US$599.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GA 98-2005: Fire resistive coating for concrete structure Status: Obsolete GA 98: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GA 98-2005 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Fire resistive coating for concrete structure
| Obsolete |
GA 98-2005
|
GA 98-1995 | English | 479 |
Add to Cart
|
3 days [Need to translate]
|
(General specification for fireproof coating of prestressed concrete floor)
| Obsolete |
GA 98-1995
|
PDF similar to GA 98-2005
Standard similar to GA 98-2005 GB 4351 GA 602 GB 4066.2 GA 999
Basic data Standard ID | GA 98-2005 (GA98-2005) | Description (Translated English) | Fire resistive coating for concrete structure | Sector / Industry | Public Security (Police) Industry Standard | Classification of Chinese Standard | C84 | Classification of International Standard | 13.220.20 | Word Count Estimation | 15,151 | Date of Issue | 2005-12-08 | Date of Implementation | 2006-03-01 | Older Standard (superseded by this standard) | GA 98-1995 | Quoted Standard | GBJ 107; GB/T 1728-1989; GB/T 1733-1993; GB 3186-1982; GB/T 9265-1988; GB/T 9978; GB 14907-2002; JC/T 626; JG/T 24-2000 | Adopted Standard | BS EN 1363-2-1999, MOD; GT 98063-1998, MOD | Regulation (derived from) | Announcement of the Ministry of Public Security on Abolishing 440 Standards of Public Security Industry | Issuing agency(ies) | Ministry of Public Security of the People Republic of China | Summary | This standard specifies the definition and classification, requirements, test methods, inspection rules and signs, packaging, transportation and storage of fireproofing coatings for concrete structures. This standard applies to industrial and civil buildings and roads, railways (including subway) tunnel concrete surface of the fire retardant coating. |
GA 98-2005: Fire resistive coating for concrete structure---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fire resistive coating for concrete structure
ICS 13.220.20
C84
People's Republic of China Public Safety Industry Standard
Replacing GA 98-1995
Concrete structure fireproof coating
Released on December 12,.2008
2006-03-01 implementation
Ministry of Public Security
Content
Foreword III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Classification and Marking 1
5 Requirements 2
6 Test method 3
7 Inspection rules 9
8 Marking, packaging, transportation and storage 10
Appendix A (Normative) Test Methods for Dimensions and Coating Thickness of Fire Tests for Concrete Members
Reference 12
Foreword
Chapters 5, 6, and 7 of this standard are mandatory, and the rest are recommended.
This standard replaces GA 98-1995 "General Technical Conditions for Prestressed Concrete Floor Fireproof Coatings" from the date of implementation.
The main difference between this standard and GA 98-1995 is that the thermal conductivity requirements are eliminated; the performance requirements of tunnel fire retardant coatings are increased.
experiment method. The test modification for the fire resistance of tunnel fire retardant coatings was carried out using BSEN1363-2.1999 Fireresistance
tests-Part 2. Alternativeandadditionalprocedures "Fire Test Part 2. Optional Programs and Additional Programs" and
GT-9806398-CVB-R1161FIREPROTECTIONFORTUNNELSPart 1. firetestprocedureforimmer-
Sedtunnels "Tunnel Fire Protection Part I. Fire Test Procedure for Buried Tunnels" was formulated.
Appendix A of this standard is a normative appendix.
This standard was proposed by the Fire Department of the Ministry of Public Security.
This standard is under the jurisdiction of the 7th Technical Committee of the National Fire Protection Standardization Technical Committee.
This standard is drafted by. Sichuan Fire Research Institute of the Ministry of Public Security.
Participated in the drafting of this standard. Sichuan Tianfu Fireproof Materials Co., Ltd., Chengdu Dadi Geotechnical Engineering Development Company.
The main drafters of this standard. Nie Tao, Sun Yuhu, Wang Liangwei, Yan Wenqing, Liu Lin, Yuan Yali, Zhang Qingming, Wu Xiaoling.
Concrete structure fireproof coating
1 Scope
This standard specifies the definition and classification of concrete structure fireproof coatings, requirements, test methods, inspection rules and signs, packaging, transportation,
Storage.
This standard applies to fireproof coatings on concrete surfaces such as industrial and civil buildings and roads, railways (including subway) tunnels.
2 Normative references
The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all
Modifications (not including errata content) or revisions are not applicable to this standard, however, parties to agreements based on this standard are encouraged to study
Whether to use the latest version of these files. For undated references, the latest edition applies to this standard.
GB J107 concrete strength inspection and evaluation standard
GB/T 1728-1989 Determination of drying time of paint film and putty film
GB/T 1733-1993 Determination of water resistance of paint film
GB 3186-1982 Sampling of coating products (neq ISO 1512.1974)
GB/T 9265-1988 Determination of alkali resistance of architectural coatings
GB/T 9978 building component fire test method
GB 14907-2002 steel structure fireproof coating
JC/T 626 fiber reinforced low alkali cement construction slab
JG/T 24-2000 synthetic resin emulsion sand wall architectural coating
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1
Coated in industrial and civil buildings and on concrete surfaces such as roads and railway tunnels, it can form a fire-resistant thermal insulation layer to improve its structure.
Fire resistant coating with fire endurance.
4 Classification and marking
4.1 Classification
4.1.1 Concrete structure fireproof coating is divided according to the place of use
a) Fire protection coating for concrete components. used for the surface of concrete structural members in buildings.
b) Tunnel fireproof coating. used for the surface of concrete structures of highways and railway tunnels, characterized by non-expanding type.
4.1.2 Fireproof coatings for concrete members are classified according to their characteristics
a) Intumescent type. The coating expands and foams at high temperature to form a fire-resistant and heat-insulating protective layer.
b) Non-expanded type. The coating density is small, and it is fire-resistant and insulated at high temperature.
4.2 Marking
The abbreviation of Chinese Pinyin letters is used as the code name, H stands for fireproof coating, P and F represent expansion type and non-expansion type, respectively, SH stands for
The relationship between tunnel fireproof coatings, various types of concrete structure fireproof coatings and code names is as follows.
Intumescent concrete component fireproof coating PH
Non-expanded concrete component fire retardant coating FH
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GA 98-2005_English be delivered?Answer: Upon your order, we will start to translate GA 98-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GA 98-2005_English with my colleagues?Answer: Yes. The purchased PDF of GA 98-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GA 98-2005?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GA 98-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|