GA/T 110-2013English279 Add to Cart Days<=3 General requirements for fire protection materials of structural elements GA/T 110-2013

   

BASIC DATA
Standard ID GA/T 110-2013 (GA/T110-2013)
Description (Translated English) General requirements for fire protection materials of structural elements
Sector / Industry Public Security (Police) Industry Standard (Recommended)
Classification of Chinese Standard C84
Classification of International Standard 13.220.50
Word Count Estimation 11,164
Older Standard (superseded by this standard) GA 110-1995
Quoted Standard GB 8624; GB/T 9969; GB/T 9978.1-2008; GB 14907-2002; GB/T 20285-2006; GA 98-2005; JC/T 626; CECS 24-1990
Drafting Organization Ministry of Public Security, Sichuan Fire Research Institute
Administrative Organization Standardization Technical Committee of the National Fire Safety Sub - Technical Committee
Regulation (derived from) Building components with the general requirements of fire protection materials, the industry standard revised release; industry standard filing notice 2014 No. 4 (total 172)
Proposing organization Ministry of Public Security Fire Department
Issuing agency(ies) Ministry of Public Security of the People Republic of China
Summary This standard specifies the terms and definitions, classification, requirements, test methods, inspection rules and marking, packaging, transportation and storage of fire protection materials for building components. This standard applies to all types of

GA/T 110-2013
General requirements for fire protection materials of structural elements
ICS 13.220.50
C84
People's Republic of China Public Security Industry Standards
Replacing GA 110-1995
Building components with fire protection materials General requirements
Issued on. 2013-03-11
2013-04-01 implementation
People's Republic of China Ministry of Public Security
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GA 110-1995 "building components fire spraying material performance test method."
This standard GA 110-1995 compared to major changes are as follows.
--- Modify the scope (see Chapter 1, Section 11995 edition);
--- Modify the terms and definitions (see Chapter 3, Section 31995 edition);
--- Increasing the classification (see Chapter 4);
--- Modified specimen preparation (see Chapter 4 6.1,1995 version);
--- Modify the water resistance requirements and test methods (see 5.2,6.1,1995 version 5.14);
--- Increase the circulation of the requirements and test methods for resistance to thermal (see 5.3,6.2);
--- Test method by deleting a state in the container, low-temperature storage stability, thermal storage stability, dry density, compressive strength, thermal conductivity
The rate of initial drying crack resistance, surface drying time, appearance and color, bond strength, bending resistance, vibration resistance, resistance to freeze-thaw cycles
Resistance, salt water, acid and alkali resistance, heat resistance, corrosion of the steel substrate (see the 1995 version of the 5.1 ~ 5.13,
From 5.15 to 5.19);
--- Modify the fire resistance test method (see 6.5,1995 version 5.20.3).
This standard was proposed by the Ministry of Public Security Fire Department.
This standard by the National Standardization Technical Committee for fire protection material Technical Committee (SAC/TC113/SC7) centralized.
This standard was drafted. Ministry of Public Security of Sichuan Fire Research Institute.
The main drafters. Zhang Cai, Cheng Daobin, Nie Tao, Ma Yu, Meng Zhi, Zhou Xiaoyong, Zhang Bin.
This standard replaces the standards previously issued as follows.
--- GA 110-1995.
Building components with fire protection materials General requirements
1 Scope
This standard specifies the terms and definitions of building components fire protection materials, classification, requirements, test methods, inspection rules and signs, including
Equipment, transportation and storage.
This standard applies to fire protection materials other than wood structure of various types of building elements, does not apply to finishing fire retardant paints.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 8624 Classification for burning behavior of building materials and products
GB/T 9969 General Instructions industrial products
GB/T 9978.1-2008 building components resistance test methods - Part 1. General requirements
GB 14907-2002 fireproof coatings
GB/T 20285-2006 material of smoke toxicity hazard rating
GA 98-2005 concrete structure fire retardant coating
JC/T 626 fiber reinforced concrete building tablet low alkalinity
CECS24-1990 fireproof paint application of technical specifications
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Building components with fire protection material fireprotectionmaterialofstructuralelement
Covered or coated on the surface of building elements, can improve the fire resistance of a building element, while meeting the appropriate physical and chemical properties and combustion properties
Smoke toxicity requested material.
Category 4
By material types into building components with fire protection material (hereinafter referred to as the protective material) coating and other classes.
a) coating categories. including intumescent or intumescent coating, spray fiber materials, building components can be coated on the surface;
b) Other categories include. inorganic (fiber) plates, coils, mineral wool and other materials may be covered or coated on the surface of building components.
5 Requirements
5.1 General
Performance protective material should be able to meet the requirements of 5.2 to 5.6, and should be qualified by the production plant quality inspection department.