HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GA 632-2006 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 632-2006English599 Add to Cart 4 days [Need to translate] Self-contained positive pressure oxygen breathing apparatus for fire fighting Obsolete GA 632-2006

PDF similar to GA 632-2006


Standard similar to GA 632-2006

GB 4351   GA 602   GB 4066.2   GA 999   

Basic data

Standard ID GA 632-2006 (GA632-2006)
Description (Translated English) Self-contained positive pressure oxygen breathing apparatus for fire fighting
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C84
Classification of International Standard 13.220.10
Word Count Estimation 15,133
Date of Issue 2006-08-29
Date of Implementation 2007-01-01
Quoted Standard GB/T 1226-2001; GB/T 2891-1995; GB 3836.1-2000; GB 3836.4-2000; GA 124-2004; MT 867-2000
Adopted Standard EN 145-1997, NEQ
Regulation (derived from) Ministry of Public Security approved the release of seven public safety industry standards
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the type, technical requirements, test methods, inspection rules, marking, packaging, storage and other requirements of the positive pressure fire breathing oxygen respirator. This standard applies to firefighters and emergency rescue workers in toxic, hypoxia, smoke, suspended in the air of harmful pollutants and other harsh environments, emergency relief or disaster relief work in the use of positive pressure fire breathing apparatus (the following Referred to as breathing apparatus). This standard does not apply to positive pressure fire breathing apparatus, diving respirators and negative pressure breathing apparatus.

GA 632-2006: Self-contained positive pressure oxygen breathing apparatus for fire fighting

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Self-contained positive pressure oxygen breathing apparatus for fire fighting ICS 13.220.10 C84 People's Republic of China Public Safety Industry Standard Positive pressure fire oxygen breathing apparatus Released on.2006-08-29 2007-01-01 implementation Ministry of Public Security

Content

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 type, classification, model 2 4.1 Type 2 4.2 Classification 2 4.3 Model 2 5 Technical requirements 2 5.1 Appearance quality 2 5.2 Structural requirements 2 5.3 Material Requirements 3 5.4 Wearing quality 3 5.5 Air tightness 3 5.6 Protective performance 3 5.7 Oxygen supply performance 4 5.8 Automatic replenishment valve opening pressure 4 5.9 Exhaust valve opening pressure 4 5.10 Positive pressure performance 4 5.11 Temperature resistance 4 5.12 Pressure gauge 4 5.13 Mask Performance 4 5.14 Effective volume of the airbag or breathing chamber 5 5.15 breathing hose 5 5.16 Pressure alarm 5 5.17 Exhalation valve and inhalation valve 5 5.18 Pressure reducer safety valve 5 5.19 High-voltage component strength 5 5.20 Personnel wearing performance 5 6 Test method 5 6.1 Appearance quality, signs, packaging inspection 5 6.2 Structural inspection 5 6.3 Surface resistance measurement 5 6.4 Flame retardant test of materials 5 6.5 Wearing quality measurement 6 6.6 Air tightness test 6 6.7 Protective performance test 6 6.8 Determination of oxygen supply performance 6 6.9 Automatic replenishment valve opening pressure measurement 7 6.10 Exhaust valve opening pressure measurement 7 6.11 Positive pressure performance test 7 6.12 Temperature resistance test 7 6.13 Pressure gauge test 7 6.14 Field of view test 7 6.15 Determination of the effective volume of the airbag or breathing chamber 7 6.16 Breathing hose performance test 7 6.17 Pressure alarm test 8 6.18 Exhalation valve and suction valve performance test 8 6.19 Pressure reducer safety valve performance test 8 6.20 High-voltage component strength test 9 6.21 Personnel wearing performance test 9 7 Inspection rules 9 7.1 Inspection classification 9 7.2 Type inspection 9 7.3 Factory inspection 10 8 Marking, packaging and storage 11 8.1 Mark 11 8.2 Packing 11 8.3 Storage 11

Foreword

5.2, 5.3, 5.5, 5.6, 5.7, 5.10, 5.17, 5.19 of this standard are mandatory provisions, and the rest are recommended provisions. This standard and the European Committee for Standardization CEN approved EN145-1997 "respiratory protector self-contained compressed oxygen or compressed oxygen The degree of adoption of the Nitrogen Respirator Requirements, Tests, and Marks (English version) is non-equivalent. The main differences are as follows. --- Modified some formatting formats according to Chinese habits; --- Change some expressions applicable to international standards to those applicable to Chinese standards; --- Added 180 to this category; ---The indicators of quantitative oxygen supply are different; ---The positive pressure performance test method is different; ---Reduced some component requirements. This standard was proposed by the Fire Department of the Ministry of Public Security. This standard is under the jurisdiction of the Fifth Technical Committee of the National Fire Protection Standardization Technical Committee. This standard was drafted. Shanghai Fire Research Institute of the Ministry of Public Security. The main drafters of this standard. Ling Xinliang, Xu Yaoliang, Dai Guoding, Cao Jiasheng, Yin Haibo, Yu Jin, Ma Shanqing. Positive pressure fire oxygen breathing apparatus

1 Scope

This standard specifies the type, technical requirements, test methods, inspection rules, marking, packaging, storage, etc. of positive pressure fire oxygen breathing apparatus. Claim. This standard is applicable to the harsh environment of firefighters and emergency rescue personnel in toxic, anoxic, smog, harmful pollutants suspended in the air. A positive-pressure fire-fighting oxygen breathing apparatus (hereinafter referred to as a respirator) used for disaster relief or disaster relief work. This standard does not apply to positive pressure fire breathing apparatus, submersible breathing apparatus and vacuum breathing apparatus.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard. GB/T 1226-2001 General pressure gauge GB/T 2891-1995 Filtered gas mask mask performance test method Explosion-proof electrical equipment for explosive atmospheres - Part 1. General requirements (eqv IEC 60079-0.1998) GB 3836.4-2000 Explosion-proof electrical equipment for explosive atmospheres - Part 4. Intrinsically safe "i" (eqv IEC 60079-11. 1999) GA 124-2004 Positive pressure fire air breathing apparatus MT867-2000 isolated positive pressure oxygen breathing apparatus

3 Terms and definitions

The following terms and definitions apply to this standard. 3.1 The compressed oxygen is filled with a high-pressure oxygen cylinder as a gas source, and the oxygen in the oxygen cylinder is used when breathing, and the breathing chamber is not dependent on the external environment gas. (or airbag) as a gas storage device, the air pressure in the mask is greater than the external atmospheric pressure of the respirator. 3.2 Includes respiratory protection from masks, breathing tubes, air bags, venting valves, and oxygen supply devices and connectors to the wearer's respiratory organs system. 3.3 After the high pressure oxygen is depressurized, oxygen is continuously supplied to the respiratory system through the orifice at a prescribed flow rate. 3.4 Press the hand to apply the manual replenishment valve directly to the respiratory system.