HOME   Cart(1)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB 16916.21-2008 English PDF

US$159.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 16916.21-2008: [GB/T 16916.21-2008] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 21: Applicability of the general rules to RCCB functionally independent of line voltage
Status: Valid

GB 16916.21: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 16916.21-2008English159 Add to Cart 3 days [Need to translate] [GB/T 16916.21-2008] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 21: Applicability of the general rules to RCCB functionally independent of line voltage Valid GB 16916.21-2008
GB 16916.21-1997English239 Add to Cart 3 days [Need to translate] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB). Part 2. 1: Applicability of the general rules to RCCB functionally independent of line voltage Obsolete GB 16916.21-1997

PDF similar to GB 16916.21-2008


Standard similar to GB 16916.21-2008

GB/T 14048.5   GB/T 14048.6   GB 16916.1   GB 16917.1   GB 16917.21   GB 16917.22   

Basic data

Standard ID GB 16916.21-2008 (GB16916.21-2008)
Description (Translated English) [GB/T 16916.21-2008] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 21: Applicability of the general rules to RCCB functionally independent of line voltage
Sector / Industry National Standard
Classification of Chinese Standard K31
Classification of International Standard 29.120.50
Word Count Estimation 6,623
Date of Issue 2008-06-19
Date of Implementation 2009-06-01
Older Standard (superseded by this standard) GB 16916.21-1997
Adopted Standard IEC 61008-2-1-1990, IDT
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Chinese standard is suitable for AC rated voltage not exceeding 440V, rated current not exceeding 125A is mainly used for protection against electric shock function and operation of the supply voltage off for household and similar purposes without integral overcurrent protection for residual current operated circuit breaker (RCCB).

GB 16916.21-2008: [GB/T 16916.21-2008] Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) -- Part 21: Applicability of the general rules to RCCB functionally independent of line voltage



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB) .Part 21. Applicability of the general rules to RCCB functionally independent of line voltage ICS 29.120.50 K31 National Standards of People's Republic of China GB 16916.21-2008/IEC 61008-2-1.1990 Replacing GB 16916.21-1997 Household and similar purposes without overcurrent protection Residual current operated circuit breaker (RCCB) Part 21. General rules for the operation of the function Applicability of the power supply voltage independent RCCB (IEC 61008-2-1.1990, IDT) Posted 2008-06-19 2009-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

All technical content in this section is mandatory. GB 16916 "Household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB)" divided into the following section. --- Part 1. General rules; --- Part 21. General rules for the operation of the functions independent of line voltage RCCB applicability; --- Part 22. General rules for the operation of the function and line voltage RCCB applicability. This section GB Part of 2,116,916. This section identical with IEC 61008-2-1.1990 "Household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB) - Part 2.1. General rules for the operation of the functions independent of line voltage RCCB applicability. " This section should be used and GB 16916.1-2003 "household and similar purposes without overcurrent protection RCBO (RCCB) - Part 1. General rules "together. This Part replaces GB 16916.21-1997, the main difference between this part and GB 16916.21-1997 follows. --- The whole standard "line voltage" to "supply voltage"; --- Chapter 6 "n) item" to "m) item"; --- The "9.11.2.1a) the last two" to "9.11.2.1a) last paragraph." This part is proposed by the China Electrical Equipment Industrial Association. The low-voltage electrical part by the National Standardization Technical Committee (SAC/TC189) centralized. This section is responsible for drafting unit. Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd. Participated in the drafting of this section. Schneider Electric (China) Investment Co., Ltd. The main drafters of this section. Zhou Gang plot, Liu Jinyan, Chen Ying. The partial participation drafters. Nguyen Tao. This part of the standard replaces the previous editions are. --- GB 16916.21-1997. GB 16916.21-2008/IEC 61008-2-1.1990

Introduction

Part of GB 2116916 (ie GB 16916.21) is the corresponding provisions of Part 1 (ie GB 16916.1) supplement or repair To change, to accommodate motor function independent of supply voltage of the RCCB. GB 16916.21-2008/IEC 61008-2-1.1990 Household and similar purposes without overcurrent protection Residual current operated circuit breaker (RCCB) Part 21. General rules for the operation of the function Applicability of the power supply voltage independent RCCB

1 Scope

Except for the following modifications, Part 1 applies. Instead of the first paragraph with the following. The operation of this section applicable to the exchange rated voltage not exceeding 440V, rated current not exceeding 125A is mainly used for protection against electric shock Function independent of the supply voltage for household and similar uses overcurrent protection for residual current operated circuit breaker (RCCB).

2 Normative references

The following documents contain provisions which, through reference in this Part of GB 16916, constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. Part 1 of this clause apply.

3 Terms and Definitions

In addition to Part 1 of 3.3.5,3.4.10 NA, the other are applicable. Category 4 In addition to 4.1.2, Part 1 provisions apply.

5 RCCB features

Except for the last two lines of 5.1 is not applicable, the provisions of Part 1 applies.

6 logos and other product data

Apart) m NA item, the Part 1 provisions apply.

7 and the standard conditions of installation

Part 1 provisions apply.

8 Structure and operating requirements

In addition to 8.12 NA, the provisions of Part 1 applies.

9 Test

In addition to the following, in part 1 of this clause apply. 9.1.1 in Table 7, line 15 (about 9.17 Test) Not applicable. GB 16916.21-2008/IEC 61008-2-1.1990 9.7.4 Note 3 does not apply. 9.9.5 Not applicable. 9.11.2.1a) last paragraph and i) the last paragraph does not apply. 9.17 Not applicable. Last paragraph 9.18.1 and 9.18.2 do not apply. Part 1 would apply. appendix In addition to Appendix A, Table A. 1 in terms of "working conditions 9.17 supply voltage fault" (test sequences D.1) NA and Annex IB The last two symbols NA, the other contents of the first section of the appendix apply. GB 16916.21-2008/IEC 61008-2-1.1990

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 16916.21-2008_English be delivered?

Answer: Upon your order, we will start to translate GB 16916.21-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 16916.21-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB 16916.21-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 16916.21-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 16916.21-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.