|
US$359.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB 1588-2024: Medical glass thermometer Status: Valid GB 1588: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB 1588-2024 | English | 359 |
Add to Cart
|
4 days [Need to translate]
|
Medical glass thermometer
| Valid |
GB 1588-2024
|
| GB 1588-2001 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Clinical thermometer
| Valid |
GB 1588-2001
|
| GB 1588-1989 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Clinical thermometer
| Obsolete |
GB 1588-1989
|
PDF similar to GB 1588-2024
Basic data | Standard ID | GB 1588-2024 (GB1588-2024) | | Description (Translated English) | Medical glass thermometer | | Sector / Industry | National Standard | | Classification of Chinese Standard | C38 | | Classification of International Standard | 11.040.55 | | Word Count Estimation | 18,155 | | Date of Issue | 2024-04-29 | | Date of Implementation | 2026-05-01 | | Older Standard (superseded by this standard) | GB 1588-2001 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB 1588-2024: Medical glass thermometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11:040:55
CCSC38
National Standards of People's Republic of China
Replaces GB 1588-2001
Medical glass thermometer
Released on 2024-04-29
2026-05-01 implementation
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Requirements 1
5 Test methods 6
6 Cycle Inspection 8
7 Markings, Instructions for Use 9
Foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents"
Drafting:
This document replaces GB 1588-2001 "Glass Thermometers": Compared with GB 1588-2001, except for structural adjustments and editorial changes,
In addition, the main technical changes are as follows:
--- Changed the scope of application of the standard (see Chapter 1, Chapter 1 of the:2001 edition);
--- Deleted the contents of anus (veterinary) and neonatal rod type, and adjusted the requirements for measurement sites (see 4:1:1, 3:1 of the:2001 edition);
--- Changed the requirements for basic dimensions (see 4:1:2, 4:1 of the:2001 edition);
--- Changed the stress requirements (see 4:2:8, 4:10 of the:2001 edition);
--- Unified the requirements for the width of the glaze band of glass tubes (see 4:2:9, 4:2:4 of the:2001 edition);
--- Changed the requirements for scale plates (see 4:4, 4:7 of the:2001 edition);
--- Changed the requirements for the width of the scale lines of the rod-type glass thermometer (see 4:6:2, 4:9:2 of the:2001 edition);
--- The test method for bubbles has been changed (see 5:3, 5:5:2 of the:2001 edition);
--- Changed the test method for the difficulty of temperature-sensitive liquid column to be thrown off (see 5:4:4, 5:14 of the:2001 edition);
--- Deleted the content of batch inspection (see 6:2 of the:2001 edition);
--- Changed the sampling plan for periodic inspection of indications (see 6:3, 6:3:3 of the:2001 edition);
--- Deleted the contents of packaging, transportation and storage (see Chapter 8 of the:2001 edition);
--- Deleted the content of quality assurance (see Chapter 9 of the:2001 edition):
Please note that some of the contents of this document may involve patents: The issuing organization of this document does not assume the responsibility for identifying patents:
This document is proposed and coordinated by the State Food and Drug Administration:
The previous versions of this document and the documents it replaces are as follows:
---First issued as GB 1588-1979 in 1979, first revised in 1989, second revised in:2001;
---This is the third revision:
Medical glass thermometer
1 Scope
This document specifies the requirements, inspection rules, marking, instructions for use of medical glass thermometers and describes the corresponding test methods:
This document is applicable to medical glass thermometers (hereinafter referred to as "glass thermometers") for measuring human body temperature, with a temperature measurement point structure and a temperature sensing medium of liquid:
It is called a glass thermometer):
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document:
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document:
GB/T 2829 Periodic inspection sampling procedures and tables (applicable to the inspection of process stability)
3 Terms and definitions
The following terms and definitions apply to this document:
3:1
scaleline
Lines engraved on a glass rod or scale to indicate temperature values:
Note: Also called scale line:
3:2
Scale plate
Internal standard glass thermometer is a straight, colored (such as milky white) sheet with scale lines, scale values and other symbols printed inside:
Note: Also called scale plate:
3:3
The phenomenon that the temperature-sensing liquid column of a glass thermometer automatically retreats toward the temperature-sensing bulb above the retention point structure:
Note: It indicates the stability of the indication of glass thermometer within a certain period of time:
3:4
The phenomenon that the temperature-sensing liquid column of a glass thermometer is difficult to retract under a certain external force:
3:5
Interrupt liquid column
The liquid column of the glass thermometer is disconnected above the retention point structure:
4 Requirements
4:1 Type
4:1:1 The type and measuring range of glass thermometers shall comply with the requirements of Table 1:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB 1588-2024_English be delivered?Answer: Upon your order, we will start to translate GB 1588-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB 1588-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB 1588-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB 1588-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 1588-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|