US$419.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 16636-2008: Code of safety for driver use of electricity underwater Status: Valid GB 16636: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 16636-2008 | English | 419 |
Add to Cart
|
3 days [Need to translate]
|
Code of safety for driver use of electricity underwater
| Valid |
GB 16636-2008
|
| GB 16636-1996 | English | 559 |
Add to Cart
|
4 days [Need to translate]
|
Technical regulations for diversafe use of electricity under water
| Obsolete |
GB 16636-1996
|
Standard similar to GB 16636-2008 GB 20826
Basic data | Standard ID | GB 16636-2008 (GB16636-2008) | | Description (Translated English) | Code of safety for driver use of electricity underwater | | Sector / Industry | National Standard | | Classification of Chinese Standard | R54 | | Classification of International Standard | 03.220.40; 13.100 | | Word Count Estimation | 18,137 | | Date of Issue | 2008-06-19 | | Date of Implementation | 2009-01-01 | | Older Standard (superseded by this standard) | GB 16636-1996; GB 17869-1999 | | Quoted Standard | GB 6722; GB/T 16560 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Chinese standard specifies the underwater with divers about the various underwater electrical equipment, as well, although a direct relationship with the underwater operation, but may be hazardous to a variety of jobs diver underwater electrical construction, electrical safety aspects of facilities basic requirements, including the use of environmental, technical requirements, installation, and emergency measures. This standard applies to the diver diving apparatus, equipment, systems, tools, structure, facility, as well as the safe use of electricity underwater operations. |
GB 16636-2008: Code of safety for driver use of electricity underwater---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Code of safety for driveruse of electricity underwater
ICS 03.220.40; 13.100
R54
National Standards of People's Republic of China
Replacing GB 16636-1996, GB 17869-1999
Diver underwater electrical safety regulations
Posted 2008-06-19
2009-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Environment 2
5 Technical requirements 5
6 installation and operation 7
7 emergency measures 11
Appendix A (informative) human safety Current 12
Annex B (informative) underwater safety distance 14
Foreword
All the technical contents of this standard is mandatory.
This standard mainly with reference to the International Marine Contractors Association (IMCA) "underwater electrical safety code of practice" (AODC035), on
GB 16636-1996 "diver underwater electrical safety technical specifications" and GB 17869-1999 "diver underwater electrical safety rules"
Integration amendment and in accordance with GB/T 1.1-2000 requirements be modified editorial.
This standard replaces GB 16636-1996 "diver underwater electrical safety technical specifications" and GB 17869-1999 "diver underwater use
Electrical safety procedures. " This standard will be incorporated into the main content of GB 17869-1999 GB 16636-1996, and remove the two standards
Overlapping narrative text.
Appendix A of this standard and Appendix B is an informative annex.
The standard proposed by the People's Republic of China Ministry of Transportation.
This standard is under the jurisdiction of the Ministry of Communications and salvage underwater engineering Standardization Technical Committee.
This standard was drafted. Shanghai Jiaotong University Institute of Marine Sciences underwater engineering.
The main drafters. Zhang Guoguang, Dong Jianshun, Jing Yanlin, Wangbao Jian, He Xiuxia.
This standard replaces the standards previously issued as follows.
--- GB 16636-1996;
--- GB 17869-1999.
Diver underwater electrical safety regulations
1 Scope
This standard specifies the divers and underwater operations related to a variety of underwater electrical equipment, and underwater operations, although with no direct relationship, but it may
It would pose a hazard in a variety of jobs diver underwater electrical structure, facility in terms of the basic requirements for safe use of electricity, including the use of environmental, technical
Requirements, installation procedures, and emergency measures.
This standard applies to tools, equipment, systems, tools, structure, facility, as well as electrical safety-related and diver underwater diving installed.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 6722 Blasting Safety Regulations
GB/T 16560 deck decompression chamber
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
Avoid or prevent a variety of electrical devices may be provided by the use of underwater (or pressure tank) caused by divers hazards (such as. electric shock), and because
Heating cause degradation of electrical insulating materials and toxic, explosive product, or because of the heated surface, faulty equipment, switchgear and other electrical generation
Arc, spark ignited some of the damage caused to the mixed gas divers.
3.2
The entire device and the system can transport divers diving operations at desired pressure (including. deck decompression chamber, diving bell, underwater
Working spaces and personnel transport tanks, etc.) and various types of diving, as well as divers in diving operations should dress, or to maintain the harness Peigua
(Eg. wetsuit, scuba, umbilical cord and communications equipment, etc.).
3.3
One kind of transport divers in case of emergency means the pressure vessel, one of the main equipment of diving systems. Divers Emergency transport system
The system is equipped with a gas, electrical and audio-visual detection device can be in contact with their counterparts in the deck decompression chamber. Also known as. personnel transport compartment.
3.4
Tools diver when used underwater, equipment and instruments.
3.5
Large-scale installations and structures in the long-term underwater work, such as. impressed current cathodic protection systems, subsea oil and gas production systems, subsea pipelines and water
Under the cables.
3.6
Nearby underwater electrical equipment in normal use, such as. the environment in which the pressure, gas, temperature, humidity, and divers love the dress
And other conditions.
3.7
It can be allowed to flow through the body of the diver maximum current.
3.8
When the voltage gradient occurs in the water will not harm diver, divers minimum distance from a charged body.
3.9
A setting in the vicinity of the work area, used to complete the cabin structure underwater welding and other work. Under the pressure of the outside world of the sea, the work chamber
The interior has a dry and moderate gas environment.
3.10
By electrical heating mode, warm heat generation diver underwater diving suit, pants, gloves, hats, etc. are necessary.
3.11
A variety of small devices during diving operations carried by a diver, such as. cameras, underwater lighting, power hand tools and non-destructive testing
(NDT) devices.
3.12
The seabed by electric drive for a variety of work tools, equipment powered hydraulic pump or power source.
3.13
Take fully insulated, or perfectly conducting, or insulating and conducting combined and other measures to avoid the potential causes of the water caused by the potential gradient electric shock hazard
Water service.
3.14
Under water wet environmental conditions implemented by welding and cutting operations.
3.15
One kind of a pressure-regulator tanks and self-propelled submersible. After when necessary, by divers from the water into the surge tank regulator submersible,
Or go out to the water from inside the submersible. Also known as. the regulator out of submersible device (LILOS).
4 Environment
4.1 deck cabin decompression and emergency transport systems
4.1.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa, and can change at different rates.
4.1.2 Environment. 0MPa ~ 0.6MPa compressed air; or an oxygen partial pressure of not more than 0.06MPa and an oxygen concentration of not more than 23% oxygen
Mixture.
4.1.3 Temperature. saturated cabin is 25 ℃ ~ 35 ℃, cabin air is 0 ℃ ~ 50 ℃.
4.1.4 Humidity. cabin relative humidity of 50% to 75%, under special circumstances, a brief rise to 100%.
4.1.5 diver dress. wearing thin non-electrical protection clothing.
4.2 The Diving Bell and provided guillotine submersible
4.2.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa, and rapidly changing.
4.2.2 Environment. 0MPa ~ 0.6MPa compressed air; or an oxygen partial pressure of not more than 0.06MPa and an oxygen concentration of not more than 23% oxygen
Mixture.
4.2.3 Temperature. inner equipment for 25 ℃ ~ 35 ℃, special cases can be reduced to 10 ℃. External at 0 ℃ ~ 30 ℃, but is usually at 5 ℃ ~
15 ℃.
4.2.4 Humidity. high relative humidity inside the device, external exposure to seawater splash zones, and it can be submerged.
4.2.5 diver dress. wearing thin non-electrical protection clothing.
4.3 Underwater working spaces
4.3.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa.
4.3.2 Environment. 0MPa ~ 0.6MPa compressed air; or an oxygen partial pressure of not more than 0.06MPa and an oxygen concentration of not more than 23% oxygen
Mixture.
4.3.3 temperature. Internal temperature 5 ℃ ~ 40 ℃, if in a very small cabin, the temperature can rise to special circumstances 60 ℃.
4.3.4 Humidity. fully submerged in the water under the outside pressure. During operation, a relative humidity of 70% to 100%.
4.3.5 Diver Dress. Wear rubber wetsuit, conventional heat welding clothes or clothes.
4.4 Electric wetsuit
4.4.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa, does not change rapidly.
4.4.2 Environment. When the diver enters or leaves the diving bell, the environment is 0MPa ~ 0.6MPa compressed air; or an oxygen partial pressure of not more than
0.06MPa and an oxygen concentration of not more than 23% of the oxygen-containing gas mixture. In support of the water diving, the diver enters or leaves the table ocean
When the surface, atmospheric pressure environment.
4.4.3 temperature. depend on the depth of which the water temperature, usually at 5 ℃ ~ 15 ℃.
4.4.4 Humidity. the external environment is usually water.
4.4.5 Diver Dress. Wear rubber wetsuit.
4.5 manned submersible
4.5.1 pressure. internal pressure remains in the atmospheric environment, the external pressure depending on the depth of the job.
4.5.2 environment. an oxygen partial pressure of not more than 0.06MPa and an oxygen concentration of not more than 23% of the oxygen-containing gas mixture.
4.5.3 Temperature. The internal temperature of 10 ℃ ~ 25 ℃, 2 ℃ can temporarily lowered or raised to 35 ℃. The exterior is of deep seawater temperature,
That is 0 ℃ ~ 30 ℃.
4.5.4 Humidity. cabins, relative humidity is high; EVA, from the atmosphere (splash or immersion zone) to the sea.
4.5.5 Diver Dress. wear ordinary clothing or rubber diving suit.
4.6 ROV
4.6.1 Pressure. Once fully into the water, the external pressure is the pressure of the surrounding water environment. The pressure in the submersible launching or recovery
, It will quickly change.
4.6.2 Environment. the device is fully submerged in seawater.
4.6.3 Temperature. Water temperature changes from 0 ℃ ~ 30 ℃.
4.6.4 Humidity. external environment is water.
4.6.5 Diver Dress. Wear rubber wetsuit.
4.7 umbilical cord
4.7.1 pressure. pressure depends on water depth, the range 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa. Pressure change
rapid.
4.7.2 environment. air, mist or splashing water.
4.7.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, special circumstances may be less than 0 ℃ or up to 50 ℃.
4.7.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.7.5 Diver Dress. Wear rubber wetsuit.
4.8 handheld devices
4.8.1 pressure. depending on water depth pressure range 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa. Pressure change
rapid.
4.8.2 environment. air, splash or completely submerged in the sea fog, you can also enter 0.6MPa compressed air or helium pressure of 6MPa
Oxygen gas mixture environment.
4.8.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.8.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.8.5 Diver Dress. Wear rubber wetsuit.
4.9 subsea equipment
4.9.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa.
4.9.2 environment. air, mist or splashing water.
4.9.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.9.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.9.5 Diver Dress. Wear rubber wetsuit.
4.10 Wet Welding and Cutting
4.10.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa.
4.10.2 Setting. atmospheric, mist or splashing water.
4.10.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.10.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.10.5 Diver Dress. Wear rubber wetsuit or heavy diving suit, helmet wrap a thin rubber or insulating film, wear rubber gloves.
4.11 plus current device
4.11.1 Pressure. 0MPa ~ 3MPa.
4.11.2 Setting. atmospheric, mist or splashing water.
4.11.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.11.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.11.5 Diver Dress. Wear rubber wetsuit.
4.12 power equipment
4.12.1 Pressure. 0MPa ~ 3MPa.
4.12.2 Setting. atmospheric, mist or splashing water.
4.12.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.12.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.12.5 Diver Dress. Wear rubber wetsuit.
4.13 water distribution equipment
4.13.1 Pressure. atmospheric environment.
4.13.2 Setting. from dry, warm air-conditioned room conditions until the exposed deck of the ship (wind, rain, waves and vibration).
4.13.3 Temperature. depends on the temperature of their environment, usually in the 0 ℃ ~ 50 ℃.
4.13.4 Humidity. from dry atmosphere until the splash zone.
4.13.5 Diver Dress. wear ordinary clothing or rubber diving suit.
4.14 underwater explosive device
4.14.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa.
4.14.2 Setting. atmospheric, mist or splashing water.
4.14.3 Temperature. immersion in seawater at a temperature of 0 ℃ ~ 30 ℃, but is generally 5 ℃ ~ 15 ℃.
4.14.4 Humidity. from the atmosphere (splash or immersion zone) to the sea.
4.14.5 Diver Dress. Wear rubber wetsuit.
4.15 Battery
4.15.1 Pressure. atmospheric environment.
4.15.2 Setting. completely watertight.
4.15.3 Temperature. depends on the temperature of their environment, typically 0 ℃ ~ 50 ℃.
4.15.4 Humidity. dry.
4.15.5 Diver Dress. wear ordinary clothing or rubber diving suit.
4.16 Insulation Materials
4.16.1 Pressure. 0MPa ~ 6MPa, but generally 0MPa ~ 3MPa, and can change at different rates.
4.16.2 Setting. from dry, warm air-conditioned room conditions until the exposed deck of the ship (wind, rain, waves and vibration).
4.16.3 Temperature. depends on the temperature of their environment, typically 0 ℃ ~ 50 ℃.
4.16.4 Humidity. from dry atmosphere until the splash zone.
4.16.5 Diver Dress. wear ordinary clothing or rubber diving suit.
5 Technical requirements
Basic requirements 5.1 underwater electricity and water distribution equipment
Design, construction, installation and testing of electrical devices 5.1.1 underwater electrical equipment and water distribution equipment shall comply with the relevant provisions of the State.
5.1.2 AC power through isolation transformer should.
a) as from ungrounded secondary isolation transformer should be used with a circuit breaker line insulation monitor.
b) if there is secondary from ground isolation transformer should be used with a protection device automatically tripped, and reliable grounding alarm device
Home, limiting their fault current is less than 1A.
5.1.3 automatic trip device operation response time of less than 20ms, and should be able to re-adjust the diving supervision after the necessary security checks
whole. Also, these devices should be equipped with overload protection device can be re-adjusted by the diving operation supervised.
Electrical System 5.1.4 underwater equipment shall not be used for its metal shell circuit, the circuit protection device shall be provided to automatically trip
Overload and circuit protection.
Metal structural components 5.1.5 underwater equipment should be grounded, grounding resistance is not greater than 4Ω, and has sufficient mechanical strength.
5.1.6 For all power divers underwater use, you should use an isolation transformer or a separate generator.
5.2 deck cabin decompression and emergency transport systems
5.2.1 Power Voltage deck cabin decompression and emergency transport system shall comply with the requirements in Table 1.
Table 1
condition
Current human security /
mA
Impedance current path /
Voltage/
Maximum rated
AC automatic tripping device
Automatic trip device DC
No automatic tripping AC unit
DC without automatic tripping device
7.5
Voltage (V) = current safety to human body (A) × current path impedance (Ω). Wherein calculating the current human safety, see Appendix A.
5.2.2 Each insulated distribution system shall be provided with a ground breaking or leakage detection alarm device, insulation resistance value is not less than 5MΩ.
When the power supply test equipment 5.2.3 AC 220V, excitation voltage of various sensors should not exceed 10V (typical current
15mA). The instrument shall be protected associated with the sensor.
5.2.4 other relevant provisions, in accordance with GB/T 16560 of the relevant provisions.
5.3 The Diving Bell and provided guillotine submersible
5.3.1 The Diving Bell and provided guillotine submersible electric voltage, should meet the requirements of Table 1.
5.3.2 Diving bell inside the clock power for 24V DC power supply by the diving bell mounted on the outer surface of the water pressure vessel and the rectifier transformer power supply
provide.
220V AC 5.3.3 for diving bell exterior lighting shall have a current limit fault isolation transformer and residual current protection
Active Protection System device (RCD) is constituted to provide power protection.
5.4 Underwater working spaces
5.4.1 underwater work spaces voltage electricity, should meet the requirements of Table 1.
5.4.2 cabin working power (eg. preheat power and portable power tools, etc.) should be carried out on-line monitoring through wire insulation monitor.
5.4.3 tank umbilical cable insulation resistance should continuously monitor the situation through the wire insulation monitor. Wire insulation monitor can be monitored via the drain
Resistance, and provides continuous readings to monitor changes in the circuit insulation.
5.5 manned submersible
5.5.1 manned submersible electric voltage electrical equipment facility shall comply with the requirements of Table 1. The cockpit is not greater than the DC supply only
24V power for life support and control circuits.
5.5.2 Place the transformer and rectifier power supply for treatment submersible vessel loop and control equipment, should be placed outside the submersible.
5.6 ROV
5.6.1 ROV use of AC power by 380V (440V) transformer three-phase AC power supply system of the ship and through the umbilical cord electric
Cable through the isolation transformer provides.
5.6.2 ROV and diver joint operations, should take appropriate safety measures, such as. diver should wear a full wetsuit anti-power
Conduct operations.
5.7 umbilical cord
5.7.1 umbilical cable should have sufficient tensile strength, while measures should be taken so that it does not withstand tensile loads.
5.7.2 umbilical cord may be external voltage electricity diver or related personnel touch electrical equipment shall comply with the requirements given in Table 1.
5.7.3 The umbilical cable protective measures should take the initiative, and the power line access is provided on the surface of the isolation transformer.
5.8 handheld devices
5.8.1 diver portable equipment should be durable, reliable insulation.
Power Voltage 5.8.2 diver handheld devices shall comply with the requirements given in Table 1.
5.9 subsea equipment
5.9.1 High-power subsea equipment (such as. the suction dredging pump), power to the motor through the umbilical cord from the surface of 380V (440V) for three-phase AC
Electrical system, ensure insulation and a grounded shield performance of the primary umbilical cable to the motor connector.
5.9.2 Auxiliary equipment subsea operations divers should wear insulated gloves and take appropriate safety measures.
5.10 Electric wetsuit
5.10.1 wetsuit electric resistance wire should have high fatigue strength, and the structure is solid and difficult to break. And electric insulating wetsuit
Conductive fabric should be fire-retardant, high temperature, non-toxic materials.
5.10.2 electric wetsuit voltage electricity, should meet the requirements given in Table 2.
Table 2
condition
Current human security /
mA
Impedance current path /
Voltage/
Maximum rated
AC automatic tripping device
Automatic trip device DC
DC without automatic tripping device
22.8
5.10.3 diving suit helmet electric or gas heater, should be completely enclosed within a conductive shield grounded.
Before electric 5.10.4 diver wearing a diving suit diving operations, respond to an electric circuit wetsuit and rigorous visual inspection and
Electrical safety testing, safety performance test failure shall not be used.
5.11 Wet Welding and Cutting
Power Voltage 5.11.1 wet welding and cutting equipment shall comply with the provisions given in Table 3.
Table 3
condition
Current human security /
mA
Impedance current path /
Voltage/
Maximum rated
DC without automatic tripping device 407,503,024
5.11.2 electric oxygen cutting device should meet the following conditions.
a) electrical aerobic oxygen torch valve should be designed, the valve should always make sure that the cut strip insulation.
b) cut Article shall have an electrically insulating layer; the electrically insulating layer should have a high abrasion resistance, and will not long-term immersion in seawater
Which led to the deterioration of insulation properties.
5.12 plus current device
5.12.1 impressed current system should be set up isolation cover bar and/or safety signs at a distance from their proper order to avoid straying into potential diver
Regional hazards. Isolation cover bar and/or calculate the safety distance of safety signs can refer to Appendix B.
5.12.2 electric voltage impressed current devices shall comply with the requirements given in Table 3. And should take appropriate protective measures to prevent the applied electrical
Flow device system is polarized.
DC supply voltage 5.12.3 impressed current system is not more than 30V, not to set the isolation cover bar and safety signs.
Underwater divers work under 5.12.4 should be possible in the case of cutting impressed current device system power supply, or should be first detected
Electric field strength near the waters, and take appropriate protective measures can be carried out underwater operations.
5.13 power equipment
5.13.1 powered devices should be an appropriate distance from its isolation set cover bar and/or safety signs to avoid straying into potentially dangerous diver
Damage area. Isolation cover bar and/or calculate the safety distance of safety signs can refer to Appendix B.
5.13.2 Before diving operations begin to deal with power supply equipment to conduct a detailed inquiry, investigation and assessment of possible hazards,
And propose necessary security measures.
5.13.3 In existing power supply of high-power devices can not be interrupted job situation, deal with job divers take the necessary protection against electric shock
Protection, to protect the safety of diving operations.
6 Installation and Operation
6.1 underwater electricity installation requirements
6.1.1 concerning engage diver underwater diving equipment, electrical systems, tools and facilities of underwater structures facilities installation, renovation and maintenance
Repair personnel, should be proficient in electrical operating procedures, familiar with danger and problems of underwater engineering practice of holding national accreditation certificates and familiar country
Professionals and family with the relevant provisions of the standards for content.
Before installing and underwater divers about a variety of electrical facilities, equipment, or temporary electrical equipment 6.1.2, you should first check, make sure
These electrical facilities, installations or equipment has reached the current relevant state regulations and requirements of this standard.
6.1.3 Installation and diver underwater operations related to a variety of diving equipment, systems, tools, underwater structures and facilities of electrical facilities should follow
The following points.
a) all greater than 6V electrical circuit should have the appropriate fuse/circuit breaker for the short circuit protection;
b) through the electrical wires should have a full load current, overload current and fault current protection device may adopt internal action time
Sufficient cross-sectional area;
c) electrical circuit connector should be reliable, and try to reduce their number; should complete the electrical connection terminal structure, and having a length
Wire pigtail;
d) wire routing should avoid prone to mechanical damage and place to be fixed, if necessary, be some form of mechanical protection;
e) electrical circuit wiring should be separated to avoid cross-circuit or damage caused by a short circuit;
Terminal box f) electrical lines should be sealed to prevent moisture intrusion;
g) shall not use the shared fee...
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 16636-2008_English be delivered?Answer: Upon your order, we will start to translate GB 16636-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 16636-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB 16636-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 16636-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 16636-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|