Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GA 821-2009 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Water crane of fire
| Obsolete |
GA 821-2009
|
PDF similar to GA 821-2009
Standard similar to GA 821-2009 GB 4351 GA 602 GB 4066.2 GA 999
Basic data Standard ID | GA 821-2009 (GA821-2009) | Description (Translated English) | Water crane of fire | Sector / Industry | Public Security (Police) Industry Standard | Classification of Chinese Standard | C84 | Classification of International Standard | 13.220.10 | Word Count Estimation | 10,168 | Date of Issue | 2009-02-27 | Date of Implementation | 2009-06-01 | Quoted Standard | GB/T 228; GB/T 1176; GB 4452; GB 5135.6; GB/T 7307; GB/T 9439; GB 12514.1; GA 113 | Regulation (derived from) | National Engineering Standards Information Network March 16, 2009 News; industry standard filing notice 2010 No. 2 (total 122) | Issuing agency(ies) | Ministry of Public Security | Summary | This standard specifies the terms and definitions, classification and specifications, type compilation, requirements, test methods, inspection rules, requirements for the preparation of the instructions for use and marking, packaging, transportation, storage and so on. This standard applies to fire water cranes. |
GA 821-2009: Water crane of fire---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Water crane of fire
ICS 13.220.10
C84
People's Republic of China Public Security Industry Standards
Fire water crane
Posted 2009-02-27
2009-06-01 implementation
People's Republic of China Ministry of Public Security
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Classification and specifications 1
5 2 model designation
6 requires 2
7 Test Method 3
8 Inspection Rule 4
9 manuals - Requirements 5
10 signs, packaging, transportation and storage 5
Foreword
The standard Chapter 4, Chapter 5, Chapter 6 content mandatory, the rest are recommended.
The standard proposed by the People's Republic of China Ministry of Public Security Fire Department.
This standard by the National Standardization Technical Committee on Fire II Technical Committee (SAC/TC113/SC2) centralized.
This standard is drafted by. Ministry of Public Security in Tianjin Fire Research Institute.
Participated in the drafting of this standard. Heilongjiang Province Public Security Fire Department, Harbin Pipes Factory.
The main drafters of this standard. Zhao Yongshun, SUN Jia-Bin Chen Xing, Wangshu Yan, Luo Zongjun high Hun Sen, Song Yang, Secretary Chun Kui.
This standard is the first release.
Fire water crane
1 Scope
This standard specifies the terms and definitions fire water crane, classification and specifications, model designation, requirements, test methods, inspection rules, instructions for use
Book written requirements and signs, packaging, transportation, storage and so on.
This standard applies to fire water crane.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 228 metal materials at room temperature tensile test method (GB/T 228-2002, eqv ISO 6892.1998)
GB/T 1176 Cast Copper Alloys conditions (GB/T 1176-1987, neq ISO 1338. 1977)
GB 4452 outdoor fire hydrant General technical conditions
GB 5135.6 Automatic sprinkler systems - Part 6. General Valve
GB/T 7307 55o non-sealing pipe thread (GB/T 7307-2001, eqv ISO 228-1.1994)
GB/T 9439 Gray Iron Castings
GB 12514.1 fire interface - Part 1. General technical conditions for fire interface
GA 113 hydrant wrench
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
Urban water supply system for fire water facilities, the underground part (master valve, water discharge means over, open and close linkage) and shoot
Min (water diversion pipeline and jacket, fire hose interfaces, rotating mechanism, retractable mechanism, etc.) with a swingable, scalable, antifreeze, hoist
Fast, etc., are used for rapid fire, Sheung Shui.
4 Classification and specifications
4.1 Classification
4.1.1 fire water crane press inlet connection can be divided into.
a) socket formula (C);
b) flange (F).
4.1.2 fire water crane by adjusting the outlet pipe can be divided into.
a) straight-through (Z);
b) retractable (S).
4.2 Specifications
Intake into nominal diameter 100mm, 150mm, 200mm three.
Fire interface is divided into 65mm, 80mm two kinds.
Nominal divided 1.0MPa, 1.6MPa two kinds.
|