US$809.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 17465.4-2015: [GB/T 17465.4-2015] Appliance couplers for household and similar general purposes -- Part 2-4: Couplers dependent on appliance weight for engagement Status: Valid GB 17465.4: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 17465.4-2015 | English | 809 |
Add to Cart
|
6 days [Need to translate]
|
[GB/T 17465.4-2015] Appliance couplers for household and similar general purposes -- Part 2-4: Couplers dependent on appliance weight for engagement
| Valid |
GB 17465.4-2015
|
| GB/T 17465.4-2015 | English | 629 |
Add to Cart
|
6 days [Need to translate]
|
Appliance couplers for household and similar general purposes -- Part 2-4: Couplers dependent on appliance weight for engagement
| Valid |
GB/T 17465.4-2015
|
| GB 17465.4-2009 | English | 919 |
Add to Cart
|
6 days [Need to translate]
|
Appliance couplers for household and similar general purposes -- Part 2: Couplers dependent on appliance weight for engagement
| Obsolete |
GB 17465.4-2009
|
PDF similar to GB 17465.4-2015
Basic data | Standard ID | GB 17465.4-2015 (GB17465.4-2015) | | Description (Translated English) | [GB/T 17465.4-2015] Appliance couplers for household and similar general purposes -- Part 2-4: Couplers dependent on appliance weight for engagement | | Sector / Industry | National Standard | | Classification of Chinese Standard | K65 | | Classification of International Standard | 75.160.20 | | Word Count Estimation | 31,332 | | Date of Issue | 2015-05-15 | | Date of Implementation | 2016-06-01 | | Older Standard (superseded by this standard) | GB 17465.4-2009 | | Quoted Standard | GB 1002; GB/T 4207-2012; GB 4706.1-2005; GB/T 5013.1; GB/T 5013.2; GB/T 5013.3; GB/T 5013.4; GB/T 5013.5; GB/T 5013.6; GB/T 5013.7; GB/T 5023.1; GB/T 5023.2; GB/T 5023.3; GB/T 5023.4; GB/T 5023.5; GB/T 5023.6; GB/T 5023.7; GB/T 5169.5-2008; GB/T 5169.11; GB/T 5169.12; GB/T 5169.13; GB/T 5169.16; GB/T 5169.21; GB/T 8332; GB 14536.1; GB 14536.3; GB 14536.4; GB 14536.5; GB 14536.6; GB 14536.7; GB 14536.8; GB 14536.9; GB 14536.10; GB 14536.11; GB 14536.12; GB 14536.13; GB 14536.15; GB 14536.16; GB 14536.17; GB 14536.18; GB 14536.19; GB 14536.20; GB 14536.21; GB 15092.1; GB/T 16842-2008; GB/T 16935.1-2008; GB 17465.1-2009; GB 17465.2; GB 17465.3; IEC/TR 60083 | | Adopted Standard | IEC 60320-2-4-2009, MOD | | Regulation (derived from) | National Standard Announcement 2015 No. 15 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the couplers dependent on appliance weight for engagement structure, mechanical properties, electrical properties and other technical requirements. This section applies to household and similar purposes, with or without ground contact, and plan to built or integrated AC power frequency of 50 Hz or 60 Hz rated voltage not exceeding 250 V, rated current not exceeding 16 A electrical or other electrical equipment within a multi-component structure, and rely on the weight of the appliance to ensure correct polarization appliance coupler engagement. |
GB 17465.4-2015: [GB/T 17465.4-2015] Appliance couplers for household and similar general purposes -- Part 2-4: Couplers dependent on appliance weight for engagement ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Appliance couplers for household and similar general purposes Part 2-4. Couplers dependent on appliance weight for engagement
ICS 29.120.20
K65
National Standards of People's Republic of China
Replacing GB 17465.4-2009
Household and similar appliances couplers
Part 2-4. dependent on appliance weight for engagement coupler
Part 2-4. Couplersdependentonapplianceweightforengagement
(IEC 60320-2-4.2009, MOD)
Issued on. 2015-05-15
2016-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 3 General requirements
5 General notes 3
6 Standard Rating 3
7 Category 4
8 Flag 4
9 Dimensions and interchangeability 5
10 Protection against electric shock 6
11 grounding 6
12 Terminals and terminations 6
13 Structure 6
14 moisture 8
15 Insulation resistance and electric strength 8
16 connector insertion and removal force required 9
17 contacts work 10
18 for heat resistance appliance couplers for hot conditions and very hot conditions 10
19 Breaking capacity 10
Normal operation 20 11
21 11 temperature
22 and its connecting cord 12
Mechanical strength 23 13
24 heat-resistant and anti-aging properties 13
25 Screws, current-carrying parts and connections 14
26 creepage distances, clearances and distances through insulation 14
27 heat-resistant insulating material, fire resistance and electrical traces of 18
28 rust 19
29 Electromagnetic compatibility (EMC) requirements 19
Appendix A (normative) factory wired appliance couplers related to safety aspects of routine tests (protection against electric shock and correct
Polarity) 20
Means 21 Appendix B (normative) 14.2 for test
Annex C (normative) proof tracking test 22
Annex D (normative) Needle flame test 23
References 24
Figure 1 Example 19 clearances
Figure B.1 means 21 for 14.2 Test
Table 1 test voltage 9
Table 2 cords of the model and the minimum nominal cross-sectional area 12
Table 3 minimum clearance 15
Table 4 rated impulse voltage 15
Table 5 minimum basic insulation creepage distance 17
Foreword
GB 17465 All technical content in this section is mandatory.
GB 17465 "Household and similar appliances couplers" or has plans to release the following sections.
--- Part 1. General requirements.
--- Part 2. Special requirements.
● Part 2-1. Sewing machine couplers;
● Part 2-2. Household and similar equipment interconnection couplers;
● Part 2-3. protection higher than IPX0 appliance couplers;
● Part 2-4. dependent on appliance weight for engagement coupler.
This part of GB 17465 Part 2-4.
This section drafted in accordance with GB/T 1.1-2009 given rules.
17465.4-2009 "Household and similar appliances - Part 2 couplers partially replace GB . coupled by appliance weight for engagement
Clutch. "
This section compared with GB 17465.4-2009, the main changes are as follows.
--- Modify the first two dashes 5.5 contents;
--- Paragraph 3 5.5, 7.1 "anti-overflow protection" with "having a liquid spill protection measures";
--- An increase of 7.6;
--- 8.1 weight increased engagement type connector rated current, rated voltage marking requirements;
--- 8.2 adds support for the rated current weight intermeshing appliance inlet rated voltage marking requirements;
--- Deleted 8.5, revised 8.6, adds new requirements;
--- Revised 10.1;
--- Increased 10.2;
--- Increased 10.5;
--- Increased 12.3;
--- Revised 14.2;
--- Modify the table 101 (Table 1 edition) test voltage in between live parts and accessible parts and live parts of isolation;
--- 16.1 Paragraph 1 determines the minimum weight of the modified full engagement approach;
--- Revised Chapter 18;
--- Chapter 19 adds two annotations;
--- Chapter 20 modifies the normal operation of the test method, in order to be consistent with the standard machine;
--- Chapter 21 clearly heating test requirements can use the relevant electrical standards and increase the Note 2;
25.8 --- deleted, added new requirements;
--- Chapter 26 clearly under the weight of intermeshing engagement and appliance inlet is not connected to the case engages weight intermeshing
Is tested;
--- 26.3 complements the solid insulation of the content;
--- Added Appendix B.
This section uses redrafted law revision adopted IEC 60320-2-4.2009 section "Household and similar appliances couplers 2-4.
Appliance weight for engagement by the coupler. "
This part of IEC 60320-2-4.2009 technical differences and their reasons are as follows.
--- According to China's geographical and climatic environment, the provisions of the product temperature of the environment is "usually not more than 35 ℃, but occasionally reaching 40 ℃",
To be consistent with GB 17465.1-2009. IEC 60320-2-4.2009 in a predetermined ambient temperature is "usually not more than
25 ℃, but occasionally reaching 35 ℃ ".
--- On normative references, this part has been adjusted technical differences, in order to adapt our technical conditions, the adjusted situation
Focus is reflected in the status of Chapter 2, "Normative references", the specific adjustments are as follows.
● measurement method GB/T 4207-2012 solid insulating materials resistance to tracking index and comparative tracking index
(IEC 60112.2009, IDT) instead of IEC 60112;
● with GB 4706.1-2005 Safety of household and similar electrical appliances - Part 1. General requirements (IEC 60335-1.
2004, IDT) instead of IEC 60335-1;
● with the GB/T 5169.5-2008 Fire hazard testing for electric and electronic products - Part 5. Test flames - Needle-flame test side
Law means, confirmatory test arrangement and guidance (IEC 60695-11-5.2004, IDT) instead of IEC 60695-11-5;
● with the GB/T 5169.16 Fire hazard testing for electric and electronic products - Part 16. Test flames - 50W horizontal and vertical
Direct flame test methods (GB/T 5169.16-2008, IEC 60695-11-10.2003, IDT) instead of the IEC 60695-
11-10;
● Because 24.1.3 references GB/T 5169.21, thus increasing the GB/T 5169.21 electric and electronic products in Chapter 2
Fire hazard testing - Part 21. Abnormal heat - Ball pressure test (GB/T 5169.21-2006, IEC 60695-10-2.
2003, IDT);
● with GB 14536 (all parts) for household and similar use automatic controller [IEC 60730 (all parts)] in place
IEC 60730 (all parts);
● with GB 15092.1 Switches for appliances - Part 1. General requirements (GB 15092.1-2010, IEC 61058-1Ed.3.2.
2008, IDT) instead of IEC 61058-1;
● with the GB/T 16842-2008 housing for people and equipment protection test with a test (IEC 61032.1997, IDT) on behalf of the
For IEC 61032;
● with an insulating inner GB/T 16935.1-2008 low voltage systems for equipment - Part 1. Principles, requirements and tests
(IEC 60664-1.2007, IDT) instead of IEC 60664-1;
● with GB 17465.1-2009 household and similar appliances couplers - Part 1. General requirements (IEC 60320-1.
2007, MOD) instead of IEC 60320-1;
● with GB 17465.2 household and similar appliances couplers - Part 2. Household and similar equipment interconnection couplers
(GB 17465.2-2009, IEC 60320-2-2.1998, MOD) instead of IEC 60320-2-2;
● with GB 17465.3 household and similar appliances couplers - Part 2. protection higher than IPX0 of appliance couplers
Device (GB 17465.3-2008, IEC 60320-2-3.2005, IDT) instead of IEC 60320-2-3;
● GB 1002 increase of household and similar single-phase plugs and socket type, basic parameters and dimensions.
--- In order to ensure correct use of coupling products, an increase of 8.1 and 8.2 weight intermeshing connector type and weight for engagement
Appliance inlet rated current, rated voltage marking requirements.
--- In order to adapt the coupler product on the whole product in actual use, consistent with the relevant requirements of the whole product standards, the Senate
According to the provisions of GB 4706.2-2007 and GB 4706.19-2008, the revised test methods Chapter 20 normal operation.
This part made the following editorial changes.
--- Writing style according to GB/T 1.1 requirements, section numbers in this section compared to IEC 60320-2-4.2009 has been adjusted;
--- According to GB/T 1.1 relevant provisions in Chapter 1, "Scope" supplemented "GB 17465 of the provisions of this part of the appliance by weight Nie
Coupler combination of structural, mechanical properties, electrical properties and other technical requirements ";
--- For ease of understanding, an increase of 3.8 non-rewirable electrical accessories;
14.2 --- because trials require three additional specimens, 5.5 second dash in the "Chapter 14" is replaced by "14.1";
--- Remove the IEC 60320-2-4.2009 Some comments apply to other countries, such as 8.6 Note 3.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the standard by the National Electric annex Standardization Technical Committee (SAC/TC67) centralized.
This section drafted by. China Electric Apparatus Research Institute Co., Strix (Guangzhou) Electric Co., Ltd., Guangdong Entry-Exit Inspection
Quarantine Bureau Inspection and Quarantine Technology Center, known Ningbo Ou Electrical Technology Co., Ltd., Hangzhou Hongyan Electric Co., Ltd., the Bulls Group Ltd., Yue
China Holdings Limited, Guangzhou Panyu Tianhong Industrial Development Co., Weikai Detection Technology Co., Ltd. Ao Thai thermostat (Shenzhen)
Limited.
The main drafters of this section. Cai Jun, Zhou Juan, Jiang Hua, thanks Ke Long, Jinfeng, Ruan Liping, holy dynasty, Li Dajian, a high hope, sail, Caiying Feng,
Luo Shiming.
This part of the standard replaces the previous editions are.
--- GB 17465.4-2009.
Household and similar appliances couplers
Part 2-4. dependent on appliance weight for engagement coupler
1 Scope
GB 17465 of the provisions of this part of the structure, mechanical properties, electrical properties couplers dependent on appliance weight for engagement of other technical requirements.
This section applies to household and similar purposes, with or without ground contact, and plan to built or integrated AC power frequency of 50Hz
Or 60Hz, rated voltage not exceeding 250V, rated current not exceeding electrical equipment, electrical or other multi-component structure. 16A, and in accordance with
By weight of the appliance to ensure the correct poles appliance coupler engagement.
Note 1. compliance with appliance couplers of this section apply to the use of the appliance ambient temperature is usually not more than 35 ℃, but occasionally reaching 40 ℃ environment 1). But is
A coupler surroundings temperature may exceed this value specified by the manufacturer and to the statement. Appliance inlets and connectors maximum operating environment
Temperature may be different.
Note 2. In normal use, the appliance weight for engagement by appliance couplers may be subjected to overflow liquid. When installed in accordance with manufacturer's instructions for installation,
Depending on whether a liquid overflow protection measures, appliance couplers for classification.
Note 3. GB 17465.1-2009 standard leaflet C1 ~ C23 does not apply to rely on appliance weight for engagement appliance couplers.
Note 4. The following situations may require special structure.
--- In place special conditions, for example, ship, vehicle and similar establishments;
--- In dangerous situations, for example, in a potentially explosive situations occur.
1) consideration of geographical and climatic environment and therefore require the use of ambient temperature is "usually not more than 35 ℃, but occasionally reaching 40 ℃", with the GB 17465.1-
2009 consensus. IEC 60320-2-4.2009 Note the specified ambient temperature is "usually not more than 25 ℃, but occasionally reaching 35 ℃".
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 1002 Household and similar single-phase plugs and socket type, basic parameters and dimensions
GB/T 4207-2012 solid insulating materials resistance to tracking index and comparative tracking index measurement method (IEC 60112.2009,
IDT)
GB 4706.1-2005 household and similar electrical appliances - Safety - Part 1. General requirements (IEC 60335-1.2004, IDT)
GB/T 5013 (all parts) rated voltage 450/750V and below rubber insulated cables [IEC 60245 (all parts)]
GB/T 5023 (all parts) rated voltage 450/750V and below PVC insulated cables [IEC 60227 (all parts)]
GB/T 5169.5-2008 Fire hazard testing for electric and electronic products - Part 5. Test flames - Needle-flame test method means
Confirmatory test arrangement and guidance (IEC 60695-11-5.2004, IDT)
GB/T 5169.11 Fire hazard testing for electric and electronic products - Part 11. Glowing/hot wire based test methods for finished burning
Hot wire flammability test method (GB/T 5169.11-2006, IEC 60695-2-11.2000, IDT)
GB/T 5169.12 Fire hazard testing for electric and electronic products - Part 12. Glowing/hot wire based test methods for materials burning
Hot wire flammability index (GWFI) test method (GB/T 5169.12-2013, IEC 60695-2-12.2010, IDT)
GB/T 5169.13 Fire hazard testing for electric and electronic products - Part 13. Glowing/hot wire based test methods for burning of the material
Ignition temperature (GWIT) Test methods for hot wire from the (GB/T 5169.13-2013, IEC 60695-2-13.2010, IDT)
GB/T 5169.16 Fire hazard testing for electric and electronic products - Part 16. Test flames - 50W horizontal and vertical flame test
The method (GB/T 5169.16-2008, IEC 60695-11-10.2003, IDT)
GB/T 5169.21 Fire hazard testing for electric and electronic products - Part 21. Abnormal heat - Ball pressure test (GB/T 5169.21-
2006, IEC 60695-10-2.2003, IDT)
GB/T 8332 foam combustion behavior of horizontal burning method (GB/T 8332-2008, ISO 9772.2001, IDT)
GB 14536 (all parts) for household and similar use automatic controller [IEC 60730 (all parts)]
GB 15092.1 Switches for appliances - Part 1. General requirements (GB 15092.1-2010, IEC 61058-1.2008, IDT)
GB/T 16842-2008 protective shell for inspection and test equipment used with (IEC 61032.1997, IDT)
GB/T 16935.1-2008 within low-voltage systems Insulation coordination for equipment - Part 1. Principles, requirements and tests (IEC 60664-1.
2007, IDT)
GB 17465.1-2009 household and similar appliances couplers - Part 1. General requirements (IEC 60320-1.2007,
MOD)
GB 17465.2 household and similar appliances couplers Part 2. Household and similar equipment interconnection couplers (GB 17465.2-
2009, IEC 60320-2-2.1998, MOD)
GB 17465.3 Appliance couplers for household and similar purposes Part 2. protection higher than IPX0 appliance couplers
(GB 17465.3-2008, IEC 60320-2-3.2005, IDT)
IEC /T R60083 IEC member countries standardized household and similar use plug and socket (Plugsandsocket-outlets
fordomesticandsimilargeneralusestandardizedinmembercountriesofIEC )
3 Terms and Definitions
GB 17465.1-2009 defined in the following terms and definitions apply to this document.
3.1
Weight engagement coupler weight-engagedcoupler
One kind being built or integrated on the appliance, relying on the weight of the appliance to ensure the correct function of the coupler engagement.
NOTE. The weight of engaging a coupler is used in an apparatus consisting of two parts, the means for connecting to a power supply from the base to perform the function of the appliance components
(Feature) power supply.
3.2
Weight engaging connector weight-engagedconnector
For power connections and associated weight engaged appliance inlet coupler engagement member.
3.3
Weight intermeshing appliance inlet weight-engagedapplianceinlet
Or intend to integrate the contents and function of the parts of the appliance, the weight of the engagement coupler engagement with the associated appliance connector meshing
part.
3.4
Rewirable weight for engagement connectors rewirableweight-engagedapplianceconnector
The structure can replace the power cord connector engages weight.
Note 1. The power cord connection method, when installed according to the manufacturer's installation instructions, X-type or Y-type connection according to appliance standards to classify.
Note 2. X and Y types of connection method requirements see GB 4706.1-2005.
3.5
X-type connector typeXattachment
Connections can be easy to replace the power cord.
Note. The power supply cord may be specially prepared and only from the manufacturer or its service agency obtained at. Specially prepared cord may also comprise an appliance
section.
3.6
Y connector typeYattachment
Intended by the manufacturer, or a service or similar qualified personnel to replace the power cord connection method.
3.7
Z-connection typeZattachment
Not broken or damaged appliance connection method can not replace the power cord.
3.8
Electrical accessories rewirable non-rewirableelectricalaccessory
After connection and assembly by the electrical accessories manufacturer in the structure and form an integral flexible cable electrical accessories.
4 General requirements
According to GB 17465.1-2009 provisions of Chapter 4.
General Description 5 tests
5.1 according to the provisions of GB 17465.1-2009 5.1.
5.2 Sample in accordance with the manufacturer's installation instructions specified delivery status and tested under normal conditions of use; AC 50Hz or
60Hz power supply test.
Non-rewirable weight engagement connectors should be accompanied by at least 1m long cords.
The need to follow the manufacturer's instructions to install the weight engaging connectors and appliance inlets weight intermeshing test strips
Paragraph shall provide representative apparatus or components.
5.3 according to the provisions of GB 17465.1-2009 5.3.
5.4 GB 17465.1-2009 according to the provisions of 5.4.
5.5 to the weight of mesh type appliance inlet requirements for three specimens subjected to the tests specified.
For weight intermeshing connector requires six samples tested.
--- Group 13 specimens subjected except Chapter 14, Chapter 15, Chapter 16, Chapter 19, Chapter 20 and Chapter 21, 24.2 out of a predetermined
Test;
--- Group 23 samples subjected to 14.1, Chapter 15, Chapter 16, Chapter 19, Chapter 20, Chapter 21 and 25.8 (including Chapter 16
Repeat test) requirements.
For claiming a liquid spill protection measures the weight of mesh type connector requires three additional specimens are subjected to the tests specified in 14.2.
The elastic engagement connectors or weight of the thermoplastic material, you need two additional specimens subjected to the applicable GB 17465.1-2009
24.2.1 and 24.2.2 of the test.
For non-rewirable weight for engagement with a connector indicator, the indicator requires a three-pole disconnection of additional samples for
Chapter 15 of the test.
5.6 according to the provisions of GB 17465.1-2009 5.6.
5.7 according to the provisions of GB 17465.1-2009 5.7.
5.8 Routine tests specified in Appendix A.
6 Standard ratings
6.1 standard rated voltage is 250V. Other rated voltage can be declared by the manufacturer, but should not exceed 250V.
6.2 rated current value shall be declared by the manufacturer. Coupler in a particular application use can have different current ratings, rated power
Flow in any case should not exceed 16A.
It meets the requirements of 6.1 and 6.2, by observing the mark or manufacturer's installation and operating instructions to be checked.
Category 7
7.1 According to the connector installed in accordance with manufacturer's instructions, whether protective measures classified spillage.
7.2 Classification by type of connected devices.
--- Ⅰ class device appliance couplers;
--- Ⅱ type of equipment appliance coupler.
Note. The description of categories see GB/T 17045-2008.
7.3 Press couplers whether engaged or not engaged classified under energized conditions.
7.4 Press couplers maximum operating ambient temperature classification.
7.5 according to the number of tests done in Chapter 20 of the periodic classification.
Preferred values.
--- 100000
--- 60000
--- 30000
--- 20000
--- 10000
--- 6000
Note. the same couplers different current ratings can declare a different number of endurance cycles. A cycle consists of two Chapter 19 of the trip, namely
After the connection is disconnected once a second.
7.6 Record the following information is required to cover the test.
--- According to a predetermined minimum cross-section wire;
--- The maximum capacity Xu Duanzi temperature;
--- The maximum permissible end temperature;
--- The maximum allowable contact temperature;
--- According properly engaged the minimum weight required for the appliance;
--- Minimum base weight for engagement required under properly disconnect;
--- According to the bottom of the corresponding appliance inlet plug pin Maximum temperature.
● cold conditions of use appliance couplers (pin temperature not exceeding 70 ℃);
● thermal conditions of appliance couplers (pin temperature not exceeding 120 ℃);
● In hot state used appliance couplers (pin temperature not exceeding 155 ℃).
Note. The temperature rise limit applies to both sockets and connectors, if necessary, may require separately.
8 flag
Shall be marked with the manufacturer or vendor name, trademark or identification mark and models on 8.1 wt engaging connectors.
Manufacturer's instructions due weight mesh type connector rated current, rated voltage, the current and voltage values declared by the manufacturer.
8.2 wt intermeshing appliance inlet shall be marked with the manufacturer or vendor name, trademark or identification mark and model.
Manufacturer's instructions due weight ...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 17465.4-2015_English be delivered?Answer: Upon your order, we will start to translate GB 17465.4-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 17465.4-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB 17465.4-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 17465.4-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 17465.4-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|