HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (17 Jan 2026)
Path: Home > GB > Page116 > GB 30252-2013                   Home > Standard_List > GB > Page116 > GB 30252-2013

GB 30252-2013 English PDF

US$359.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 30252-2013: The norm of energy consumption per unit product of ultra-white patterned glass
Status: Obsolete
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 30252-2013English359 Add to Cart 3 days [Need to translate] The norm of energy consumption per unit product of ultra-white patterned glass Obsolete GB 30252-2013

PDF similar to GB 30252-2013


Standard similar to GB 30252-2013

GB 30253   GB 30254   GB 30255   GB 30251   GB 30253   GB 30254   

Basic data

Standard ID GB 30252-2013 (GB30252-2013)
Description (Translated English) The norm of energy consumption per unit product of ultra-white patterned glass
Sector / Industry National Standard
Classification of Chinese Standard F01
Classification of International Standard 27.010
Word Count Estimation 9,965
Quoted Standard GB/T 2589; GB/T 12497; GB/T 12723; GB/T 13462; GB/T 13469; GB/T 13470; GB 17167; GB/T 17954; GB/T 17981; GB/T 18292; GB 18613; GB/T 19065; GB 19153; GB 19761; GB 19762; GB 20052; JC/T 2001
Regulation (derived from) National Standards Bulletin No. 26 of 2013
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies: PV rolled glass unit product energy consumption (energy consumption hereinafter referred to as "energy") limits the technical requirements, the scope of statistics calculations, and energy management measures. This standard applie

GB 30252-2013: The norm of energy consumption per unit product of ultra-white patterned glass

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The norm of energy consumption per unit product of ultra-white patterned glass ICS 27.010 F01 National Standards of People's Republic of China Rolled glass photovoltaic energy consumption per unit product patternedglass Issued on. 2013-12-18 2014-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

4.1 and 4.2 of this standard are mandatory, the rest are recommended. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the National Development and Reform Commission Resource Conservation and Environmental Protection, the Ministry of Industry and Information Technology Energy Saving and Comprehensive Utilization Department proposed. This standard by the National Standardization Technical Committee Foundation and Energy Management (SAC/TC20) and China Building Materials Federation focal point. This standard was drafted. National Glass Quality Supervision and Inspection Center, Lutheran photovoltaic industry (Anhui) Holdings Limited, photovoltaic glass Follett Glass Group Co., Ltd., the national security glass and quartz glass Quality Supervision and Inspection Center. The main drafters of this standard. HUANG Jian-bin, Liu Fu, Huan-Zhang Liu, Li friendship, Wang speech, Liu Xiaorong, peak, Zhang Jingling, Xiang Wang, TAN Xiao arrows, Ping Subo. Rolled glass photovoltaic energy consumption per unit product

1 Scope

This standard specifies the photovoltaic rolled glass unit product energy consumption (energy consumption hereinafter referred to as "energy") technical requirements limit the statistical norm Wai calculation method, and energy management measures. This standard applies to solar energy control rolled glass production enterprise energy consumption calculation, assessment and new projects.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2589 General Principles of comprehensive energy consumption calculation GB/T 12497 three-phase asynchronous motor economy GB/T 12723 energy consumption per unit of product preparation General GB/T 13462 Power Transformer Economic Operation GB/T 13469 centrifugal, mixed flow pumps, axial flow and vortex pump systems Economic Operation GB/T 13470 Ventilator System Economic Operation GB 17167 energy use per unit of energy measuring instruments and General Manager GB/T 17954 Industrial Boiler economy GB/T 17981 economic operation of the air conditioning system GB/T 18292 Life Boilers running GB 18613 small and medium three-phase asynchronous motor energy efficiency limit value and energy efficiency rating GB/T 19065 Electric Boiler economic operation GB 19153 displacement air compressors energy efficiency limit value and energy efficiency rating GB 19761 fan energy efficiency limit value and energy efficiency rating GB 19762 water pump energy efficiency of limited value and energy conservation evaluation values GB 20052-phase distribution transformer energy efficiency limit value and energy efficiency rating JC/T 2001 solar glass

3 Terms and Definitions

GB/T 12723 and defined by the following terms and definitions apply to this document. 3.1 PV rolled glass ultra-whitepatternedglass For polycrystalline silicon solar cell module cover plate ultra-white rolled glass. 3.2 Comprehensive energy consumption of photovoltaic rolled glass products thecomprehensiveenergyconsumptionofultra-whitepatternedglass In the reference period for the production of photovoltaic glass rolling energy consumption, in accordance with the calculation methods and unit conversion, respectively, after sum. 3.3 PV comprehensive energy consumption per unit of product rolled glass thecomprehensiveenergyconsumptionperunitproductsof ultra-whitepatternedglass In the statistical period, energy consumption per ton of rolled photovoltaic glass, the sum of the prescribed calculation methods and unit respectively after the conversion. 4. Technical Requirements 4.1 PV rolled glass unit product energy consumption limits Existing photovoltaic rolled glass production enterprises unit energy consumption limit values shall conform to Table 1. Table 1 PV rolled glass unit product energy consumption limits classification Comprehensive energy consumption per unit of photovoltaic rolled glass kgce/t ≤300t/d ≤400 > 300t/d ≤370 Note. The table ≤300t/d, > 300t/d means a glass melting furnace with a designed daily fluid volume (not including oxy-fuel glass melting furnace). 4.2 PV rolled glass unit product energy consumption value access New photovoltaic rolled glass production enterprises access unit energy consumption values should be in accordance with Table 2. Table 2 PV rolled glass unit product energy consumption value access classification Comprehensive energy consumption per unit of photovoltaic rolled glass kgce/t ≤300t/d ≤300 > 300t/d ≤260 Note. The table ≤300t/d, > 300t/d means a glass melting furnace with a designed daily fluid volume (not including oxy-fuel glass melting furnace). 4.3 PV rolled glass unit product energy consumption advanced value PV rolled glass manufacturers of advanced energy consumption per unit of product value should be in accordance with Table 3. Table 3 PV rolled glass unit product energy consumption advanced value classification Comprehensive energy consumption per unit of photovoltaic rolled glass kgce/t ≤300t/d ≤300 > 300t/d ≤260 Note. The table ≤300t/d, > 300t/d means a glass melting furnace with a designed daily fluid volume (not including oxy-fuel glass melting furnace).

5 statistical coverage and calculation methods

5.1 statistical range 5.1.1 Comprehensive range of energy statistics Including production and auxiliary energy consumption, excluding energy used in daily life. Energy production, including raw materials, melting, forming, annealing, cut cut and finished Packaging, fuel consumption, power and energy working fluid. Auxiliary energy consumption, including energy machine repair, power consumption and other departments, as well as a living Factory production of transport services, lighting energy consumption. Does not include the repair from the cold to put the glass of water to begin production of the energy consumed during the PV rolled glass, does not include winter heating fuel security Pipe, transport losses and for life, such as infrastructure, canteens, dormitories and other energy production sector and memory consumption of the region and to the recycling All the amount of outside energy output. 5.1.2 PV rolled glass production Total business during the reference period in accordance with JC/T 2001 requirements for production of qualified products (in tonnes). Integrated photovoltaic energy 5.1.3 Multi-seat rolled glass melting furnace per unit of product Companies have more than a photovoltaic rolled glass melting furnace, should be calculated separately determined for each seat unit comprehensive energy consumption of the furnace, for the common parts Press prorate energy yield. 5.1.4 energy enterprise wide range of products In addition to the photovoltaic business when rolled glass also produce other products, a variety of energy should be measured separately, for indeed impossible to separate the public can be measured Consumption, such as plant and warehouse lighting or various types of integrated energy output by product prorate. 5.2 Calculation Method 5.2.1 Calculation of the comprehensive energy consumption of products Shall comply with GB/T 2589's. 5.2.2 LHV fuel energy converted into standard coal and different calculation Calorific value of the fuel should take the weighted average reference period measured or calculated based on the weighted average fuel analysis, according to a variety of energy off Operators of a coal conversion coefficients (specific parameters and coefficients see Appendix A). 5.2.3 Kiln age factor Corresponding to the different jobs of glass furnace kilns TSE coefficients in Table 4. Table 4 kiln age factor Kiln of division/age factor in kiln Before designing kiln age 1/3 1.00 After the design of the kiln age 1/3 to 2/3 1.05 Design kiln age after 1.12 2/3 Effect coefficient 5.2.4 fuels Effect coefficient fuel Table 5. Effect Coefficient Table 5 fuels Effect coefficient fuels Fuel Oil 1.00 Gas 1.08 Coke oven gas 1.13 Furnace gas (heat) 1.20 Petroleum coke 1.00 5.2.5 PV rolled glass comprehensive energy consumption is calculated Solar energy should be integrated rolled glass formula (1). Eb = ec ed (1) Where. Eb --- overall energy consumption, namely all kinds of energy used for statistical period rolled glass production of photovoltaic consumed converted into standard coal, tonnes (T); ec --- primary fuel consumption, that is, the amount of various fuels used for statistical term photovoltaic rolled glass production furnace converted into standard coal consumption, Tonnes (t); ed --- other energy consumption, namely electricity, auxiliary production and transport of the plant used for statistical term photovoltaic rolled glass production consumed Consumption of fuel or electricity converted into standard coal, tonnes (t). 5.2.6 PV comprehensive energy consumption per unit of product rolled glass formula PV comprehensive energy consumption per unit of product rolled glass shall formula (2). eb = 1000 (× ecc1 · c2 e) d pb (2) Where. Eb --- photovoltaic comprehensive energy consumption per unit of product rolled glass, in kilograms per tonne of coal equivalent (kgce/t); pb --- Statistics photovoltaic glass rolling period total production of qualified products, tonnes (t); c1 --- kiln age coefficients in Table 4; Effect coefficient c2 --- fuel, etc., see Table 5. 5.2.7 PV rolled glass unit energy consumption to calculate the median selection Converted into standard coal, in kilograms per tonne of coal equivalent (kgce/t), after taking one decimal place.

6 and energy management measures

6.1 basic management of energy-saving 6.1.1 PV rolled glass manufacturers should be regularly consumed per unit of product produced in the amount of fuel and electricity consumption assessment, the establishment of energy responsibility system. 6.1.2 PV rolled glass manufacturers should be required to establish energy consumption statistics system, the establishment of the energy consumption test data, energy calculation and assessment results Paper files, and files controlled management. 6.1.3 PV rolled glass production enterprises should be equipped with energy measuring instruments according to the requirements of GB 17167 and the establishment of energy measurement management system. 6.2 Calculation of energy-saving management 6.2.1 energy-consuming equipment 6.2.1.1 rolled glass manufacturers of photovoltaic energy to deal with the main thermal equipment --- furnace to optimize the design of the overall structure, large-scale Of strengthening kiln heat insulation, the choice of energy-efficient combustion and control system; and motor systems, pump systems, ventilation system, power transformer , Industrial boilers, living boilers, electric heating boilers, air conditioning systems and other energy-consuming equipment in line with General GB/T 12497, GB/T 13469, GB/T 13470, GB/T 13462, GB/T 17954, GB/T 18292, GB/T 17981 and GB/T 19065 and other energy-related products Economy standards and reached the state of the economy. 6.2.1.2 new and renovation and expansion of small and medium enterprises with a three-phase asynchronous motors, displacement air compressor, fan, water pump, Three-phase distribution transformers and other common energy-consuming equipment should reach GB 18613, GB 19153, GB 19761, GB 19762, GB 20052 and other relevant Energy-consuming equipment energy efficiency standards for energy efficiency rating. 6.2.2 production process 6.2.2.1 photovoltaic rolled glass manufacturers in the production process, should take effective measures to make the production system is normal, continuous and stable operation, Improve the rate of operation of the system. 6.2.2.2 photovoltaic rolled glass manufacturers in the production process, equipment maintenance schedule should be strengthened, to prevent equipment downtime occurs outside, Often starting or stopping the equipment case.

Appendix A

(Informative) Low calorific value fuel and coal energy conversion reference coefficients Low calorific value fuel and coal energy conversion reference coefficients in Table A.1. Table A.1 low calorific value fuel and coal energy conversion reference coefficients The average energy of standard coal of low calorific value of the discount factor Coal 20908kJ/kg (5000kcal/kg) 0.7143kgce/kg Coal washing 26344kJ/kg (6300kcal/kg) 0.9000kgce/kg Other coal washing Coal washing 8363kJ/kg (0000kcal/kg) 0.2857kgce/kg Slime 8363kJ/kg ~ 12545kJ/kg (2000kcal/kg ~ 3000kcal/kg) 0.2857kgce/kg ~ 0.4286kgce/kg Coke 28435kJ/kg (6800kcal/kg) 0.9714kgce/kg Petroleum coke powder 35125kJ/kg (8400kcal/kg) 1.1800kgce/kg Crude 41816kJ/kg (10000kcal/kg) 1.4286kgce/kg Fuel 41816kJ/kg (10000kcal/kg) 1.4286kgce/kg Gasoline 43070kJ/kg (10300kcal/kg) 1.4714kgce/kg Kerosene 43070kJ/kg (10300kcal/kg) 1.4714kgce/kg Diesel 42652kJ/kg (10200kcal/kg) 1.4571kgce/kg Coal tar 33453kJ/kg (8000kcal/kg) 1.1429kgce/kg LPG 50179kJ/kg (12000kcal/kg) 1.7143kgce/kg Refinery dry gas 46055kJ/kg (11000kcal/kg) 1.5714kgce/kg Gas 38931kJ/m3 (9310kcal/m3) 1.3300kgce/m3 Coke oven gas 16726kJ/m3 ~ 17981kJ/m3 (4000kcal/m3 ~ 4300kcal/m3) 0.5714kgce/m3 ~ 0.6143kgce/m3 Other gas Furnace gas 5227kJ/m3 (1250kcal/m3) 0.1786kgce/m3 Heavy oil catalytic cracking gas 19235kJ/m3 (4600kcal/m3) 0.6571kgce/m3 Heavy oil pyrolysis gas 35544kJ/m3 (8500kcal/m3) 1.2143kgce/m3 Coke gas 16308kJ/m3 (3900kcal/m3) 0.5571kgce/m3 Pressure Coal Gasification 15054kJ/m3 (3600kcal/m3) 0.5143kgce/m3 Water Gas 10454kJ/m3 (2500kcal/m3) 0.3571kgce/m3 Benzol 41816kJ/m3 (10000kcal/m3) 1.4286kgce/m3 Thermal (eq) 0.03412kgce/MJ Electricity (eq) 3600kJ/(kW · h) [8600kcal/(kW · h)] 0.1229kgce/(kW · h) Water as the working fluid energy conversion coefficient 0.4857kgce/t

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 30252-2013_English be delivered?

Answer: Upon your order, we will start to translate GB 30252-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 30252-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB 30252-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information