Path:
Home >
GB >
Page68 > GB 7000.219-2008
Home >
Standard_List >
GB >
Page68 > GB 7000.219-2008
US$439.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 7000.219-2008: Luminaires -- Part 2-19: Particular requirements -- Air-handling luminaires
Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 7000.219-2008 | English | 439 |
Add to Cart
|
3 days [Need to translate]
|
Luminaires -- Part 2-19: Particular requirements -- Air-handling luminaires
| Obsolete |
GB 7000.219-2008
|
PDF similar to GB 7000.219-2008
Basic data
| Standard ID | GB 7000.219-2008 (GB7000.219-2008) |
| Description (Translated English) | Luminaires -- Part 2-19: Particular requirements -- Air-handling luminaires |
| Sector / Industry | National Standard |
| Classification of Chinese Standard | K72 |
| Classification of International Standard | 29.140.40; 93.080.30 |
| Word Count Estimation | 11,141 |
| Date of Issue | 2008-12-31 |
| Date of Implementation | 2010-02-01 |
| Older Standard (superseded by this standard) | GB 7000.14-2000 |
| Adopted Standard | IEC 60598-2-19-1981 + A1-1987 + A2-1997, IDT |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 23 of 2008 (No. 136 overall) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This Chinese standard relates to use of ventilation ducts for ventilation space (forced ventilation) Ventilation luminaires safety requirements. With tubular fluorescent lamps as the light source, the power supply voltage not exceeding 1000V. This standard should be used in conjunction with GB 7000. 1. It should be noted that this standard only provides a ventilated luminaires safety requirements, there is no specified performance requirements. Note 1: this standard of the"airy"and"airy"refers to the forced ventilation. Note 2: this standard does not use tungsten and except for tubular fluorescent lamps discharge lamps other than the request. |
GB 7000.219-2008: Luminaires -- Part 2-19: Particular requirements -- Air-handling luminaires
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Luminaires.Part 2-19. Particular requirements.Air-handling laminalrea s
ICS 29.140.40; 93.080.30
K72
National Standards of People's Republic of China
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
Replacing GB 7000.14-2000
Luminaires - Part 2-19. Particular requirements
Ventilation fixtures
(IEC 60598-2-19. 1981 + A1. 1987 + A2.1997, IDT)
Published 2008-12-31
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Preface Ⅰ
Introduction IEC Ⅲ
1 Scope 1
2 1 General test requirements
3 Definitions 1
4 lamps Category 1
Flag 1 5
6 Structure 2
7 creepage distances and clearances 2
8 Ground 2 provisions
Terminal 2 9
10 external and internal lines 2
11 Protection against electric shock 3
Thermal test and durability test 12 3
13 dust, water and solid objects 4
14 Insulation resistance and electric strength 4
15 heat, fire, and the resistance to tracking 4
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
Foreword
All technical contents of this section is mandatory.
This section GB 7000 "lamps" Part 2-19, GB 7000 series of standards existing section 22, the publication date of this section, has
Published GB 7000 series of standards are as follows.
GB 7000.1-2007 lamps - Part 1. General Requirements and Test
GB 7000.2-2008 lamps - Part 2-22. Particular requirements for emergency lighting
GB 7000.4-2007 lamps Part 2-10. Particular requirements for children luminaries
GB 7000.5-2005 road and street lighting safety requirements
GB 7000.6-2008 lamps - Part 2-6. Particular requirements with a built-in transformer or converter tungsten lamp
GB 7000.7-2005 safety requirements Floodlights
GB 7000.9-2008 lamps Part 2-20. Particular requirements for light string
GB 7000.17-2003 safety requirements limit the surface temperature of the lamp
GB 7000.18-2003 filament lamps extra low voltage lighting system security requirements
GB 7000.19-2005 photo and film (non-professional use) Safety requirements for lighting
GB 7000.201-2008 lamps - Part 2-1. Particular requirements for fixed general purpose luminaires
GB 7000.202-2008 Luminaires - Part 2-2. Particular requirements Recessed Lighting
GB 7000.204-2008 lamps - Part 2-4. Particular requirements for portable general purpose luminaires
GB 7000.207-2009 lamps - Part 2-7. Particular requirements for garden use luminaries
7000.208-2008 lamps - Part 2-8 GB . Particular requirements handlamps
GB 7000.211-2008 lamps Part 2-11. Particular requirements for the aquarium lamp
GB 7000.212-2008 lamps - Part 2-12. Particular requirements for the power outlet mounted nightlight
GB 7000.213-2008 Luminaires - Part 2-13. Particular requirements for ground recessed light fixtures
GB 7000.217-2008 lamps Part 2-17. Particular requirements for stage lighting, television, film and photographic studios (indoor and outdoor)
Lighting
GB 7000.218-2008 Luminaires - Part 2-18. Particular requirements for swimming pools and similar lighting
GB 7000.219-2008 lamps - Part 2-19. Particular requirements for ventilated luminaires
GB 7000.225-2009 Luminaires - Part 2-25. Particular requirements. the building of hospitals and rehabilitation clinics lamp
This section is equivalent to using the International Electrotechnical Commission IEC 60598-2-19. 1981 "Luminaires - Part 2. Particular requirements through Chapter 19
Wind lamps, "1987 Amendment No. 1 and No. 2, 1997 Amendment.
This partial replacement GB 7000.14-2000.
The main difference in this section GB 7000.14-2000 comprises.
--- reference standard GB 7000.1-1996 instead GB 7000.1;
--- "present standard" to "this section";
--- standard name to "lamps - Part 2-19. Particular requirements for ventilated luminaires"; Standard changed from GB 7000.14
GB 7000.219;
--- "dielectric strength" to "electric strength";
--- "factory" to "manufacturer."
Appendix A of this section is informative appendix.
This section was proposed by China Light Industry Federation.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
This part of the jurisdiction of the National Standardization Technical Committee of electrical lighting fixtures Branch.
This section was drafted. National Lighting Fitting Quality Supervision and Inspection Center, the National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Shanghai era
Lighting Appliance Testing Co., Philips Lighting (Shanghai) Co., Ltd., Shanghai Institute of lighting fixtures.
This part drafter. Chen Chao in Shi Xiaohong, Sang high element, as in Li, Liu Yue accounting.
This part of the first edition published in July 2001, this edition is the first revision.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
IEC Foreword
1) IEC formal decisions or agreements on technical issues, was attended by representatives of the International Committee of the technical issues of interest to the Commission
Members will be developed to express the international consensus on as closely as possible.
2) These resolutions and agreements in the form of standards, technical reports or guides and publishing, to recommend ways for use by States, in this sense
It has been accepted by the National Committees.
3) In order to promote international unification, IEC National Committees undertake to maximize the use of IEC international standards as national standards or to
Standard area. IEC standards and any difference between the corresponding national standard should be pointed out as clearly as possible in the latter.
IEC 1987 No. 1 by the Rev. 60598-2-19 IEC Technical Committee 34, light bulbs and related products Technical Committee
34D lamps at the Technical Committee to develop.
1987 No. 1 Rev. following documents.
June vote Reporting Act
34D (CO) 111 34D (CO) 128
For details on this Rev. vote, the vote on the report can be seen in the table.
IEC 1997 No. 2 by the Rev. 60598-2-19 IEC Technical Committee 34, light bulbs and related products Technical Committee
34D lamps at the Technical Committee to develop.
1997 Rev. 2 is based on the following documents.
FDIS Report on voting
34D/471/FDIS 34/481/RVD
For details on this Rev. vote, the vote on the report can be seen in the table.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
Luminaires - Part 2-19. Particular requirements
Ventilation fixtures
Range 1
GB 7000 specifies this section (forced ventilation) Safety requirements using a ventilated luminaires or ventilation duct for ventilation space.
In tubular fluorescent lamps as the light source, the power source voltage does not exceed 1000V. This section should be used with GB 7000.1.
It should be noted that this section only specifies requirements for ventilation luminaires security, no requirement performance.
Note 1. in this section, "air" and "vent" means forced ventilation.
Note 2. This section does not request the use of other than tungsten and tubular fluorescent lamps of the gas discharge lamp.
2 General test requirements
7000.1 provisions of Chapter 0 Application GB . GB 7000.1 test specified in the test according to the test specified in this order.
Definition 3
7000.1 defined in Chapter 1 GB and the following definitions apply.
3.1
A lamp is used in conjunction with specially designed air conditioning system.
Note. The air may pass a light source or a separate plenum chamber.
3.2
Operating state of the lamp, neither ventilation nor forced air, but allows air convection.
Lighting Category 4
Application of a predetermined 7000.1 Chapter 2 GB , but ventilated luminaires should be classified as Class Ⅰ, Ⅱ Ⅲ class and classes.
5 Mark
Application of GB 7000.1 Chapter 3 5.1 to 5.4 with the following provisions.
5.1 no markings of the built-ventilated luminaires should contain on the attached label or on the manufacturer's instructions provided with the lamp indicates
The following warning content, i.e. a groove in the outer surface of the inner member can not be mounted in any fixture within 25mm from the general surface of combustible materials
local.
5.2 are marked ventilated luminaires, lamps should indicate the type of structure, this information should be marked on the fixture, or the manufacturer's instructions
Is given in the book, the content should be two or one of the following.
"Ventilation duct for connection."
"Working in a ventilated space."
For ventilation apertures adapted lamps equipped with ventilation ducts while increasing attachment, the attachment shall be marked on the lamp.
"Ventilation duct for connection."
5.3 GB 7000.1 3.3.6 mentioned in the "special conditions" shall include the following.
a) not marked with a minimum distance between the marker lamps ordinary combustible member, and the lamp body of the building structure allows;
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
b) suitable type, for example, "used in the plenum."
6 structure
7000.1 The following provisions of Chapter 4 of the application of 6.1 to 6.3 GB .
6.1 pairs embedded member, and the spring compression impact energy test specified in GB 7000.1 4.13 should provide in accordance with the following Table 1.
Table 1 and the impact energy is spring compression
Impact energy test was member/Nm compression/mm
Providing protection against electric shock member (excluding the ceramic member) 17 0.35
Ceramic member and all other components of the lamp 13 0.20
6.2 If avoid fire hazard, to ensure that the minimum distance between the lamp and certain architectural structural member, with the spacer on the luminaire or class
Like device, the method of fixing these devices should enable these devices can not be removed unless cause permanent damage or that it can not be installed properly.
This provision does not apply because only affect the security structure needs to be provided spacers.
Note. fire hazard location. In some countries, the ventilation system as a fire hazard location, and in these cases, we recommend the following apply.
a) a housing to be ventilated luminaires metal or other non-combustible material, and carrying out tests of this Chapter 12, should not exceed the temperature of the lamp body
Over 100 ℃. The lamp may be vented, but the total area of the holes should not exceed 10% of the body surface area of the lamp.
b) on the horizontal width of the hole facing should not exceed 6mm, width of the other holes can not exceed 10mm. Further, the inner face on the other planes
Hole, the width in the horizontal plane of the projector must not exceed 6mm.
Lamps with a width of the ventilation duct and the short tube connection hole is not limited.
c) ventilated lamp ballast, connecting means element, and the like through-wiring to use a non-combustible material of the protective housing, in order to prevent dust erosion.
This may be part of the housing element. When the rated current is not exceeded. 2A, the seat does not apply to the socket, and the connection start means and
Short connecting wires.
6.3 pairs of conventional surface mounted directly on the combustible material, i.e. with the mark of the lamps, GB 7000.1 4.16.1 predetermined not suitable for use in
For forced ventilation hole. Ventilation strip of luminaires cannula (connected to air device), the test should be done of the sleeve surface as the surface of the lamp.
7 creepage and clearance distances
7000.1 provisions of Chapter 11 Application GB .
8 grounding provisions
The provisions of Chapter 7 7000.1 Application GB .
Terminal 9
7000.1 application of the provisions of Chapters 14 and 15 GB .
External and internal wiring 10
Application of GB 7000.1 Chapter 5 and 10.1 the following provisions.
10.1 When the flexible cable or cord connected to the supply as the method by the manufacturer when, should meet GB 5023.1 ~ 5023.7 "rated voltage
450/750 and below PVC insulated cables "and GB 5013.1 ~ 5013.7" rated voltage and below rubber insulated cables 450/750 "
Under the mechanical and electrical performance requirements, and can withstand a maximum temperature under normal conditions of use may be subjected without damage.
Qualification testing by the test section in Chapter 12.
Note. the flexible cables and cords embedded ventilated luminaire should be suitable for the following cases.
a) flexible cables and cords is not accessible and can not touch flexible cables and cords inside the groove;
b) lamps should readily into the recess;
c) adjustable ventilated luminaires embedded easy to adjust.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
11 Protection against electric shock
7000.1 provisions of Chapter 8 of the application GB .
Thermal test and durability test 12
Application GB Chapter 12 requires 7000.1 12.1 - 12.3 below.
12.1 Thermal test (normal operation)
12.1.1 tests were conducted under static operating conditions.
Detailed description of the general structure of the test groove, e.g., the thickness of the wall should comply with the following provisions and Appendix D of GB 7000.1.
When lamps with ventilation duct connected to the ventilation sleeve experiment, the cannula should be connected to the side or top of the chamber.
When the ventilation air flow aperture lamps were tested, the respective side surface 4.5mm thick hardboard cap and the chamber may be
By the sealed, provided with a central distance 25mm, the plurality of apertures of 4.5mm aperture cover on the entire plane.
When the test, marked with the symbol embedded ventilated luminaire is mounted in the recess, a distance from the top surface of the test recesses may be 0mm
(See FIG. 1) or 25mm (see FIG. 2), but for the lighting installation when not so marked with the symbol of the flat top surface of the solid from the test groove
25mm top surface (see FIG. 1) or 60mm (see Figure 2).
Distance "X"/mm
Marked lamps 0
No marker lamps 25
FIG. 1 is connected with the ventilation duct with the ventilation sleeve lamps mounted in the test method of the groove
Distance "X"/mm
Marked lamps 25
No marker lamps 60
FIG 2 is provided with a ventilated luminaires installed in the ventilation method of the pore space of the recess in the test
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
12.1.2 When the test, except that the temperature tubular fluorescent tube glass surface can not exceed 150 ℃ outside, in the main air channel facing the range
The surface temperature should not exceed 100 ℃.
Exchanging gas leaving the temperature of the lamp should not exceed 100 ℃.
Test temperature in all parts of the groove can not exceed 90 ℃.
12.2 by the lamp or lamps will contact terminals connected to the supply temperature should reach unsafe. 12.2.1 Compliance is checked by the test
And the provisions of 12.2.2 to test.
12.2.1 lamp connected to a power cable on the sign should predetermined lamp or lamps provide a flexible cable, which is not marked, said use
Cable specified on the next book. Otherwise, use PVC cable on the provisions of GB 5023.
Find the hottest part (the outer surface of the inner line or along the lamps) along the normal working position cable may contact the cable portion
Light contact member, the contact point of measuring the temperature of this insulating layer by the method according to Appendix K GB 7000.1.
12.2.2 cable working temperature must not exceed the limits in Table 2.
12.3 Thermal test (abnormal operation)
12.3.1 tested under static operating conditions
Lighting installation according to the provisions of 12.1.1.
12.3.2 During the test, in addition to the temperature of the surface of tubular fluorescent tubes can not exceed 150 ℃ outside, within a range facing the air passage
Surface temperature should not exceed 130 ℃.
Test temperature in all parts of the groove can not exceed 130 ℃.
IP higher than IP20 lamps accordance with the provisions of Chapter 13 of the present, after the test specified in 9.2 GB 7000.1, a pilot 9.3
GB 7000.1 test conducted 12.4,12.5 and 12.6 in the previous test.
Table 2 cable operating temperature
Cable working temperature limit specified
Cable (including the sheath) providing a predetermined maximum temperature GB 7000.1 12.2 Table lamp with
Lighting does not provide wire
a) the temperature of the cable marker lamps
b) the temperature of the lamp is not marked cable
Labeled temperature
The provisions of GB 7000.1 12.2 Table Normal P. V. C is the maximum temperature, not
Under the influence of mechanical stress
13 dust, solid objects and water
Application of GB 7000.1 Chapter 9.
Lamps of higher than IP20 IP, the test sequence specified in GB 7000.1 Chapter 9 of this part should be required Chapter 12.
14 Insulation resistance and electric strength
Application of GB 7000.1 Chapter 10.
15 heat, fire resistance to tracking and
Application of GB 7000.1 Chapter 13.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
Appendix A
(Informative)
Lower. "For ventilation lamps," normal "to set the type of air-conditioning and lighting systems used simultaneously, requiring a predetermined measurement
Specified in this state is static working state, i.e., the lamp does not forced ventilation exhaust, but allows normal flow of air, on the luminaire
When the air-conditioning system as a lighting installation member, the ambient temperature near the lamp determined by the type and properties of the system, but only by these
User evaluation.
On the assessment, the temperature should be measured at the midpoint of the recess lighting installation space, with a static model or simulate lighting fixture in its place
Limiting effect on the free flow of air generated.
For the worst case may occur when the analog forced ventilation, when feeding cold or at room temperature for ventilation, air circulation system should be shut down
When the measured temperature, while the air fed to higher than room temperature, can open the air circulation system to measure temperature.
GB 7000.219-2008/IEC 60598-2-19. 1981 + A1. 1987 + A2.1997
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB 7000.219-2008_English be delivered?
Answer: Upon your order, we will start to translate GB 7000.219-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB 7000.219-2008_English with my colleagues?
Answer: Yes. The purchased PDF of GB 7000.219-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to
[email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.