HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (17 Jan 2026)
Path: Home > GB > Page157 > GB 1588-2024                   Home > Standard_List > GB > Page157 > GB 1588-2024

GB 1588-2024 English PDF

US$359.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 1588-2024: Medical glass thermometer
Status: Valid

GB 1588: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB 1588-2024English359 Add to Cart 4 days [Need to translate] Medical glass thermometer Valid GB 1588-2024
GB 1588-2001English339 Add to Cart 3 days [Need to translate] Clinical thermometer Valid GB 1588-2001
GB 1588-1989English399 Add to Cart 3 days [Need to translate] Clinical thermometer Obsolete GB 1588-1989

PDF similar to GB 1588-2024


Standard similar to GB 1588-2024

GB 9706.227   GB 24627   YY/T 1519   GB/T 21416   GB/T 21417.1   

Basic data

Standard ID GB 1588-2024 (GB1588-2024)
Description (Translated English) Medical glass thermometer
Sector / Industry National Standard
Classification of Chinese Standard C38
Classification of International Standard 11.040.55
Word Count Estimation 18,111
Date of Issue 2024-04-29
Date of Implementation 2026-05-01
Older Standard (superseded by this standard) GB 1588-2001
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB 1588-2024: Medical glass thermometer

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11:040:55 CCSC38 National Standards of People's Republic of China Replaces GB 1588-2001 Medical glass thermometer Released on 2024-04-29 2026-05-01 implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Requirements 1 5 Test methods 6 6 Cycle Inspection 8 7 Markings, Instructions for Use 9

Foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting: This document replaces GB 1588-2001 "Glass Thermometers": Compared with GB 1588-2001, except for structural adjustments and editorial changes, In addition, the main technical changes are as follows: --- Changed the scope of application of the standard (see Chapter 1, Chapter 1 of the:2001 edition); --- Deleted the contents of anus (veterinary) and neonatal rod type, and adjusted the requirements for measurement sites (see 4:1:1, 3:1 of the:2001 edition); --- Changed the requirements for basic dimensions (see 4:1:2, 4:1 of the:2001 edition); --- Changed the stress requirements (see 4:2:8, 4:10 of the:2001 edition); --- Unified the requirements for the width of the glaze band of glass tubes (see 4:2:9, 4:2:4 of the:2001 edition); --- Changed the requirements for scale plates (see 4:4, 4:7 of the:2001 edition); --- Changed the requirements for the width of the scale lines of the rod-type glass thermometer (see 4:6:2, 4:9:2 of the:2001 edition); --- The test method for bubbles has been changed (see 5:3, 5:5:2 of the:2001 edition); --- Changed the test method for the difficulty of temperature-sensitive liquid column to be thrown off (see 5:4:4, 5:14 of the:2001 edition); --- Deleted the content of batch inspection (see 6:2 of the:2001 edition); --- Changed the sampling plan for periodic inspection of indications (see 6:3, 6:3:3 of the:2001 edition); --- Deleted the contents of packaging, transportation and storage (see Chapter 8 of the:2001 edition); --- Deleted the content of quality assurance (see Chapter 9 of the:2001 edition): Please note that some of the contents of this document may involve patents: The issuing organization of this document does not assume the responsibility for identifying patents: This document is proposed and coordinated by the State Food and Drug Administration: The previous versions of this document and the documents it replaces are as follows: ---First issued as GB 1588-1979 in 1979, first revised in 1989, second revised in:2001; ---This is the third revision: Medical glass thermometer

1 Scope

This document specifies the requirements, inspection rules, marking, instructions for use of medical glass thermometers and describes the corresponding test methods: This document is applicable to medical glass thermometers (hereinafter referred to as "glass thermometers") for measuring human body temperature, with a temperature measurement point structure and a temperature sensing medium of liquid: It is called a glass thermometer):

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document: For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document: GB/T 2829 Periodic inspection sampling procedures and tables (applicable to the inspection of process stability)

3 Terms and definitions

The following terms and definitions apply to this document: 3:1 scaleline Lines engraved on a glass rod or scale to indicate temperature values: Note: Also called scale line: 3:2 Scale plate Internal standard glass thermometer is a straight, colored (such as milky white) sheet with scale lines, scale values and other symbols printed inside: Note: Also called scale plate: 3:3 The phenomenon that the temperature-sensing liquid column of a glass thermometer automatically retreats toward the temperature-sensing bulb above the retention point structure: Note: It indicates the stability of the indication of glass thermometer within a certain period of time: 3:4 The phenomenon that the temperature-sensing liquid column of a glass thermometer is difficult to retract under a certain external force: 3:5 Interrupt liquid column The liquid column of the glass thermometer is disconnected above the retention point structure:

4 Requirements

4:1 Type 4:1:1 The type and measuring range of glass thermometers shall comply with the requirements of Table 1:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 1588-2024_English be delivered?

Answer: Upon your order, we will start to translate GB 1588-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 1588-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB 1588-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB 1588-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 1588-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information