US$274.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25439-2010: Standard method for using cellulose triacetate dosimetry system to measure absorbed dose Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 25439-2010 | English | 274 |
Add to Cart
|
3 days [Need to translate]
|
Standard method for using cellulose triacetate dosimetry system to measure absorbed dose
| Valid |
GB/T 25439-2010
|
PDF similar to GB/T 25439-2010
Basic data | Standard ID | GB/T 25439-2010 (GB/T25439-2010) | | Description (Translated English) | Standard method for using cellulose triacetate dosimetry system to measure absorbed dose | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A58 | | Classification of International Standard | 17.240 | | Word Count Estimation | 14,169 | | Date of Issue | 2010-11-10 | | Date of Implementation | 2011-05-01 | | Quoted Standard | GB/T 16509; GB/T 16510; GB/T 16640; ASTM E170; ASTM E177; ASTM E178; ASTM E925; ASTM E958; ICRU 14 Report; ICRU 17 Report; ICRU 34 Report; ICRU 35 Report; ICRU 37 report; ICRU 60 report | | Adopted Standard | ISOASTM 51650-2005, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 8 of 2010 (total 163) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the use of fibrous triacetate (CTA) dosimetry systems measure electron and photon irradiation, the water absorbed dose is represented by nine materials absorb radiation dose and dose distribution operation and testing procedures, CTA dosimeter is a measuring a dose distribution suitable for the work of the dosimeter. This standard specifies the CTA dose measurement system applicable conditions are: a) the absorbed dose range: 10 kGy ~ 300 kGy (electrons and light on), b) absorbed dose rate range |
GB/T 25439-2010: Standard method for using cellulose triacetate dosimetry system to measure absorbed dose ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard method for using cellulose triacetate dosimetry system to measure absorbed dose
ICS 17.240
A58
National Standards of People's Republic of China
Using cellulose triacetate dose
Measuring systems for standard methods absorbed dose
(ISO /ASTM51650.2005, Standardpracticeforuseofacelulose
triacetatedosimetrysystem, IDT)
Issued on. 2010-11-10
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
Meaning and use 3 4
5 dosimetry system 4
6 dosimeter Preparation 4
Calibration of dosimetry systems 7 5
8 Measurement 5
9 General 6
10 environmental and other factors 6
11 record requirements 7
12 7 Measurement Uncertainty
Keywords 7 13
Appendix A (Informative Appendix) CTA film dosimeters infos 8
Reference 9
Foreword
This standard is identical with ISO /ASTM51650.2005 "cellulose triacetate dosimetry system application standards" (in English).
This standard is equivalent translation ISO /ASTM51650.2005.
For ease of use, this standard made the following editorial changes.
--- The standard name is now changed to "the use of cellulose triacetate dosimetry systems for measurement of absorbed dose standard method";
--- In Chapter 2, "Normative references", the referenced ISO and ASTM standards, who have converted to our standards, references to
Our standards;
--- According to the requirements of the standard preparation of some of the formatting to be modified;
--- International standards misprints modification;
--- International standard appendix A has been modified, added other CTA film dosimeters information, delete the international standards
Appendix A for information about photometer.
Appendix A of this standard is the data appendix.
The standard proposed by China National Nuclear Corporation.
This standard by the National Standardization Technical Committee on Nuclear Energy (SAC/TC58) centralized.
This standard was drafted. China Institute of Atomic Energy.
The main drafters of this standard. Wu Changping, Lin Min, Chenke Sheng, Ye Hongsheng, Xu Lijun, Li Jinying.
Using cellulose triacetate dose
Measuring systems for standard methods absorbed dose
1 Scope
1.1 standard specifies the use of cellulose triacetate (CTA) dosimetry systems for measuring electron and photon radiation, water absorbent Scale
Shown is absorbed radiation dose and dose distribution in the material handling and testing procedures. CTA dosimeter is a suitable dose distribution measurement
Work dosimeter.
1.2 CTA standard dosimetry system suitable conditions.
a) absorbed dose range. 10kGy ~ 300kGy (electrons and photons).
b) absorbed dose rate range. 3Gy · s-1 ~ 4 × 1010Gy · s-1.
c) electron irradiation energy range. 0.2MeV ~ 50MeV.
d) radiation photon energy range. 0.1MeV ~ 50MeV.
e) dosimeter irradiation temperature range. -10 ℃ ~ 70 ℃.
1.3 This standard does not involve security issues associated with its use. Users of this standard is responsible for establishing the applicable safety and health standards and make
Before use to determine its limits applicable.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 16509 doses of radiation processing of Measurement Uncertainty guidelines (GB/T 16509-2008, ISO /ASTM51707.
2005, IDT)
GB/T 16510 radiation processing dosimetry calibration laboratory competency requirements (GB/T 16510-2008, ISO /ASTM51400.
2002, IDT)
Selection and calibration of the guide GB/T 16640 dosimetry systems for radiation processing is (GB/T 16640-2008, ISO /
ASTM51261.2002, IDT)
The term ASTME170 radiometry and dosimetry
Determination ASTME177 material properties in terms of precision and accuracy of application profiles
ASTME178 deviation observed value processing specification
ASTME925 narrow pass band regularly calibrated spectrophotometer specification
ASTME958 UV - Vis spectral bandwidth for measurement of actual
Report No. ICRU14 radiation dosimetry. the maximum photon energy between 0.6MeV ~ 50MeV X-rays and γ-rays
X-ray voltage between 5kV ~ 150kV produced. Report No. ICRU17 radiation dosimetry
Report No. ICRU34 pulsed radiation dosimetry
Report No. ICRU35 radiation dosimetry. energy between 1MeV ~ 50MeV electron beam
Report No. ICRU37 electrons and positrons stopping power
Report No. ICRU60 basic Ionizing Radiation Quantities and Units
3 Terms and Definitions
ASTME170 and No. ICRU60 report and established the following terms and definitions apply to this standard.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25439-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25439-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 25439-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25439-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|