GA 306.1-2007English399 Add to Cart 3 days [Need to translate] Flame retardant and Fire Resistive cables--Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables--Part 1: Flame retardant cables Obsolete GA 306.1-2007
GA 306.1-2001English239 Add to Cart 3 days [Need to translate] Flame retardant and Fire Resistive cables: Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables Part 1: Flame retardant electric Obsolete GA 306.1-2001

PDF similar to GA 306.1-2007


Standard similar to GA 306.1-2007

GB 14287.3   GB 14287.1   GB 12791   

Basic data

Standard ID GA 306.1-2007 (GA306.1-2007)
Description (Translated English) Flame retardant and Fire Resistive cables--Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables--Part 1: Flame retardant cables
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C81
Classification of International Standard 13.220.20
Word Count Estimation 10,193
Date of Issue 2007-10-17
Date of Implementation 2007-12-01
Older Standard (superseded by this standard) GA 306.1-2001
Quoted Standard GB/T 2951.1; GB/T 2951.2; GB/T 2951.3; GB/T 2951.4; GB/T 2951.5; GB/T 2951.6; GB/T 2951.7; GB/T 2951.8; GB/T 3048.4; GB/T 3048.6; GB/T 3048.8; GB/T 3048.12; GB/T 3048.13; GB/T 3956; GB 5023.1; GB 5023.2; GB 5023.3; GB 5023.4; GB 5023.5; GB 5023.6; GB 5023.7; GB 6995.1; GB 6995
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the definition, technical requirements, test methods, inspection rules, marking and packaging of plastic insulated flame-retardant cables. This standard applies to the rated voltage 35kV and below plastic insulated flame retardant power cable, rated voltage 450, 750 V and below plastic insulated flame retardant control cable and rated voltage 450/750v and below plastic insulated flame retardant cable.

GA 306.1-2007: Flame retardant and Fire Resistive cables--Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables--Part 1: Flame retardant cables



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Flame retardant and Fire Resistive cables--Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables--Part 1. Flame retardant cables ICS 13.220.20 C81 People's Republic of China Public Safety Industry Standard Replacing GA 306.1-2001 Flame retardant and fire resistant cable Plastic insulation flame retardant and fire resistant cable grading and requirements Part 1. Flame-retardant cable Released on October 17,.2007 2007-12-01 implementation Ministry of Public Security

Foreword

5.1 to 5.10 in Chapter 5 of this part are mandatory, and the rest are recommended. GA 306-2007 "Flame-retardant and fire-resistant cable plastic insulation flame retardant and fire-resistant cable grading and requirements" is divided into two parts. --- Part 1. Flame-retardant cable; --- Part 2. Fire resistant cables. This part is the first part of GA 306. This part replaces GA 306.1-2001 "Flame-retardant and fire-resistant cable plastic insulation flame retardant and fire-resistant cable grading and requirements Part 1 Points. Flame retardant cable. Compared with GA 306.1-2001, this section mainly has the following changes. --- Increased corrosion resistance items in the flame retardant grading requirements; --- Technical requirements are specified for the mechanical properties of flame retardant polyolefins, low-smoke low-halogen flame-retardant polyvinyl chloride and other materials. This part is proposed by the Fire Department of the Ministry of Public Security. This part is under the jurisdiction of the 7th Technical Committee of the National Fire Protection Standardization Technical Committee (SAC/TC113/SC7). This section is responsible for drafting the unit. Sichuan Fire Research Institute of the Ministry of Public Security. Participated in the drafting of this section. Jiangsu Provincial Public Security Department Fire Department, Ministry of Public Security Tianjin Fire Research Institute, Baosheng Group Co., Ltd., Guangdong Province Anzhen Fire Department, Sichuan Provincial Public Security Department Fire Bureau. The main drafters of this section. Cheng Dabin, Li Feng, Feng Jun, Gao Ningyu, Dai Dianfeng, Tang Chongjian, Xiao Yiping, Zhou Quanhui. The previous versions of the standards replaced by this section are. ---GA 306.1-2001. Flame retardant and fire resistant cable Plastic insulation flame retardant and fire resistant cable grading and requirements Part 1. Flame-retardant cable

1 Scope

This part of GA 306 specifies the definition, technical requirements, test methods, inspection rules, markings and packaging of plastic insulated flame retardant cables. This part is applicable to plastic insulated flame-retardant power cables with rated voltage of 35kV and below, and plastics with rated voltage of 450/750V and below. Flame-retardant control cable and plastic insulated flame retardant cable with rated voltage of 450/750V and below.

2 Normative references

The terms in the following documents become the provisions of this section by reference to this part of GA 306. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, an agreement is encouraged under this section. The parties are studying whether the latest version of these documents can be used. For undated references, the latest edition applies to the section. GB/T 2951.1 General Test Methods for Cable and Insulating Materials - Part 1. General Test Methods Section 1. Thickness and Shape measurement - mechanical performance test (GB/T 2951.1-1997, idt IEC 60811-1-1..1993) GB/T 2951.2 GB/T 2951.2 General test methods for cable insulation and sheathing materials - Part 1 Test method [GB/T 2951.2-1997, idt IEC 60811-1-2. 1985 No. 1 (1989) 1st revision] GB/T 2951.3 General test methods for cables and sheathing materials - Part 1 Method---Water absorption test---Shrinkage test (GB/T 2951.3-1997, idt IEC 60811-1-3..1993) GB/T 2951.4.General test methods for cable insulation and sheathing materials - Part 1 . General test methods [GB/T 2951.4-1997, idt IEC 60811-4. 1985 No. 1 (1993) 1st amendment] GB/T 2951.5 GB/T. Section. Ozone Resistance Test---Heat Extension Test---Immersion Mineral Oil Test [GB/T 2951.5-1997, idt IEC 60811-2-1. 1986 No. 1 (1992) The first amendment, No. 2 (1993) 2nd revision] GB/T 2951.6 GB/T. Section 1. High temperature pressure test---anti-crack test [GB/T 2951.6-1997, idt IEC 60811-3-1. 1985 No. 1 (1994) 1st Minor correction] GB/T 2951.7 GB/T. Section 2. Weight loss test thermal stability test [GB/T 2951.7-1997, idt IEC 60811-3-2. 1985 No. 1 (1993) the first time Fix] GB/T 2951.8 GB/T. Method Section 1. Environmental Stress Cracking Test---Winding Test after Air Aging---Melt Index Measurement Method---Polyethylene Method for determination of carbon black and/or mineral filler content [GB/T 2951.8-1997, idt IEC 60811-4-1. 1985 No. 1 (1988) 1st Minor correction] GB/T 3048.4 Wire and cable electrical performance test method Conductor DC resistance test (GB/T 3048.4-1994, neqIEC 885-2) GB/T 3048.6 Wire and cable electrical performance test method Insulation resistance test voltage-current meter method (GB/T 3048.6- 1994, neqIEC 885-2) GB/T 3048.8 Wire and cable electrical performance test method AC voltage test (GB/T 3048.8-1994, neqIEC 60.