People's Republic of China
GB/T 16510-2008/ISO /ASTM51400.2002
Replacing GB/T 16510-1996
Radiation processing dosimetry calibration laboratory competency requirements
(ISO /ASTM51400.2002, Practiceforcharacterizationandperformance
ofahigh-doseradiationdosimetrycalibrationlaboratory, IDT)
Posted 2008-09-19
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is identical with ISO /ASTM51400.2002 "Practice of high-dose radiation dosimetry calibration laboratory features and capabilities" (English
Chinese Version).
For ease of use, this standard made the following editorial changes.
a) in accordance with Chinese custom to write some format has been modified.
b) In Chapter 2, "Normative references" in the referenced international standards ISO and ASTM, etc., who have converted to our standards (including
Metrology regulations), the reference to our standards.
c) Remove the informative Appendix A, increased by reference.
This standard replaces GB/T 16510-1996 "Radiation processing dosimetry calibration laboratory capacity requirements."
This standard and GB/T 16510-1996 compared to the main changes are as follows.
--- In the "meaning and purpose" Zhang added "activities in the calibration laboratory to meet the GB/T 15481 General requirements also
Should meet GB/T 15481 and ISO 9000 series of standards requirements; when it acts as a manufacturers calibration results, further
It should include the ISO 9002 standard for assurance model requirements. "Content provisions (Chapter 4 of the 1996 version; this version 4.4);
--- In the universal "meaning and purpose" chapter added "engaged in specific areas of calibration laboratories should also GB/T 15481 of
Supplementary requirements and instructions. "Requirements (Chapter 4 of the 1996 edition; edition 4.5);
--- Were given to "special areas of ionizing radiation calibration laboratory" and "application γ-rays, electron beam and X-ray (bremsstrahlung)
And other particle types of ionizing radiation calibration laboratory dedicated field "additional requirements and instructions chapter (Chapter 6, 1996 edition; edition
Chapter 6 and Chapter 7);
--- The 1996 edition of "absorbed dose measurements laboratory calibration device is compared with the corresponding national standards, the deviation should be 3% in persons
Inside "with" absorbed dose measurements laboratory calibration device is compared with the corresponding national standards, the deviation shall be 5% in persons
Inside. "(See the 1996 version 6.3.6; this version 7.4);
--- Part equipment requirements. A "span calibration laboratory should establish coverage, after examination certified reference standards and transfer standards
Dosimetry system "requirements; deleted 6.6.4.1,6.6.4.2,6.6.4.3,6.6.4.4,6.6.4 1996 edition. 5 and
6.6.4.6 Specific instrument metrological characteristics of the main requirements for content (see the 1996 version 6.6.4; this version 6.8);
--- Adjust the content of "Measurement Uncertainty" chapter (see Chapter 7, 1996 Edition; Chapter 8 edition);
--- Remove the 1996 version of Appendix A, increased by reference.
The standard proposed by China National Nuclear Corporation.
This standard by the National Standardization Technical Committee of nuclear energy.
This standard was drafted. China Institute of Metrology.
The main drafters. Zhang Yanli, Gong Xiaoming, Zhang Hui.
This standard replaces the standards previously issued as follows.
--- GB/T 16510-1996.
GB/T 16510-2008/ISO /ASTM51400.2002
Radiation processing dosimetry calibration laboratory competency requirements
1 Scope
This standard specifies the radiation processing dosimetry calibration laboratory should have the capacity requirements. This capability will ensure that the laboratory can provide accurate
Reliable calibration and testing services. Standards for radiation processing dosimetry calibration laboratory in the establishment and implementation of its quality system, can also be
As a certification body for laboratory authentication and authorization basis.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 15481 testing and calibration laboratories General requirements (GB/T 15481-2000, ISO /IEC 17025.1999,
IDT)
GB/T 16509 doses of radiation processing of Measurement Uncertainty guidelines (GB/T 16509-2008, ISO /ASTM51707.2005,
IDT)
Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is (GB/T 16640-2008, ISO /ASTM51261.2002,
IDT)
ISO 9002 quality system of production, installation and service quality assurance model
ASTME170 radiation dose measurement and academic language
Use ASTME177 material properties testing precision and bias in terms of practice
ASTME456 volume and statistical terms
Standard tests to reduce the dose of radiation damage ASTME1249 measurement error using Co-60 radioactive sources silicon electronics
practice
ASTME1250 application ionization chamber radiation damage assessment silicon electronics in the tests again Co-60 irradiator component with low energy γ
Test method
3 Terms and Definitions
ASTME170 and ICRU Report No. 60 and established the following terms and definitions apply to this standard.
3.1
It is measured and recognized as the reference value of the maximum acceptable deviation. Accepted reference value is determined by the national standards.
3.2
Determining relationships between the magnitude of the measurement system is provided by a measure corresponding to the indicated value; the operation should be carried out under specified conditions,
And includes measurement Uncertainty Evaluation.
Note. Measurement criteria include. Standard reference dosimeter, transfer standard dosimeters and dosimeter work.
3.3
The dosimeter, measuring instruments, a dose response calibration curve (or dose response functions) or related procedures and use of reference standards with the composition
To determine the absorbed dose system.
GB/T 16510-2008/ISO /ASTM51400.2002
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16510-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 16510-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 16510-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16510-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 16510-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16510-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|