Heptafluoropropane foam fire extinguishing system
| Obsolete |
GA 1288-2016
|
PDF similar to GA 1288-2016
Standard similar to GA 1288-2016 GB 4351 GA 602 GB 4066.2 GA 999
Basic data | Standard ID | GA 1288-2016 (GA1288-2016) | | Description (Translated English) | Heptafluoropropane foam fire extinguishing system | | Sector / Industry | Public Security (Police) Industry Standard | | Classification of Chinese Standard | C84 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 30,328 | | Date of Issue | 2016-03-10 | | Date of Implementation | 2016-08-10 | | Issuing agency(ies) | Ministry of Public Security |
GA 1288-2016: Heptafluoropropane foam fire extinguishing system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Heptafluoropropane foam fire extinguishing system
ICS 13.220.10
C84
People 's Republic of China Public Security Industry Standard
Hexafluoropropane foam fire extinguishing system
2016-03-10 released
2016-08-10 implementation
Issued by the Ministry of Public Security of the People 's Republic of China
Directory
Preface III
Introduction IV
1 Scope 1
2 normative reference document 1
3 Terms and definitions 1
4 classification and model 2
Technical requirements 3
6 Test Method 10
7 Inspection rules 16
8 signs, packaging, transportation, storage 18
Appendix A (normative appendix) Method for compiling part models 19
Appendix B (normative) System test procedures and number of samples 20
Appendix C (Normative Appendix) Hexafluoropropane Proportional Mixing Unit Test Procedure and Number of Samples 21
Appendix D (Normative Appendix) Procedure and Number of Heptafluoropropane Foam Producers
Appendix E (Normative Appendix) Test procedures and number of samples for heptafluoropropane storage units
Appendix F (Normative Appendix) Test procedures and number of samples for hexafluoropropane control valves 24
Appendix G (Normative appendix) Control cabinet Test procedure and number of samples 25
Foreword
The contents of Chapter 5 and Chapter 7 of this Standard are mandatory and the rest are recommended.
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by the Ministry of Public Security Fire Department.
This standard is owned by the National Fire Safety Standardization Technical Committee of the National Fire Safety System Subcommittee (SAC/TC113/SC2).
This standard is responsible for the drafting unit. Ministry of Public Security Tianjin Fire Research Institute.
This standard participates in the drafting unit. Tianjin Public Security Fire Brigade, Sinopec Qingdao Safety Engineering Research Institute, China Tianchen Engineering Co., Ltd.,
Hangzhou New Age Fire Protection Technology Co., Ltd., Cui Lian (China) Fire Equipment Manufacturing Co., Ltd., Shanghai Golden Shield Fire Safety Equipment Co., Ltd.
The main drafters of this standard. Bai Diantao, Zhiqiang, Liu Lianxi, Luo Zongjun, Tian Liwei, Wang Haijuan, Zhou Jianhong, Wang Yiqing,
On Long Mei, Tang Lin, Wang Junyang, Wang Defeng, Shao Honglin.
This standard is the first release.
Introduction
The issuer of this document drew attention to the fact that the statement may be relevant to the use of the relevant patent (patent number ZL20081
0120340.2, patent number ZL200820163235.2).
The issuer of this document has no position on the authenticity, validity and scope of the patent.
The patent holder has assured the issuing authority of this document that he agrees to grant free permission to any organization or individual on a reasonable, non-discriminatory basis
In the implementation of the industry standard implementation of its patent (patent number ZL200810120340.2, patent number ZL200820163235.2). The patent holds
The statement of the person has been filed with the issuing authority of this document. Related information can be obtained from the following contact information.
Patents. Hangzhou New Era Security Products Co., Ltd., Hangzhou New Era Fire Technology Co., Ltd.
Address. No.3, Tangning Road, Linping Development Zone, Yuhang District, Hangzhou City, Zhejiang Province, China.
Please note that in addition to the above patents, some of the contents of this document may still involve patents. The issuer of this document does not undertake to identify these specialties
Lee's responsibility.
Hexafluoropropane foam fire extinguishing system
1 Scope
This standard specifies the terms and definitions, classification and type, technical requirements, test methods, and inspection of the sevenfluoropropane foam extinguishing systems and components
Rules, signs, packaging, transportation, storage.
This standard applies to heptafluoropropane foam fire extinguishing systems and components.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 3222.2 Description, measurement and evaluation of acoustic environmental noise - Part 2. Determination of ambient noise level
Electrical control equipment GB/T 3797
GB 4208 enclosure protection class (IP code)
General rules for the use of industrial products GB/T 9969
GB 15308 foam fire extinguishing agent
GB 18614 Heptafluoropropane (HFC227ea) Extinguishant
General technical requirements for foam fire extinguishing systems and components GB.20031-2005
Gas fire extinguishing systems and components GB 25972-2010
General technical requirements for drive and control devices for fixed fire extinguishing systems ISO
Foam Spray Fire Extinguishing System
3 terms and definitions
The following terms and definitions apply to this document.
3.1
From the water supply system, the foam liquid storage tank, the foam ratio mixing device, the heptafluoropropane supply device, the heptafluoropropane ratio mixing device,
Alkane foam generators, control cabinets, valves and piping components, can produce sevoflurane foam fire extinguishing system.
3.2
Heptafluoropropaneconcentration
The volume fraction of liquid heptafluoropropane in the mixture of heptafluoropropane.
3.3
Heptafluoropropaneproportioningdevice
And a mixture of liquid heptafluoropropane and a foam mixture at a predetermined mixing ratio.
3.4
Storage pressure storagepressure
The heptafluoropropane storage vessel is filled with heptafluoropropane at the maximum filling density and the internal equilibrium pressure after pressurization at 20 ° C.
|