US$774.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16509-2008: Standard guide for estimating uncertainties in dosimetry for radiation processing Status: Valid GB/T 16509: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 16509-2008 | English | 774 |
Add to Cart
|
4 days [Need to translate]
|
Standard guide for estimating uncertainties in dosimetry for radiation processing
| Valid |
GB/T 16509-2008
|
| GB/T 16509-1996 | English | RFQ |
ASK
|
6 days [Need to translate]
|
Standard guide for estimating uncertainties in dosimetry for radiation processing
| Obsolete |
GB/T 16509-1996
|
PDF similar to GB/T 16509-2008
Basic data | Standard ID | GB/T 16509-2008 (GB/T16509-2008) | | Description (Translated English) | Standard guide for estimating uncertainties in dosimetry for radiation processing | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A58 | | Classification of International Standard | 17.240 | | Word Count Estimation | 39,385 | | Date of Issue | 2008-09-19 | | Date of Implementation | 2009-08-01 | | Older Standard (superseded by this standard) | GB/T 16509-1996 | | Adopted Standard | ISOASTM 51707-2005, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the �� -rays, X-rays < bremsstrahlung > and electron beam radiation dose measurement device possible sources of uncertainty in requiring the use of dosimetry systems for measurement of absorbed dose uncertainty assessment procedures, also define and explains the basic concepts of measurement, evaluation of the measurement volume, " true value " error and uncertainty, uncertainty components provides the evaluation method, these components are given absorbed dose values ??reported for the standard uncertainty the degree of contribution, and gives the combined standard uncertainty of the calculation method and extensions < General > uncertainty methods. Uncertainty components fixed value in accordance with ISO procedures, the standard deviation of precision and no longer use the traditional concept, see Appendix E Sample. |
GB/T 16509-2008: Standard guide for estimating uncertainties in dosimetry for radiation processing ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard guide for estimating uncertainties in dosimetry for radiation processing
ICS 17.240
A58
National Standards of People's Republic of China
GB/T 16509-2008/ISO /ASTM51707.2005
Replacing GB/T 16509-1996
Dose radiation processing Uncertainty Evaluation Guidelines
(ISO /ASTM51707.2005, IDT)
Posted 2008-09-19
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 6 Meaning and Purpose
Concepts 5 Basic Concepts Uncertainty --- 7
Evaluation of standard uncertainty of 6 10
7 Source of Uncertainty 12
8 expression combined standard uncertainty Uncertainty --- 14
9 uncertainty of the information provided in 15
Appendix A (informative) Uncertainty of calibration data fitting 16
Annex B (informative) conventionally used to introduce uncertainty 19
Annex C (informative) law of propagation of uncertainty 21
Annex D (informative) using a 4034 red Perspex dose measurement based on its own calibration routine Uncertainty Example 22
Annex E (informative) using cerium sulfate - cerous dosimeter transfer standard in the industry with the irradiation device calibration and use of work
Uncertainty dosimeter example 30
References 35
GB/T 16509-2008/ISO /ASTM51707.2005
Foreword
This standard is identical with ISO /ASTM51707.2005 (E) "dose radiation processing Uncertainty Evaluation Guidelines" (in English).
For ease of use, this standard made the following editorial changes.
a) according to the Chinese custom for some formatting has been modified.
b) for ISO /ASTM51707. other international standards cited in 2005 have been adopted as the equivalent of a standard, this standard with
References of these national standards or industry standards corresponding to international standards in place, the rest not tantamount to the adoption of the standards of China
International standards in this standard are a direct reference.
c) the original number of international standards Appendix A1, A2, A3, A4, A5 to A, B, C, D, E.
This standard replaces GB/T 16509-1996 "dose radiation processing of Measurement Uncertainty Guide." This standard and GB/T 16509-
The main changes compared to 1996 are as follows.
--- Adjust some terms and definitions (see Chapter 3, 1996 edition; the first edition chapter 3);
--- Redefined the standard "meaning and purpose" (1996 version 4.1; this edition 4.1,4.2,4.3,4.4,4.5);
--- Increase the role of uncertainty components based on the classification and classification (see 6.1.1.1,6.1.1.2,6.1.1.3,6.1.1.4) ;
--- Increasing the uncertainty of A Class Evaluation Example (see this edition 6.2.4);
--- Increasing the provision and analysis of dosimeter measurement system calibration (see section 7.3 and 7.4 of this edition);
--- Increasing the different calibration methods of uncertainty analysis (see this edition 7.5,7.6,7.7);
--- Increased uncertainty components assessment purposes (see this edition 9.3);
--- Adjust the entire contents of the appendix (see 1996 edition A; Excerpts Appendix A, B, C, D, E);
--- Remove the 1996 version of Appendix B "Bibliography", add "References."
The Standard Appendix A, Appendix B, Appendix C, Appendix D and Appendix E is an informative annex.
The standard proposed by China National Nuclear Corporation.
This standard by the National Standardization Technical Committee of nuclear energy.
This standard was drafted. China Institute of Metrology, Shanghai Jinpeng source of radiation Technology Co., Ltd.
The main drafters. Zhang Hui, Zhang Yanli, Wang Chunyan, Mian Liu Zhi, Zheng Bin.
This standard replaces the previous standard release case. GB/T 16509-1996.
GB/T 16509-2008/ISO /ASTM51707.2005
Dose radiation processing Uncertainty Evaluation Guidelines
1 Scope
practice
Report No. ICRU14 radiation dosimetry. the maximum photon energy 0.6MeV ~ 25MeV X-rays and γ-rays
Report No. ICRU17 radiation dosimetry. a tube voltage of 5kV ~ 150kV X-ray generating means
Report No. ICRU34 pulsed radiation dosimetry
Report No. ICRU35 initial energy of electron beam radiation dose 1MeV ~ 50MeV school
Report No. ICRU37 electrons and positrons stopping power
GB/T 16509-2008/ISO /ASTM51707.2005
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16509-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 16509-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 16509-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16509-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 16509-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 16509-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|