HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (8 Dec 2024)

GB/T 1270-1996 English PDF (GB/T 1270-2023 Newer Version)

GB/T 1270-1996 (GB/T1270-1996, GBT 1270-1996, GBT1270-1996)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 1270-2023English189 Add to Cart 3 days [Need to translate] Chemical reagent - Cobalt(Ⅱ) chloride hexahydrate Valid GB/T 1270-2023
GB/T 1270-1996English160 Add to Cart 0--9 seconds. Auto-delivery Chemical reagent. Cobalt (Ⅲ) chloride hexahydrate Obsolete GB/T 1270-1996
GB 1270-1985English199 Add to Cart 2 days [Need to translate] Chemical reagent--Cobalt chloride Obsolete GB 1270-1985
Preview PDF: GB/T 1270-1996    Standards related to: GB/T 1270-1996

BASIC DATA
Standard ID GB/T 1270-1996 (GB/T1270-1996)
Description (Translated English) Chemical reagent. Cobalt (��) chloride hexahydrate
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G62
Classification of International Standard 71.040.30
Word Count Estimation 6,640
Date of Issue 1996/8/22
Date of Implementation 1997/2/1
Older Standard (superseded by this standard) GB 1270-1985
Quoted Standard GB/T 601-1988; GB/T 602-1988; GB/T 603-1988; GB/T 619-1988; GB 6682-1992; GB/T 9723-1988; GB/T 9738-1988; GB 15346-1994,
Adopted Standard ISO 6353-3-1987, MOD
Drafting Organization Shanghai Reagent Factory
Administrative Organization Beijing Chemical Reagent Plant
Proposing organization Ministry of Chemical Industry of the People Republic of China
Issuing agency(ies) State Bureau of Technical Supervision
Summary This standard specifies the technical requirements for chemicals cobalt chloride hexahydrate, test methods, inspection rules, and packaging and logo.


GB/T 1270-1996 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.040.30 G 62 Replaces GB 1270-85 Chemical reagent - Cobalt (II) chloride hexahydrate APPROVED ON: AUGUST 22, 1996 IMPLEMENTED ON: FEBRUARY 01, 1997 Issued by: The State Bureau of Quality and Technical Supervision Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Traits ... 6  4 Specifications ... 6  5 Tests... 6  6 Inspection rules ... 10  7 Packaging and marks ... 10  Foreword This standard gives two levels: analytically-pure and chemically-pure, of which analytically-pure equivalently uses R 55 “cobalt chloride hexahydrate” in ISO 6353-3:1987 “Reagents for chemical analysis - Part 3: Specifications - Second series”. The differences are as follows: 1 Standard preparation According to China's national conditions, this Standard adds three chapters: traits, inspection rules, packaging and marks. 2 Specifications 2.1 Items According to China's national conditions, this Standard adds nitrate, manganese, iron, compared with ISO 6353-3:1987. 2.2 Indicators Analytically-pure nickel and ammonium sulfide without precipitation are stricter than ISO 6353-3:1987. Other items are the same as ISO 6353-3:1987. 3 Tests The determination methods for content, sulfate, ammonium sulfide non- precipitate in this Standard are basically the same as ISO 6353-3:1987. But there are differences in determination conditions. Experiments show that there is no significant difference in the results. Other items refer to the corresponding standards in a set of general test method standards for chemical reagents that China has developed. This set of standards is basically formulated using ISO 6353-1:1982 "Reagents for chemical analysis - Part 1: General test methods". This Standard revised and replaced GB 1270-85 “Chemical reagent - Cobalt chloride”. Compared with GB 1270-85, it deleted the level of guaranteed. In order to adopt the international standard, corresponding changes have been made in specifications and test methods in this Standard. This standard will replace GB 1270-85 from the effective date. This Standard was drafted in accordance with the rules given in GB/T 1.1-2009. This Standard was proposed by Ministry of Chemical Industry of the People's Republic of China. Chemical reagent - Cobalt (II) chloride hexahydrate Molecular formula: CoCl2•6H2O Relative molecular mass: 237.93 1 Scope This Standard specifies technical requirements, test methods, inspection rules and packaging as well as marks for chemical reagent - cobalt (II) chloride hexahydrate. 2 Normative references The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standard. At the time of publication, the editions indicated are valid. All standards are subject to revision. The parties who are using this Standard shall explore the possibility of using the latest version of the following standards. GB/T 601-88, Chemical reagent - Preparations of standard volumetric solutions GB/T 602-88, Chemical reagent - Preparations of stock standard solutions GB/T 603-88, Chemical reagent - Preparations of reagent solutions for use in test methods GB/T 619-88, Chemical reagent - Regulations for sampling and acceptance GB 6682-92, Water for analytical laboratory use - Specification and test methods (eqv ISO 3696:1987) GB/T 9723-88, Chemical reagent - General rules for flame atomic absorption spectrometry GB/T 9738-88, Chemical reagent - General method for the determination of water insoluble matter (eqv ISO 6353-1:1982) GB 15346-94, Chemical Reagent - Packaging and Marking Where, X - Mass percentage of cobalt chloride hexahydrate, %; V - Volume of standard titration solution of disodium ethylenediaminetetraacetic acid, mL; c - Concentration of ethylenediaminetetraacetic acid disodium standard titration solution, mol/L; 237.9 - Molar mass of cobalt chloride hexahydrate [M(CoCl2•6H2O)], g/mol; m - Sample mass, g. 5.2 Water insoluble matter Weigh 10g of sample. Dissolve in 100mLof boiling water. Cool to room temperature. Determine according to GB/T 9738. 5.3 Sulfate 5.3.1 Preparation of sulfate-free cobalt chloride hexahydrate solution Weigh 1g of sample. Dissolve in 20mLof water. Add 10mL of 95% ethanol, 2mL of hydrochloric acid solution (10%). Under constant shaking, add 5mL of barium chloride solution in drops (250g/L). Dilute to 50mL. Shake well. Place for 12h~18h. Filter it. 5.3.2 Determination method Weigh 1g of sample. Dissolve in water. Dilute to 50mL.Take 10mL. Add 5mLof 95% ethanol, 1mL of hydrochloric acid solution (10%). Under constant shaking, add 3mL of barium chloride solution (250g/L). Dilute to 25mL. Shake well. Place for 10min. The turbidity of the solution shall not be greater than the standard comparison solution. Preparation of standard comparison solution: take 10mL of sulfate-free cobalt chloride hexahydrate solution and sulfate standard solution that contains the following quantity: Analytically-pure Chemically-pure Light source: iron hollow cathode lamp; Wavelength: 248.3nm; Flame: acetylene-air. 5.6.2 Determination method Weigh 25g of sample. Dissolve in water. Dilute to 100mL. Take 20mL, four portions in total. Determine according to the provisions of 6.2.2 in GB/T 9723- 88. 5.7 Nickel Determine according to the provisions of GB/T 9723, of which: 5.7.1 Instrument conditions Light source: nickel hollow cathode lamp; Wavelength: 232.0nm; Flame: acetylene-air. 5.7.2 Determination method Weigh 5g of sample. Dissolve in water. Dilute to 100mL. Take 10mL, four portions in total. Determine according to the provisions of 6.2.2 in GB/T 9723- 88. 5.8 Copper Determine according to the provisions of GB/T 9723-88. 5.8.1 Instrument conditions Light source: copper hollow cathode lamp; Wavelength: 324.8nm; Flame: acetylene-air. 5.8.2 Determination method Weigh 25g of sample (take 5g for chemically-pure). Dissolve in water. Dilute to 100mL. Take 20mL, four portions in total. Determine according to the provisions of 6.2.2 in GB/T 9723-88. 5.9 Zinc ......