US$239.00 · In stock Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19415-2013: Minimum allowable values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps Status: Obsolete GB 19415: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 19415-2013 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Minimum allowable values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps
| Obsolete |
GB 19415-2013
|
| GB 19415-2003 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Limited values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps
| Obsolete |
GB 19415-2003
|
PDF similar to GB 19415-2013
Basic data | Standard ID | GB 19415-2013 (GB19415-2013) | | Description (Translated English) | Minimum allowable values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps | | Sector / Industry | National Standard | | Classification of Chinese Standard | F01 | | Classification of International Standard | 27.010 | | Word Count Estimation | 6,639 | | Older Standard (superseded by this standard) | GB 19415-2003 | | Quoted Standard | GB 16843; GB/T 17262 | | Regulation (derived from) | National Standards Bulletin No. 26 of 2013 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard provides a single-ended fluorescent limit, energy and test methods for evaluating values ??of energy efficiency. Boot device or external boot device using a single-capped fluorescent lamps in this standard applies to preheat cathode equipped |
GB 19415-2013: Minimum allowable values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Minimum allowable values of energy efficiency and evaluating values of energy conservation for single-capped fluorescent lamps
ICS 27.010
F01
National Standards of People's Republic of China
Replacing GB 19415-2003
Single-capped fluorescent lamps energy efficiency of limited value and energy conservation evaluation values
Issued on. 2013-12-18
2014-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
Section 4.2 of this standard are mandatory, the rest are recommended.
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB 19415-2003 "single-ended fluorescent lamps and energy-saving energy efficiency of limited value evaluation value", compared with GB 19415-2003, Lord
To technical changes are as follows.
--- Deleted the original reference standard GB/T 2828 and GB/T 2829, GB 16843 increased as a reference standard;
--- Refined single-ended fluorescent lamp category, and in turn gives the limit value of energy efficiency and energy conservation evaluation values;
--- 2000h Lumen maintenance increased from the original 80% to 82%;
--- Remove the test method chromaticity coordinates of the original Chapter 5;
--- Deleted the original Chapter 6 Inspection rules.
This standard by the National Development and Reform Commission Resource Conservation and Environmental Protection, the Ministry of Industry and Information Technology Energy Saving and Comprehensive Utilization Department proposed.
This standard by the National Standardization Technical Committee for Energy and Management (SAC/TC20) centralized.
This standard drafting units. China National Institute of Standardization, Foshan Electrical and Lighting Co., NVC Lighting Technology Co., Ltd., Xiamen
Door Topstar Lighting Co., Ltd. Zhejiang Chen Hui Lighting Co., Ltd., Zhejiang Sunshine Lighting & Electrical Group Co., Ltd., OSRAM (China)
Lighting Co., Ltd., the National Electric Light Source Quality Supervision and Inspection Center (Shanghai), Zhejiang Lighting Appliance Co., Ltd. Po Shan.
The main drafters of this standard. Xiayu Juan, Wei Bin, Zhang Tieli, Peng Yanyan, Qinbi Fang, Zhangjun Bin, Deng Xuemei, Guo Peng Xin, Chen Ying, Chen Haihong,
Wei Zhen Di, Zhao Yuejin.
This standard replaces the standards previously issued as follows.
--- GB 19415-2003.
Single-capped fluorescent lamps energy efficiency of limited value and energy conservation evaluation values
1 Scope
This standard specifies the limit value of single capped fluorescent lamps, energy conservation evaluation values and test methods for energy efficiency.
This standard applies to the inner cathode equipped with a preheating starting device or using an external single-ended fluorescent lamp starter.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 16843 Safety requirements for single-capped fluorescent lamps
GB/T 17262 Single-capped fluorescent lamps - Performance requirements
3 Terms and Definitions
GB/T 17262 and defined by the following terms and definitions apply to this document.
3.1
The initial single-ended fluorescent light effect initialluminousefficacyforsingle-cappedfluorescentlamps
Test methods, single-ended fluorescent lamps and power measured initial luminous flux ratio according to the standard rules.
3.2
Single-capped fluorescent lamps energy efficiency limit minimumalowablevaluesofenergyefficiencyforsingle-cappedfluorescent
lamps
According to the standard test method for the minimum limit, the initial single-ended fluorescent light effects.
3.3
Single-ended fluorescent energy saving evaluation value evaluatingvaluesofenergyconservationforsingle-cappedfluorescentlamps
Test methods, the initial single-ended fluorescent light efficiency of the energy requirements of the minimum limits prescribed by the standards.
4. Technical Requirements
4.1 Basic requirements
This standard is applicable to single-ended fluorescent lamps, their safety should meet the requirements of GB 16843, the performance should be consistent with GB/T 17262 requirements.
4.2 energy efficiency limit
Single-capped fluorescent lamps energy efficiency of limited value to comply with Table 1.
Table 1 Single-capped fluorescent lamps energy efficiency of limited value and energy conservation evaluation values
Lamp Type Nominal power/W
The initial single-ended fluorescent light effect/(lm/W)
Hue. RR, RZ tone. RL, RB, RN, RD
Energy efficiency of limited value evaluating values of energy efficiency limit value of energy conservation evaluation values
Double Tube
2462706575
2760646368
2863696773
3063696773
3667767081
4067797083
5567777082
8069757278
Four categories
2660646367
2752565459
Multi-Tube
2660646367
3255686075
4255676074
5759686275
6059656269
6259656269
7059686274
8259696275
8559666271
12059686275
Square
Table 1 (continued)
Lamp Type Nominal power/W
The initial single-ended fluorescent light effect/(lm/W)
Hue. RR, RZ tone. RL, RB, RN, RD
Energy efficiency of limited value evaluating values of energy efficiency limit value of energy conservation evaluation values
Square
2156616165
2457636267
2862696673
3662696673
3863696673
Annulus
Φ29 (halogen powder)
Φ29 (tri-phosphor)
Φ16
2244--51--
3248--57--
4052--60--
2255625964
3264706874
4064726876
2272747578
2772797584
3472817587
4069757480
4169817487
5563706675
6063756680
4.3 evaluating values of energy
Single-ended fluorescent energy saving evaluation value should meet the requirements in Table 1.
4.4 Lumen maintenance
Single-capped fluorescent lamps after ignition 2000h, lumen maintenance should not be less than 82%.
5 Test methods
Initial luminous efficacy and lumen maintenance testing and calculated in accordance with GB/T 17262 requirements.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19415-2013_English be delivered?Answer: Upon your order, we will start to translate GB 19415-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 19415-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB 19415-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 19415-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19415-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|