|
US$334.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19510.2-2009: Lamp controlgear -- Part 2: Particular requirements for starting devices (other than glow starters) Status: Valid GB 19510.2: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 19510.2-2009 | English | 334 |
Add to Cart
|
3 days [Need to translate]
|
Lamp controlgear -- Part 2: Particular requirements for starting devices (other than glow starters)
| Valid |
GB 19510.2-2009
|
| GB 19510.2-2005 | English | 679 |
Add to Cart
|
3 days [Need to translate]
|
Lamp controlgear -- Part 2: Particular requirements for starting devices (other than glow starters)
| Obsolete |
GB 19510.2-2005
|
PDF similar to GB 19510.2-2009
Basic data | Standard ID | GB 19510.2-2009 (GB19510.2-2009) | | Description (Translated English) | Lamp controlgear -- Part 2: Particular requirements for starting devices (other than glow starters) | | Sector / Industry | National Standard | | Classification of Chinese Standard | K74 | | Classification of International Standard | 29.140.99 | | Word Count Estimation | 17,148 | | Date of Issue | 2009-10-15 | | Date of Implementation | 2010-12-01 | | Older Standard (superseded by this standard) | GB 19510.2-2005 | | Adopted Standard | IEC 61347-2-1-2006, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2009 (No. 151 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies special requirements for the following 1000V 50Hz or 60Hz AC power fluorescent and other discharge lamps start device (other than glow starters and triggers). The boot device can produce no more than 100kV start pulse, and with IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, GB 18774, GB 16843, GB 19510. 9, GB 19510. 10 other standards prescribed lights and together with the ballast. This standard does not apply to a glow discharge lamp starter or loaded starting device, or manual manipulation of the boot device. Fluorescent lamps with preheating transformer requirements given by the GB 19510. 9. Performance requirements see GB/T 19655. |
GB 19510.2-2009: Lamp controlgear -- Part 2: Particular requirements for starting devices (other than glow starters) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Lamp controlgear.Part 2. Particular requirements for starting devices (other than glow starters)
ICS 29.140.99
K74
National Standards of People's Republic of China
GB 19510.2-2009/IEC 61347-2-1.2006
Replacing GB 19510.2-2005
Control devices - Part 2 of the lamp.
Starting devices (other than glow starters) - Particular requirements
(IEC 61347-2-1.2006, IDT)
Posted 2009-10-15
2010-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 2 General requirements
5 General test description 2
6 Category 2
7 mark 3
8 accidental contact with live parts of the measures to prevent 3
9 Terminal 3
10 protection grounding device 3
11 Moisture resistance and insulation 3
12 Dielectric strength 3
Heat winding 13 Test 4
14 Fault Status 4
Fever 415 Detached Starters
Voltage trigger pulse 16 5
17 Mechanical strength 5
18 Structure 6
19 creepage distances and clearances 6
20 Screws, current-carrying parts and connections 6
21 heat, fire and resistance to tracking 6
22 corrosion 6
Appendix A (normative) test to determine whether a conductive part is a live part may cause an electric shock. 8
Particular requirements for 8 Appendix B (normative) control device for thermally protected lamp
Particular requirements for electronic control device of the lamp 8 Appendix C (normative) with thermal protector
Annex D (normative) heating test control apparatus for thermally protected lamp of claim 8
Annex F (normative) anti-convection air chamber 9
Derivation of Annex G (normative) values of pulse voltages 9
Annex H (normative) Test 9
Annex I (normative) Mechanical strength test 9
Appendix J (normative) measure spherical discharger Code 10
References 11
GB 19510.2-2009/IEC 61347-2-1.2006
Foreword
All technical content in this section is mandatory.
GB 19510 "Lamp control" is divided into 14 parts.
--- Part 1. General requirements and safety requirements;
--- Part 2. starting devices (other than glow starters) - Particular requirements;
--- Part 3. Tungsten with AC/DC buck converter electronic Particular requirements;
--- Part 4. Particular requirements for the exchange of electronic fluorescent ballasts;
--- Part 5. Particular requirements for dc supplied electronic ballasts for general lighting of;
--- Part 6. Public transport lighting Particular requirements for dc electronic ballasts;
--- Part 7. DC electronic ballasts for aircraft lighting Particular requirements;
--- Part 8. DC electronic ballasts for emergency lighting Particular requirements;
--- Part 9. Particular requirements for ballasts for fluorescent lamps;
--- Part 10. discharge lamps (excluding fluorescent lamps) with the special requirements of the ballast;
--- Part 11. high frequency cold start tubular discharge lamps (neon) Specific requirements for electronic exchange and the frequency converter;
--- Part 12. Particular requirements for lighting and miscellaneous electronic circuits associated with;
--- Part 13. discharge lamps (excluding fluorescent lamps) or AC supplied electronic ballasts for special requirements;
Part --- Article 14. LED module with special requirements for dc or ac electronic control device.
This is Part 2 GB 19510's.
This section should be used with GB 19510.1-2009, it is appropriate in terms of GB 19510.1-2009 supplement or repair
Formulated from the following changes.
This section identical with IEC 61347-2-1.2006 "starting devices (other than glow starters) controlling the lamp Part 2-1
Special requirements "(in English).
For ease of use, this section made the following editorial changes.
a) "IEC 61347-2-1" to "this part", "IEC 61347-2-1 standard number" be replaced by "GB 19510.2";
b) the international standard "(note .)" Remove form in brackets;
"." C) used in place of a decimal point as the decimal point, "";
d) For other international standards referenced it has been adopted as the equivalent of a standard, this part of the country with reference to these national standards
Or industry standards instead of the corresponding international standards, and the rest not tantamount to the adoption of a standard for the international standards in this section are
Direct reference (see Part 2 of this chapter).
This Part replaces GB 19510.2-2005 "Part 2 lamp control device. starting devices (other than glow starters) Special
Claim".
This section compared with GB 19510.2-2005 main differences are as follows.
--- In Chapter 1, the elimination of the range "This section relates only to the world's most needed ballast and lamp starter";
--- Changes in the reference standard normative references, the GB/T 2423.55 changed to GB/T 2423.55-2006, will
GB/T 311.6 voltage measurement recommendation was changed to GB/T 311.6 standard voltage measuring void ball gap (a ground ball);
--- Increase the concept of "trigger" in the definition of 3.1;
--- Added "voltage source" in the definition of 3.5;
--- 3.6 definition deleted "nominal";
--- In the last line in Chapter 12 "1min" is changed to "GB 19510.1-2009 in Chapter 12";
GB 19510.2-2009/IEC 61347-2-1.2006
--- "The value" 14.2 changes to "Ratings";
--- Changed to "test shall be in accordance with GB 19510.1-2009 5.5" in the last line 15;
--- Increase in the 18.2 "mark on if there is marked, the time limit can be extended to 30s";
--- Increasing the sequence number "a), b)" in Figure 1 start of the trigger voltage measurement circuit and the 3 "dielectric loss tangent
(At 10kHz). tanδ≤20 × 10-3 "is changed to" phase angle (at 10kHz). tanδ = 20 × 10-3 ";
--- In Annex I of Chapter 19 to Chapter 20;
--- Change in reference in IEC 60410 for the IEC 60410. 1973.
This section of the Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F, Appendix G, Appendix H, Appendices I and J are normative
appendix.
This part is proposed by the China National Light Industry Council.
This part of the National Electric lighting Standardization Technical Committee (SAC/TC224) centralized.
This section drafted by. National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Fujian JK Yaming Electric Co., Ltd., Foshan City-wide
Electric Lighting Co., Ltd.
Drafters of this section. Mei Li, Yuan Qi, Zhang Quan, Yang Chi district, Cooper rights.
This section was first released in 2005, this revision is the first time.
GB 19510.2-2009/IEC 61347-2-1.2006
Introduction
This section and the various parts constituting the GB 19510.2 ~ GB 19510.14 regulation when referring to GB 19510.1-2009 any provision of
Set the terms and scope of the implementation of the order of the trial, but also provides the necessary additional requirements. GB 19510.2 ~ GB 19510.14 in
Each part is separate, and do not refer to each other.
If this section by "a section in accordance with GB 19510.1-2009 requires," this sentence to refer to the GB 19510.1-2009
A provision requirements, the meaning of this statement is in accordance with all the requirements of this provision, but obviously does not apply to GB 19510.2 ~
Except for the contents of the control device GB 19510.14 specific type of lamp.
GB 19510.2-2009/IEC 61347-2-1.2006
Control devices - Part 2 of the lamp.
Starting devices (other than glow starters) - Particular requirements
1 Scope
This part of GB 19510 specifies the use of 50Hz or 60Hz 1000V ac power fluorescent and other discharge lamps
With starting devices (other than glow starters and triggers) of special requirements. The starting device can generate no more than 100kV start pulse,
And with the IEC 60081, IEC 60188, IEC 60192, IEC 60662, IEC 60901, IEC 61167, GB 18774, GB 16843,
GB 19510.9, GB 19510.10 lamp ballasts and other standards prescribed together.
This section does not apply to glow starters or load discharge lamp starter starting device, or manual manipulation. Fluorescent preheating transformer
The requirements given by the GB 19510.9.
NOTE. glow starter see GB 20550.
Performance requirements see GB/T 19655.
2 Normative references
The following documents contain provisions which, through reference in this Part of GB 19510, constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
This part of GB 19510.1-2009 Chapter 2 of the reference standards and reference the following criteria.
GB/T 311.6-2005 standard high voltage measuring air gap (IEC 60052.2002, IDT)
GB/T 2423.55-2006 Environmental testing for electric and electronic products - Part 2. Environmental Test Test Eh. Hammer tests
(IEC 60068-2-75.1997, IDT)
GB/T 14598.15-1998 Electrical relays - Part 8. Thermal electrical relays (idt IEC 60255-8.1990)
GB 16843 Single-capped fluorescent lamps - Safety requirements (GB 16843-2008, IEC 61199.1999, IDT)
GB 18774 Safety requirements for double-ended fluorescent lamps (GB 18774-2002, idt IEC 61195.1999)
Part 1 GB 19510.1-2009 lamp control apparatus. General and safety requirements (IEC 61347-1.2007, IDT)
GB 20550 fluorescent glow starter (GB 20550-2006, IEC 60155.1993, IDT)
IEC 60188 high pressure mercury lamp
IEC 60192 Low pressure sodium
IEC 60662 HPS
IEC 61167 metal halide lamps
ISO 3864 Safety colors and safety signs
3 Terms and Definitions
This section uses the terms and definitions as well as the following terms and definitions GB 19510.1-2009 given in Chapter 3.
3.1
To start the discharge lamp to provide the required electrical conditions suitable means, such electrical conditions by the device itself or with its lines
GB 19510.2-2009/IEC 61347-2-1.2006
He produced elements together.
3.2
Usually refers to the starting device for fluorescent lamps, the electrodes used to provide the necessary warm-up, and ballast together, and series impedance of an electrical lamp
Pressure shocks.
Note. The release starting voltage pulse starter element may be triggered, for example, the phase angle of the same type of position; or non-trigger type.
3.3
Can be prevented for a long time can not start trying to start a lamp (for example. an electrode has been deactivated lamp) boot device.
Note. "prevent attempts to start" means in the case of starter, disconnect the starting current line, and/or the start line of the current limit is equal to or
Degree is smaller than the rated lamp current.
In the case of using triggers, "to prevent attempts to start" means the occurrence of the pulse has stopped, or voltage pulse amplitude decreased significantly.
3.4
Up
The maximum output voltage pulse at the trigger end is generated.
3.5
Output (in the open state) and the square of the voltage generated by the power supply (same terminal) of the internal impedance than the voltage source.
3.6
Having the same diameter and press the two metal balls installed at a distance, under the conditions specified for the measurement exceeds the peak 15kV
Voltage.
4 General requirements
GB 19510.1-2009 accordance with Chapter 4 requirements.
5 General test description
In accordance with the requirements of GB 19510.1-2009 Chapter 5 as well as the following additional requirements.
5.1 for starting devices having different electrical characteristics of the lamp
Start means for the different electrical characteristics of the lamp, and shall state in the most unfavorable light tested together.
5.2 Number of samples
Shall submit the following number of samples used for testing.
--- Chapter 6 through Chapter 12 and Chapter 15 ~ Chapter 22 requirements specified for the test. a sample;
Chapter 14 --- test requirements specified in. a sample (if necessary, after consultation with the manufacturer, can increase the sample or parts).
Category 6
In accordance with the requirements of GB 19510.1-2009 Chapter 6 as well as the following additional requirements.
The output voltage
The output voltage will start the device classified as follows.
--- 5kV or less (including 5kV);
--- 5kV ~ 10kV (including 10kV);
GB 19510.2-2009/IEC 61347-2-1.2006
--- 10kV ~ 100kV (including 100kV).
7 logo
7.1 Mandatory Signs
According to GB 19510.1-2009 7.2 requirements starting device shall be clearly and permanently marked with the following signs.
Content --- GB 19510.1-2009 in 7.1 a), b), c) and f) prescribed; and
--- Voltage spikes flag that marked the peak voltage exceeds 1500V. Cable having such a voltage should be marked this
Kinds of signs. For more than 5kV pulse voltage trigger, the flag should be a flashing symbol (dotted arrow) (see
ISO 3864).
5kV or more triggers do not need to sign a ground terminal, because this trigger is equipped with a predetermined time limit.
7.2 Supplementary flag
In addition to the mandatory signs, if necessary, should be marked on the following elements starting device, or write to the manufacturer's catalog or similar article
Member.
--- GB 19510.1-2009 in 7.1 d), e), h), i), j), k) and l) of the contents; and
--- Description time limit, if you start with such a device, then the time limit;
--- If this kind of ballast is designed to be able to control the size of the pulse voltage, the ballast shall be marked to start supporting the use of the device and
Catalog number.
Certain conditions on the use of boot device.
8 measures to prevent accidental contact with live parts
GB 19510.1-2009 accordance with the requirements of Chapter 10.
9 Terminals
GB 19510.1-2009 accordance with Chapter 8 requirements.
10 protection grounding device
In accordance with the requirements of GB 19510.1-2009 Chapter 9.
11 Moisture resistance and insulation
In accordance with the requirements of GB 19510.1-2009 Chapter 11 as well as the following requirements.
Without the aid of tools will be able to disassemble the electronic component, the housing and other parts are all removed, if necessary, with the main unit
Humidity treatment pieces together.
In order to make the chamber reaches a predetermined condition, make sure the air inside the loop, the general use of insulated chamber.
For double or reinforced insulation resistance should be not less than 7MΩ.
It should be noted at the wet end of the process, and before measuring the insulation resistance, humidity test sample should not have significant changes.
To achieve this, it is recommended when measuring insulation resistance of the sample will remain in the humidity cabinet, or in the neighboring reservation and with no ventilation
There are similar box with moist conditions indoors.
12 Dielectric strength
In accordance with the requirements of GB 19510.1-2009 Chapter 12 as well as the following requirements.
GB 19510.2-2009/IEC 61347-2-1.2006
Pulse Test
For starting device with a high voltage winding, using the following pulse test their eligibility test. the boot device in the amount of 110%
Under the conditions given supply voltage without lights work until a pulse is 50 times, if necessary, disconnect or power.
Note. high voltage winding means is mounted within the starter and start the lamp to produce the necessary voltage windings.
During the test, the activation means.
a) There should be a clear breakdown or sound discharge (electrical insulation failure under stress signs);
b) There should be no arcing or flashover phenomenon;
c) in the front or rear observed on the oscilloscope a pulse voltage waveform should not have folded or compressed phenomenon.
For starting device without high voltage winding its eligibility by GB 19510.1-2009 a dielectric strength test to Chapter 12
test.
Heat test 13 windings
GB 19510.1-2009 not in accordance with the requirements of Chapter 13, independent testing requirements are still being studied.
14 Fault Status
In accordance with the requirements of Chapter 14 GB 19510.1-2009 and the following additional requirements.
Degree light line when the device is caused by the failure of current rise 14.1 should not start ballast excessive heat, which means that different
Light lines on during the current does not exceed the maximum preheat current IEC 60081 and IEC 60901 specified, may be deemed to meet this
Claim.
14.2 Independent starting devices should not exceed 15.2 requirements as abnormal temperature value. For preheating the lamp electrodes, when the actuating means
When the short-circuit current and the preheating of the added value does not exceed 5% of the rated value, it may be deemed to meet this requirement.
If and when preheating the lamp electrodes is at 110% of rated voltage condition, the current through the ballast circuit current exceeds 105% and
Length 5min or more, you should start the mechanical breaker device jumper.
When the mechanical breaker in line with GB/T corresponding conditions 14598.15-1998, then depending on their compliance with this requirement.
Heating device 15 freestanding start
Detached start device during normal operation and during abnormal operation should not be excessive heat.
NOTE. Built-in starting device according to GB 7000.1 and lamps tested together.
Compliance is checked by the tests of the following.
Normal state is described below using the case of one or more working state.
a) lamp during normal operation;
b) rated current through the starter;
c) actuating means is connected to the power supply, for example, occur during normal operation of the power supply voltage or the lamp voltage;
d) b) and c) the existence of two states simultaneously.
The stand-starting devices mounted in a test corner consists of three wooden fibreboard, which has dark wood fiber paint thickness
15mm ~ 25mm, and simulate two walls and ceiling assembly. The starting device is fixed on the ceiling, and as close as possible
Walls, ceilings beyond some of the other starting means each side should be at least 250mm. The location of the test angle should be as far away from the chamber
The five inner surfaces.
The test shall be conducted in accordance with GB 19510.1-2009 5.5.
GB 19510.2-2009/IEC 61347-2-1.2006
15.1 normal operation
The starting device for normal use is connected to the applicable lamp.
When the lamp is in steady state, by changing the voltage applied to the lamp current regulation to the ratings. Under that condition, the start
Actuating means and lamp work until their temperature reaches a steady state.
Temperature components values should not be prescribed 7000.1-2007 Table 12.1 and Table 12.2 over GB .
Used ballast shall comply with relevant IEC standards, and is consistent with the type of boot device boot lamp.
15.2 abnormal operation
The starting device for normal use is connected to the applicable lamp. To bring light to activate the cathode during the test, or use IEC 60081
IEC 60901 instead of the resistor and the lamp parameters specified in Table. You should also use the launcher applies light and has a maximum power rating
Universal ballast tested.
The flip-flop is not illuminated normal use connection.
In the abnormal state, the flip-flop to operate at 110% of rated voltage conditions until the temperature reaches a stable state, or for
Working time limit of the trigger, until the required time limit or before stop working. After that, the temperature measuring parts
degree. This temperature should not be prescribed in value over 7000.1-2007 tables 12.3 GB .
Starters for completion of these tests and after cooling should meet the following conditions.
Flag a) starting device should remain clear.
b) starting device shall withstand the dielectric strength test of this Part specified in Chapter 12 without being damaged, but the test voltage should be reduced
75% GB 19510.1-2009 value specified in Table 1, it should not be less than 500V.
Voltage trigger pulse 16
When the flip-flop circuit shown in Figure 1 uses at rated voltage and load capacitance of 20pF, maximum pulse voltage (positive
Or negative pulses) should be no greater than 5kV, and should be the maximum pulse voltage dependent lamp parameters specified in the table into account.
If the appropriate lamp data sheet is not otherwise stated, for more than 5kV pulse trigger, when it rated supply voltage and at
The next work load capacitance of 20pF, maximum pulse voltage shall not exceed 1.3 × Up (declared by the manufacturer).
For peak pulse 100kV or less, with an oscilloscope or electrostatic voltmeter to measure. For more than 15kV peak pulses,
Spherical discharger is measured using the method of GB/T 311.6-2005 prescribed measurement and the Appendix to this part of the J.
NOTE. The storage oscilloscope can be used as alternatives 1 and the high voltage electrostatic voltmeter test probe having the following characteristics shown together in a line in use.
--- Input resistance ≥100MΩ;
--- Input capacitance ≤15pF;
--- Interruption frequency ≥1MHz.
If in doubt, use an electrostatic voltmeter to measure as the reference method.
17 Mechanical strength
The starter 17.1 exchangeable start device and can be replaced without tools easily accessible parts shall have adequate mechanical
strength.
--- Quality 100g or less starting devices and components as well as with all the provisions of GB 20550 Dimensions starter should
I. Appendix I accepted Roller tests specified in 2, each sample should withstand 20 drops, and anything that might not appear Movies
Affect its safety damage.
--- Quality 100g or more starting devices and components shall be subject to Appendix I I. 1 under the spring hammer test. Test device
Impact energy 0.35Nm, spring compression is 17mm.
After the test, the sample should not have any damage could impair safety.
GB 19510.2-2009/IEC 61347-2-1.2006
17.2 replaceable device and start the activation means can be replaced without tools easily accessible parts, in addition to withstand the normal insertion
Of torque, it should also bear 0.6Nm torque relative to the axis of the test.
Torque is applied to the top of the metal housing, clamping pins, torque from zero gradually raised by a predetermined value.
After the test, the sample should not have any damage could impair safety.
18 Structure
In accordance with the requirements of GB 19510.1-2009 Chapter 15 as well as the following additional requirements.
18.1 on the starter to start all replaceable unit can be replaced without tools and easily accessible components and equipment should have the
There are levels of insulation requirements (including Ⅱ grade) consistent double or reinforced insulation.
The case could not be triggered lighted lamp structure equipped with 18.2 breaker triggering mechanism in the event, the circuit breaker to enable it to start-up current
Line and/or start-up voltage.
Circuit breaker may be an alternative to to limit the starting current and the starting voltage means the lamp can not be greater than the current through the lamp
10% of the rated current. The whole lamp current line additional components do not have to tolerate higher than the rated current of the lamp load.
Eligibility reference Chapter 14 or Chapter 15 of the test to test.
Pulse voltage exceeding 10kV trigger should be fitted with a device to start working time limit. The device could not be triggered in the event of lamp burning
Case point cut within 3s of the start pulse. If the time limit can be extended to 30s mark on the label. In time limit means cutting lines
After the road, a start pulse is only allowed in a trigger disconnect the power generated when the power is turned on again.
Pulse voltage is greater than 5kV 10kV and less than or equal to the trigger should be fitted with a device to start working time limit. The device should be in
In the 60s of the cutting pulse. After the time limit means the circuit is disconnected, a start pulse triggers only allowed after disconnecting the power energization followed
When generating source.
Compliance is checked by inspection and section 15 of the test to test.
18.3 GB with the glow starter 20550 interchangeable starters should be fitted with radio interference suppression device, the effect of the device should be
Radio interference suppression capacitor results in 7.12 GB 20550 provisions equivalent.
19 creepage distances and clearances
In accordance with the requirements of GB 19510.1-2009 chapter 16.
20 Screws, current-carrying parts and connections
In accordance with the requirements of GB 19510.1-2009 Chapter 17.
21 heat, fire and tracking resistance
GB 19510.1-2009 accordance with the requirements...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19510.2-2009_English be delivered?Answer: Upon your order, we will start to translate GB 19510.2-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 19510.2-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB 19510.2-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 19510.2-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19510.2-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|