HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 13072-2010 English PDF

US$229.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 13072-2010: Geological water samples -- Determination of radioactive ratio 226Ra/228Ra -- Emanation-β counting techniques
Status: Valid

GB/T 13072: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 13072-2010English229 Add to Cart 3 days [Need to translate] Geological water samples -- Determination of radioactive ratio 226Ra/228Ra -- Emanation-β counting techniques Valid GB/T 13072-2010
GB/T 13072-1991English399 Add to Cart 3 days [Need to translate] Method for measuring the activity ratios of Ra226 to Ra228 in geological water samples Obsolete GB/T 13072-1991

PDF similar to GB/T 13072-2010


Standard similar to GB/T 13072-2010

GB/T 17766   YS/T 514.1   MT/T 1091   GB/T 14157   GB/T 13073   GB/T 13071   

Basic data

Standard ID GB/T 13072-2010 (GB/T13072-2010)
Description (Translated English) Geological water samples -- Determination of radioactive ratio 226Ra/228Ra -- Emanation-�� counting techniques
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard D14
Classification of International Standard 73.020
Word Count Estimation 10,161
Date of Issue 2010-11-10
Date of Implementation 2011-02-01
Older Standard (superseded by this standard) GB/T 13072-1991
Quoted Standard GB/T 6379.1; GB/T 6379.2; GB/T 6379.4; GB/T 6379.5; GB/T 6379.6; GB 9133; GB 14500
Regulation (derived from) National Standard Approval Announcement 2010 No.8 (Total No.163)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the method of analysis of water samples 226Ra/228 Ra geological radioactivity ratio. Which, 226Ra measured by emanation, 228Ra through its daughter 228Ac measurements on low background �� devices. This standard applies to surface water, groundwater, analysis of uranium and uranium mine water plant wastewater 226Ra/228Ra radioactivity ratio, environmental sewage, sea water and solid samples after appropriate treatment may also refer to the use.

GB/T 13072-2010: Geological water samples -- Determination of radioactive ratio 226Ra/228Ra -- Emanation-β counting techniques


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Geological water samples. Determination of radioactive ratio 226Ra/228Ra. Emanation-β counting techniques ICS 73.020 D14 National Standards of People's Republic of China Replacing GB/T 13072-1991 Geological water samples 226Ra/228Ra radioactivity Ratio determination emanation method -β law Issued on. 2010-11-10 2011-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 13072-1991 "geological water samples activity ratio analysis 226Ra/228Ra of." This standard compared with GB/T 13072-1991, the main changes are as follows. --- A standard specification title; --- Increased alert, warnings; --- Provision increases the processing of waste; --- Deleted directory; --- Simplifies the measuring instruments; --- Corrected some errors. The standard proposed by the People's Republic of China Ministry of Land Resources. This standard by the National Standardization Technical Committee of Land and Resources. This standard is drafted by. National Geological Experimental Test Center. This standard was drafted. Nuclear Industry Beijing Institute of Geology. The main drafters of this standard. Wu Zhaohui, Li-kun. This standard replaces the standards previously issued as follows. --- GB/T 13072-1991. Geological water samples 226Ra/228Ra radioactivity Ratio determination emanation method -β law Warning --- personnel should use this standard practice regular laboratory work. This standard does not point out all possible security asked question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.

1 Scope

This standard specifies the method for the analysis of geological water samples 226Ra/228Ra ratio of radioactivity, which, 226Ra measured by emanation, 228Ra 228Ac measured on a low background β by means of its daughter. This standard applies to surface water, groundwater, uranium and uranium mine water plant Wastewater 226Ra/228Ra radioactivity ratio analysis, environmental Sewage, water and solid samples after appropriate treatment can also refer to use. Measuring range. 226Ra specific activity > 3.6 × 10-3Bq/L and 228Ra specific activity > 3.5 × 10-3Bq/L or more of a variety of ratios.

2 Normative references

The following documents contain provisions which, through this standard reference and become the standard terms. For dated references, all subsequent Modified version (not including errata content) or revisions do not apply to this standard, however, encourage the parties to study under this agreement is standard Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 6379 (all parts) of measurement methods and results Accuracy (trueness and precision) GB 9133 Classification of radioactive waste GB 14500 radioactive waste management Principle 3 5L acidified water samples with lead sulfate, barium, radium co-precipitation and dissolved with disodium edetate (EDTA disodium), filtered to Insoluble debris re-use sulfate precipitate was dissolved with diethyl be sub-pentaacetic acid (DTPA, C14H23N3O10) after 228Ac grow again As sulfate precipitation, the precursor 226Ra and 228Ac separate solution of the ester (P204, C16H35O4P) and extracted with di (2-ethylhexyl), anti-nitrate Extraction, cerium oxalate precipitate source system, measuring 228Ac, and the standard comparison solution at low background β means, including the degree of 228Ac get, and then converted into 228Ra activity. Sulfate precipitate was dissolved with disodium edetate charged diffuser. It closed a few days later by emanation and measurement 226Ra Comparison of standard solutions obtained radium 226Ra activity, the final calculation of 226Ra and 228Ra radioactivity ratio.

4 Reagents

Unless otherwise stated in this section, both in the analysis using analytical grade and distilled water or equivalent purity water in line with national standards. 4.1 mannitol. 4.2 absolute ethanol (ρ0.78g/mL). 4.3 hydrochloride (ρ1.19g/mL). 4.4 hydrochloric acid solution (12). 4.5 nitric acid solution (114). 4.6 sulfuric acid solution (11). 4.7 Sodium hydroxide solution (100g/L). 100g of sodium hydroxide dissolved in water, diluted to 1000mL. 4.8 ammonia solution (12).

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 13072-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 13072-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 13072-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 13072-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 13072-2010?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 13072-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information