US$439.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 19157-2025: General specification for remote-controlled fire monitor systems Status: Valid GB 19157: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 19157-2025 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
General specification for remote-controlled fire monitor systems
| Valid |
GB 19157-2025
|
| GB 19157-2003 | English | 389 |
Add to Cart
|
3 days [Need to translate]
|
General specification for remote-controlled fire monitor systems
| Valid |
GB 19157-2003
|
Standard similar to GB 19157-2025 GB/T 51033 GB/T 50082
Basic data | Standard ID | GB 19157-2025 (GB19157-2025) | | Description (Translated English) | General specification for remote-controlled fire monitor systems | | Sector / Industry | National Standard | | Classification of Chinese Standard | C84 | | Classification of International Standard | 13.220.01 | | Word Count Estimation | 22,253 | | Date of Issue | 2025-08-01 | | Date of Implementation | 2026-08-01 | | Older Standard (superseded by this standard) | GB 19157-2003 | | Issuing agency(ies) | State Administration for Market Regulation, Standardization Administration of China |
GB 19157-2025: General specification for remote-controlled fire monitor systems---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB19157-2025
ICS 13.220.01
CCSC84
National Standard of the People's Republic of China
Replaces GB 19157-2003
General technical requirements for remote-controlled fire monitor systems
Released on August 1, 2025
Implementation on August 1, 2026
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Classification and Model 2
4.1 Classification 2
4.2 Model 2
5 Performance Requirements 7
5.1 Appearance 7
5.2 Component Performance 7
5.3 Remote Control Fire Monitor System Performance 7
5.4 Wireless Remote Control Performance 10
5.5 Electronic controller performance 10
5.6 Fire pump unit performance 10
5.7 Performance of main components of remote-controlled fire-fighting dry powder monitor system 10
5.8 Performance of main components of remote-controlled firefighting compressed air foam monitor system 11
5.9 Foam Proportioning Device Performance 11
5.10 Fire turret performance 11
5.11 Sign 12
5.12 User Manual 12
6 Test Methods 12
6.1 Appearance Inspection 12
6.2 Component performance test 12
6.3 Remote Control Fire Monitor System Performance Test 12
6.4 Wireless remote control performance test 13
6.5 Electronic controller performance test 14
6.6 Fire pump unit performance test 14
6.7 Performance test of main components of remote-controlled fire-fighting dry powder monitor system 14
6.8 Performance test of main components of remote-controlled fire-fighting compressed air foam monitor system 14
6.9 Foam proportioning device performance test 14
6.10 Fire turret performance test 14
6.11 Sign Check 15
6.12 Instruction Manual Check 15
7 Inspection Rules 15
7.1 Factory Inspection 15
7.2 Type inspection 15
8 Packaging, transportation and storage 16
8.1 Packaging 16
8.2 Transportation 16
8.3 Storage 16
Preface
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents"
Drafting.
This document replaces GB 19157-2003 "General Technical Specifications for Remote Control Fire Monitor Systems". Compared with GB 19157-2003, except for the structural adjustment,
In addition to the integration and editorial changes, the main technical changes are as follows.
a) The terms and definitions have been changed (see Chapter 3, Chapter 3 of the.2003 edition);
b) The classification of remote-controlled fire monitor systems has been changed (see 4.1,.2003 edition);
c) The method for compiling the model of remote-controlled fire monitor systems has been changed (see 4.2, 4.2 of the.2003 edition);
d) Added appearance performance requirements for electroplated parts (see 5.1.4);
e) Added component performance requirements and test methods (see 5.2, 6.2);
f) Added performance requirements and test methods for remote-controlled fire monitors, and changed the spray performance requirements and test methods for operational-controlled fire monitor systems.
(See 5.3, 6.3);
g) The performance parameters have been changed to include them as part of the performance requirements (see 5.3, Chapter 5 of the.2003 edition);
h) The water pressure strength performance requirements and test methods have been changed (see 5.2.2, 6.2.2, and 6.7.4 and 7.2 of the.2003 edition);
i) The requirements and test methods for the performance of remote-controlled fire monitor spray systems have been modified (see 5.3, 6.3, Chapter 5 of the.2003 edition);
j) The requirements and test methods for the performance of wireless remote controls have been changed (see 5.4, 6.4, and 5.6, 6.6 of the.2003 edition);
k) The requirements and test methods for the performance parameters of electronic controllers have been changed (see 5.5 and 6.5 of the.2003 edition);
l) Added the requirements for the performance parameters of remote-controlled fire-fighting dry powder monitor systems (see 5.7);
m) Added the requirements for the performance parameters of remote-controlled fire-fighting compressed air foam monitor systems (see 5.8);
n) The requirements and test methods for the performance parameters of the foam proportioning device have been changed (see 5.9 and 6.9 of the.2003 edition);
o) The requirements for the performance parameters of fire turrets have been modified (see 5.10, 5.7 and 6.7 of the.2003 edition).
Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.
This document is proposed and coordinated by the National Fire and Rescue Administration.
The previous versions of this document and the documents it replaces are as follows.
---First issued in.2003 as GB 19157-2003;
---This is the first revision.
General technical requirements for remote-controlled fire monitor systems
1 Scope
This document defines the terms and definitions of remote control fire monitor systems, gives classifications and models, and specifies performance requirements, inspection rules and package
The packaging, transportation and storage requirements are described, and the corresponding test methods are described.
This document applies to the design, manufacture and inspection of various remote-controlled fire monitor systems.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
GB/T 1173 Cast aluminum alloys
GB/T 1176 Cast copper and copper alloys
GB/T 1348 Ductile iron castings
GB/T 2423.3 Environmental testing Part 2.Test methods Test Cab. Steady state damp heat test
GB/T 2423.10 Environmental testing Part 2.Test methods Test Fc. Vibration (sinusoidal)
GB/T 3836.2 Explosive atmospheres Part 2.Equipment protected by flameproof enclosure "d"
GB/T 4208-2017 Degrees of protection provided by enclosures (IP code)
GB 6245 Fire Pump
GB 7956.6 Fire trucks Part 6.Compressed air foam fire trucks
GB/T 9439 Grey iron castings
GB 16668 General technical requirements for dry powder fire extinguishing systems and components
GB/T 17626.3 Electromagnetic compatibility test and measurement techniques Part 3.Radio frequency electromagnetic field radiated immunity test
GB 19156-2019 Fire Monitor
GB.20031 Foam fire extinguishing equipment
3 Terms and Definitions
The terms and definitions defined in GB 19156-2019 and the following apply to this document.
3.1
It is composed of a fixed fire extinguishing agent supply source, a drive component, a delivery pipeline, a spray component, and a control device that can remotely control the direction of the fire monitor.
A fixed fire extinguishing system that sprays fire extinguishing agents to extinguish fires on protected objects.
3.2
A remote-controlled fire monitor system consists of a remote-controlled fire monitor, fire monitor turret, power source, control device, fire pump group, etc.
3.3
It is composed of remote-controlled fire foam monitor, fire turret, power source, control device, fire extinguishing agent storage tank (tank), mixing device, fire pump group, etc.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 19157-2025_English be delivered?Answer: Upon your order, we will start to translate GB 19157-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 19157-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB 19157-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 19157-2025?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 19157-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|