US$229.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 11030-2008: Characteristics of rod ceramic insulators for a.c. contact system of electrified railways Status: Valid GB/T 11030: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 11030-2008 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Characteristics of rod ceramic insulators for a.c. contact system of electrified railways
| Valid |
GB/T 11030-2008
|
| GB 11030-2000 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Loss of bulk petroleum liquid products
| Obsolete |
GB 11030-2000
|
| GB 11030-1989 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Anti-pollution type rod porielain insulators for the contact networks of railway a. c traction system
| Obsolete |
GB 11030-1989
|
PDF similar to GB/T 11030-2008
Basic data | Standard ID | GB/T 11030-2008 (GB/T11030-2008) | | Description (Translated English) | Characteristics of rod ceramic insulators for a.c. contact system of electrified railways | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K48 | | Classification of International Standard | 29.080.10 | | Word Count Estimation | 10,155 | | Date of Issue | 2008-06-30 | | Date of Implementation | 2009-04-01 | | Older Standard (superseded by this standard) | GB 11030-2000 | | Quoted Standard | GB/T 1001.1-2003 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to the nominal voltage of 25kV, frequency single-phase AC electrified railway catenary Rod porcelain insulator (hereinafter referred to as insulators). This standard applies to light- polluted area, heavy pollution areas and high altitudes catenary wrist and arm support insulators. This standard specifies the electrical insulator properties, mechanical properties and dimensional characteristics (see Table 1). This standard also specifies the insulator models and methods of marking. Note 1: GB/T 1001. 1-2003 general definition given in the test method. Note 2: GB/T 1001. 1-2003 The term " electric traction lines " with this standard, the term " electric railway " has the same meaning. |
GB/T 11030-2008: Characteristics of rod ceramic insulators for a.c. contact system of electrified railways ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Characteristics of rod ceramic insulators for accontact system of electrified railways
ICS 29.080.10
K48
National Standards of People's Republic of China
Replacing GB 11030-2000
Exchange of electrified railway catenary with
Rod porcelain insulators Characteristics
Posted 2008-06-30
2009-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB 11030-2000 "ac traction lines with porcelain insulators Rod" in size and features section.
This standard compared with GB 11030-2000 in the size and nature of the content main changes are as follows.
--- Increasing the mechanical failing load 12kN and 16kN level two varieties, delete the tunnel with hanging and positioning of two formula
Species;
--- Creepage distances former 1000mm, 1200mm and 1500mm three kinds of change 1200mm, 1400mm and 1600mm
Three kinds;
--- Remove the original standard in Appendix A "method of measuring the quality and appearance of the glaze layer semiconductor resistance" content added "Insulators cantilever
Jack location of the pin "content;
--- Remove the original standard Appendix B "transitional insulator main dimensions and characteristics of the" content, increase the "old model, said insulator party
Law "content.
This standard should be GB/T 1001.1-2003 "nominal high voltage overhead line insulators above 1000V - Part 1. System AC
Ceramic or glass insulator element definitions, test methods and acceptance criteria "used in conjunction.
Appendix A of this standard and Appendix B is an informative annex.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee Insulators (SAC/TC80) centralized.
This standard was drafted. Xi'an Institute of Electric Porcelain, Third Railway Survey and Design Institute, Suzhou Cichang like.
The main drafters of this standard. Dingjing Ling, Guo Wei Gong, Lu Chau.
This standard replaces the standards previously issued as follows.
--- GB 11030-1989, GB 11030-2000.
Exchange of electrified railway catenary with
Rod porcelain insulators Characteristics
1 Scope
This standard applies to nominal voltage of 25kV, AC single-phase power frequency electric railway catenary Rod porcelain insulators (hereinafter referred to as absolute
Edge sub).
This standard applies to light-polluted area, heavy polluted area and high altitudes catenary cantilever supporting insulators.
This standard specifies the characteristics of electrical insulators, mechanical properties and dimensional characteristics (see Table 1).
This standard also specifies the insulator model and methods of marking.
Note 1. A general definition, test method GB/T 1001.1-2003 in.
Note 2. GB/T 1001.1-2003, the term "electric traction lines" with this standard, the term "railway electrification" has the same meaning.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1001.1-2003 nominal voltage above 1000V Insulators for overhead lines - Part 1. Ceramic or glass AC system
Glass insulator element definitions, test methods and acceptance criteria (IEC 60383-1.1993, MOD)
3 models and signs
How to order.
Exchange of electrified railway catenary Rod porcelain insulators
Minimum bending failing load (digital)/kN
D represents a single insulated, S indicates double insulation
Lightning impulse withstand voltage (digital)/kV
๎
๎
๎
The minimum nominal creepage distance (Digital)/mm
For example, Q12S-310/1600, he said.
Q --- AC electrified railway catenary Rod porcelain insulators;
12 --- minimum bending failure load 12kN;
S --- double insulated;
310 --- lightning impulse withstand voltage 310kV;
1600 --- The minimum nominal creepage distance of 1600mm.
4 electrical, mechanical and dimensional characteristics
This standard specifies the following characteristics.
--- Minimum mechanical failing load;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 11030-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 11030-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 11030-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 11030-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 11030-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 11030-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|