| US$579.00 · In stockDelivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
 GB/T 15043-2008: Method of measuring electrical and photometric characteristics for incandescent lamps
 Status: Valid
 GB/T 15043: Evolution and historical versions
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| GB/T 15043-2008 | English | 579 | Add to Cart | 5 days [Need to translate] | Method of measuring electrical and photometric characteristics for incandescent lamps | Valid | GB/T 15043-2008 |  
			| GB/T 15043-1994 | English | 519 | Add to Cart | 4 days [Need to translate] | Methods for measuring electrical and luminous parameters of incandescent lamps | Obsolete | GB/T 15043-1994 |  
	 
       PDF similar to GB/T 15043-2008 
 Basic data             | Standard ID | GB/T 15043-2008 (GB/T15043-2008) |           | Description (Translated English) | Method of measuring electrical and photometric characteristics for incandescent lamps |           | Sector / Industry | National Standard (Recommended) |           | Classification of Chinese Standard | K71 |           | Classification of International Standard | 29.140.20 |           | Word Count Estimation | 25,219 |           | Date of Issue | 2008-04-29 |           | Date of Implementation | 2008-12-01 |           | Older Standard (superseded by this standard) | GB/T 15043-1994 |           | Quoted Standard | GB/T 2900.65; GB/T 7922-2003 |           | Regulation (derived from) | Announcement of Newly Approved National Standards No. 6 of 2008 (total 119) |           | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |           | Summary | This standard specifies the incandescent light bulb electrical parameters and the total luminous flux, luminous intensity, spatial distribution of luminous intensity, color temperature (hereinafter referred to as luminous flux, luminous intensity distribution of light intensity and color temperature) measurement systems and methods of measurement. This standard applies to tungsten incandescent light bulb as a light emitting material. This standard does not apply to standard light bulbs and bulb with spectral selectivity and with spectrally selective reflective type of incandescent bulbs. | GB/T 15043-2008: Method of measuring electrical and photometric characteristics for incandescent lamps---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 Method of measuring electrical and photometric characteristics for incandescent lamps
ICS 29.140.20
K71
National Standards of People's Republic of China
Replacing GB/T 15043-1994
Incandescent lamps parameter measurement method
Posted 2008-04-29
2008-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
 Table of ContentsIntroduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 measuring system 2
5 measurement procedures and calculation methods 7
Appendix A (normative) power supply and measuring circuit 12
Appendix B (normative) Measurement uncertainty verification system recommended 13
Annex C (normative) recommended integrating sphere coating and formulation 13
Annex D (normative) spectrum CIE standard photometric observer ViewPort function Vp (λ) 14
Appendix E (normative) color correction and absorption correction coefficient calculation 15
Appendix F (Normative Appendix) UCS 16
Slope Annex G (normative) correlated color temperature blackbody locus line and the intersection of the coordinates 17
Annex I (informative) color parameter measurement schematic block diagram 20
1 DC or AC power supply system of FIG. 2
Figure 2 integral flux measurement system diagram 3
Figure 3 spectral method to determine the flux system diagram 4
Figure 4 emission intensity measuring system 5
Figure 5 luminous intensity distribution curve of the measurement system 6
6 red and blue than the color temperature measurement system 6ForewordThis standard replaces GB/T 15043-1994 "incandescent lamps parameter measurement method."
This standard compared with GB/T 15043-1994, the main differences are as follows.
--- The revised standard English;
--- Added "Normative References" chapter;
--- The whole layout and the clauses of the sort;
--- The measure to the red and blue color temperature than the method described in the classical photoelectric law;
--- Adds a new method for measuring the spectral photometric method and so on;
--- Switch integration and spectrometric method to determine the presentation of flux;
--- Adjust the accuracy of detection equipment requirements;
--- Adaptation of the measurement uncertainty verification system recommended method.
The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix H normative appendix I to appendix
Informative appendix.
The standard proposed by China National Light Industry Council.
This standard by the National Standardization Technical Committee of electrical lighting (SAC/TC224) centralized.
This standard was drafted. National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Beijing Lighting Research Institute, Foshan Shunde this state power
Co., Ltd, the National Electric Light Source Quality Supervision and Inspection Center (Beijing).
The main drafters of this standard. Lu Rong tree, I'm following the steel, Zhao Xiurong, Jiang Shan, CAI dry strength, para Yan Fang.
This standard was first published in 1994, this is the first revision.
Incandescent lamps parameter measurement method1 ScopeThis standard specifies the electrical parameters of incandescent bulbs and the total luminous flux, luminous intensity, spatial distribution of luminous intensity, color temperature (hereinafter referred to as luminous flux
The amount of light intensity distribution of the light intensity and color temperature) of the measuring system and the measurement method.
This standard applies to metallic tungsten incandescent light bulb as a light emitting material.
This standard does not apply to standard light bulbs and bulb with a spectrally selective and spectrally selective reflective type with incandescent bulbs.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2900.65 Electrotechnical terminology Lighting (GB/T 2900.65-2004, IEC 60050-845. 1987, MOD)
GB/T 7922-2003 lighting color measurement method3 Terms and DefinitionsGB/T 2900.65 determined and the following terms and definitions apply to this standard.
3.1
Light flux emitted in 4π space. Unit. lumen (lm).
3.2
Is used to replicate and maintain the total luminous flux units --- lumens (lm) value and transfer value and the relative method for measuring the total flux source
Standard measuring tool.
3.3
Luminous flux in a predetermined direction solid angle. Unit. candela (cd).
3.4
Light source in the direction of a predetermined solid angle range of luminous intensity. Unit. candela (cd).
3.5
Light emitted by the light color products (light color) and the same at a temperature blackbody chromaticity, when the absolute temperature of the blackbody is called the light source
Color temperature. Referred to as "color temperature." Unit. Kelvin (K).
3.6
Distribution (color) temperature standard lamp is to save and transfer profile (color) temperature values \u200b\u200bof standard measuring instruments. Luminescent properties can be stabilized
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15043-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 15043-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15043-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15043-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15043-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15043-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.    |