HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GA 835-2009 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 835-2009English1599 Add to Cart 6 days [Need to translate] Oil evacuation and nitrogen injection extinguishing equipment for oil-immersed power transformer Obsolete GA 835-2009

PDF similar to GA 835-2009


Standard similar to GA 835-2009

GB 4351   GA 602   GB 4066.2   GA 999   

Basic data

Standard ID GA 835-2009 (GA835-2009)
Description (Translated English) Oil evacuation and nitrogen injection extinguishing equipment for oil-immersed power transformer
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C84
Classification of International Standard 13.220.10
Word Count Estimation 40,484
Date of Issue 2009-06-04
Date of Implementation 2009-07-01
Quoted Standard GB/T 1226; GB 5099; GB/T 8979; GB 9969.1; GB 18428; GA 61-2002; JB/T 9773
Regulation (derived from) National Engineering Standards Information Network June 22, 2009 News; industry standard filing notice 2010 No. 2 (total No. 122)
Issuing agency(ies) Ministry of Public Security
Summary This standard prescribes the requirements of the oil-immersed transformer oil-filled nitrogen injection type fire extinguishing device (hereinafter referred to as "device") and the nitrogen gas bottle group, the nitrogen release valve, the oil discharge valve, the stop valve, the decompression device, the fire control cabinet, the fire detection device, Oil and gas isolation devices and other components of the performance requirements, test methods, inspection rules, the use of manual requirements. This standard applies to the oil-filled transformer nitrogen injection extinguishing device. Protection of oil-immersed reactors and other equipment, oil and nitrogen injection fire extinguishing device can refer to the use.

GA 835-2009: Oil evacuation and nitrogen injection extinguishing equipment for oil-immersed power transformer


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Oil evacuation and nitrogen injection extinguishing equipment for oil-immersed power transformer ICS 13.220.10 C84 People's Republic of China Public Security Industry Standards Immersed transformer oil discharge nitrogen injection fire extinguishing devices Posted 2009-06-04 2009-07-01 implementation People's Republic of China Ministry of Public Security

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 model preparation 2 5 requires 3 5.1 Work environment requirements 3 5.2 means 3 5.3 Fire cabinet 3 5.4 stop valves 8 5.5 Fire control cabinet 9 5.6 Fire detection means 10 6 Test methods 10 6.1 Visual inspection 10 6.2 hydraulic strength test 10 6.3 Seal test 10 6.4 Test overpressure 11 6.5 reliability test 11 6.6 salt spray corrosion test 12 6.7 Vibration Test 12 6.8 Temperature cycling test leak 13 6.9 Test operation safety relief device 13 6.10 Manual operation test 13 Voltage resistance test 13 6.11 6.12 Insulation resistance test 13 6.13 Surge Performance Test 13 6.14 Flow Performance Test 13 6.15 decompression performance 14 6.16 mechanical exhaust assembly 14 to close the pressure test 6.17 Oil isolation device operating pressure test 14 Resistance 6.18 25 14 # transformer oil performance test 6.19 cutoff valve operation flow test 14 6.20 hot air aging test of 14 6.21 control, alarm function tests 15 6.22 high and low temperature test 15 6.23 Damp Heat Test 15 6.24 Performance test flow regulator 15 6.25 Fire detection devices operating temperature test 15 Thermal stability test fire detection device 15 6.26 Automatic fire simulation test 15 6.27 6.28 Manual fire simulation test 15 6.29 Fire Performance Test 15 7 Inspection rules 16 8 manuals - requirements 19 Appendix A (normative) Test procedures and sampling device number 20 Appendix B (normative) Cabinets, fire test procedures and the number of samples 21 Annex C (normative) nitrogen cylinders test procedures and the number of samples 22 Annex D (normative) nitrogen release valve test procedures and the number of samples 23 Appendix E (normative) Sampling procedures and test drive the number 24 Annex F (normative) Test procedures and sampling valve number 25 Annex G (normative) pressure plate test procedures and the number of samples 26 Annex H (normative) flow control valve test procedures and the number of samples 27 Annex I (normative) mechanical exhaust components of the test procedures and the number of samples 28 Appendix J (normative) electromagnetic (electric) exhaust components of the test procedures and the number of samples 29 Annex K (normative) oil and gas isolation device test program and the number of samples 30 Annex L (normative) Test valve repair procedures and sampling number 31 Annex M (normative) drain valve test procedures and the number of samples 32 Annex N (normative) connecting tube test procedures and the number of samples 33 Appendix O (normative) shut-off valve test procedures and the number of samples 34 Appendix P (normative) fire control cabinet test procedures and the number of samples 35 Appendix Q (normative) fire detection test procedures and the number of samples 36

Foreword

The standard Chapter 4, Chapter 5 and Chapter 7 are mandatory content, the rest are recommended. This standard Appendices A to Q are normative appendix. The standard proposed by the People's Republic of China Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee on Fire II Technical Committee (SAC/TC113/SC2) centralized. This standard is drafted by. Ministry of Public Security in Tianjin Fire Research Institute. It participated in the drafting of this standard. State Power Corporation of Northeast Electric Power Design Institute, Changzhou Suyuan Huadian Power Equipment Co., Ltd., Baoding Tianwei Zhuo Electrical Equipment Technology Co., Ltd. Shenzhen Huadian Power Fire. The main drafters of this standard. ROADS, Tian Liang, Liu Lianxi, Li Xi Min, high Hun Sen, Sheng Yanfeng, Yang Guofu, Wu Jianxin, Fan will, Chen. Immersed transformer oil discharge nitrogen injection fire extinguishing devices

1 Scope

This standard specifies immersed transformer oil discharge nitrogen injection fire extinguishing apparatus (hereinafter referred to as a "means") and nitrogen cylinders, nitrogen release valve, drain Valves, shut-off valve, pressure performance requirements means, fire control cabinet, fire detection equipment, oil and gas isolation devices and other components, test methods, inspection regulations Then, using the manual preparation of requirements. This standard applies to oil immersed transformer oil discharge nitrogen injection extinguishing apparatus. Extinguishing oil discharge nitrogen injection device protection oil reactors and other equipment may refer to adoption.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 1226 General Pressure Gauge GB 5099 seamless steel gas cylinders GB/T 8979 nitrogen GB 9969.1 Instructions General Industrial Products GB 18428 automatic fire extinguishing system with glass balls GA 61-2002 fixed fire extinguishing system drive, control devices General JB/T 9773 electrical contacts

3 Terms and Definitions

The following terms and definitions apply to this standard. 3.1 Transformer fire with automatic detection, automatic (or manual) start, the control valve to open the oil discharge drain relief, while the cut-off valve can be effectively hindered Conservator to stop the oil tank and control nitrogen release valve is opened to inject nitrogen inside the transformer fire-fighting equipment. Devices are typically controlled by the fire System cabinets, fire cabinets, shut-off valves, fire detection and oil discharge nitrogen injection pipe components. 3.2 Gas relay can receive the signal, fire detection devices, fire control cabinet components corresponding actions, like displaying various fire extinguishing equipment State and can alert the electrical cabinet. 3.3 And controlling nitrogen release nitrogen storage, discharge actuator oil pressure relief. Generally it is having nitrogen storage, nitrogen pressure, nitrogen release, flow Control, isolation and gas, oil discharge function components. 3.4 After receiving the start signal fire control cabinet operation and can release nitrogen valve.