|
US$929.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 3389-2008: Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter Status: Valid GB/T 3389: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 3389-2008 | English | 929 |
Add to Cart
|
7 days [Need to translate]
|
Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter
| Valid |
GB/T 3389-2008
|
| GB/T 3389.1-1996 | English | 909 |
Add to Cart
|
5 days [Need to translate]
|
Vocabulary for ferroelectric and piezoelectric ceramics
| |
GB/T 3389.1-1996
|
| GB 3389.1-1982 | English | 919 |
Add to Cart
|
6 days [Need to translate]
|
Test methods for the properties of piezoelectric ceramics commonly used terms
| Obsolete |
GB 3389.1-1982
|
PDF similar to GB/T 3389-2008
Basic data | Standard ID | GB/T 3389-2008 (GB/T3389-2008) | | Description (Translated English) | Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L90 | | Classification of International Standard | 31-030 | | Word Count Estimation | 42,419 | | Date of Issue | 2008-08-04 | | Date of Implementation | 2009-02-01 | | Older Standard (superseded by this standard) | GB/T 3389.2-1999; GB/T 3389.3-2001; GB/T 3389.4-1982; GB/T 3389.5-1995; GB/T 3389.6-1997; GB/T 3389.7-1986; GB/T 3389.8-1986 | | Quoted Standard | GB/T 2413; GB/T 2414.1; GB/T 3389.1; CB/T 1218-1993 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2008 (No. 125 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the piezoelectric ceramic material properties of the test conditions, test methods and test methods vibration mode. This standard applies to the Curie temperature piezoelectric ceramics, piezoelectric strain constant (static), high field dielectric properties, pyroelectric coefficient of parametric tests, the longitudinal length of piezoelectric ceramic materials telescopic cylinder, telescopic and wafer thickness rectangular slice thickness shear vibration mode parametric test. |
GB/T 3389-2008: Test methods for the properties of piezoelectric ceramics -- Test for the performance parameter ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for the properties of piezoelectric ceramics. Test for the performance parameter
ICS 31-030
L90
National Standards of People's Republic of China
Replacing GB/T 3389.2-1999, GB/T 3389.3-2001, GB/T 3389.4-1982, GB/T 3389.5-1995, GB/T 3389.6-1997,
GB/T 3389.7-1986, GB/T 3389.8-1986
Properties of piezoelectric ceramics test methods
Test performance parameters
Posted 2008-08-04
2009-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms, definitions and symbols 1
4 1 Test Conditions
4.1 Test atmospheric conditions 1
4.2 Test atmospheric conditions arbitration 1
5 Performance Test 1
5.1 Curie temperature 1
5.2 longitudinal piezoelectric strain constant (static) 2
5.3 High Field Dielectric Properties 4
5.4 pyroelectric coefficient 6
5.5 cylinder longitudinal length extension vibration mode 7
5.6 Thickness extension vibration mode 10
5.7 rectangular sheet thickness shear vibration mode 12
--- GB/T 3389.4-1982;
--- GB/T 3389.5-1982, GB/T 3389.5-1995;
--- GB/T 3389.6-1982, GB/T 3389.6-1997;
--- GB/T 3389.7-1986;
--- GB/T 3389.8-1986.
Properties of piezoelectric ceramics test methods
Test performance parameters
1 Scope
This standard specifies the test methods of piezoelectric ceramics test conditions, test methods and vibration mode.
This standard applies to the Curie temperature of the piezoelectric ceramic material, the Senate piezoelectric strain constant (static), the strong field dielectric properties, pyroelectric coefficient
The number of tests, the piezoelectric ceramic material cylinder longitudinal length of the stretch, stretch and rectangular wafer thickness thickness shear vibration mode parameter testing.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2413 piezoelectric ceramic material bulk density measurement method
GB/T 2414.1 Test methods for properties of piezoelectric ceramics discs radially stretching vibration mode
GB/T 3389.1 ferroelectric ceramics vocabulary
CB/T 1218-1993 hydroacoustic common piezoelectric ceramic element
3 Terms, definitions and symbols
GB/T terms, definitions and symbols established 3389.1 apply to this standard.
4 Test Conditions
4.1 Test atmospheric conditions
Test atmospheric conditions are as follows.
a) Temperature. 15 ℃ ~ 35 ℃;
b) Relative humidity. 25% to 75%;
c) Atmospheric pressure. 86kPa ~ 106kPa.
4.2 Arbitration test atmospheric conditions
Arbitration test atmospheric conditions are as follows.
a) temperature. 25 ℃ ± 2 ℃;
b) Relative humidity. 45% to 55%;
c) Atmospheric pressure. 86kPa ~ 106kPa.
5 Performance Testing
5.1 Curie temperature
5.1.1 Test principle
When the temperature is higher than the Curie temperature (TC), the piezoelectric ceramics in the paraelectric phase, spontaneous polarization and piezoelectric properties also vanish. The Curie temperature
Degrees, many of the physical properties of piezoelectric ceramic material, such as permittivity, heat capacity, coefficient of linear expansion are mutated, so long as this measurement
Point mutations can determine the temperature corresponding to the Curie temperature of the piezoelectric ceramic material. This standard uses a test sample to determine the permittivity of the piezoelectric point mutation
Curie temperature of the ceramic material, and recommended impedance analyzer to measure the mutation point.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 3389-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 3389-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 3389-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 3389-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 3389-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 3389-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|