HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GA 1151-2014 English PDF

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GA 1151-2014English439 Add to Cart 3 days [Need to translate] General requirements for wireless communication function of fire alarm system Obsolete GA 1151-2014

PDF similar to GA 1151-2014


Standard similar to GA 1151-2014

GB 14287.3   GB 14287.1   GB 12791   

Basic data

Standard ID GA 1151-2014 (GA1151-2014)
Description (Translated English) General requirements for wireless communication function of fire alarm system
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C81
Classification of International Standard 13.220.20
Word Count Estimation 10,190
Date of Issue 2014-04-16
Date of Implementation 2014-04-16
Quoted Standard GB 4717; GB/T 9969; GB 12978; GB 14287.1; GB 16808; GB 16838; GB/T 17626.2; GB/T 17626.3; GB 23757
Regulation (derived from) Fire alarm system wireless communication function General requirements "industry standard release implementation; on the publication of public safety industry standard announcement (2014); industry standard filing bulletin 2015 fourth (total 184th)
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the requirements, test, inspection rules and product marks of the wireless communication function in the fire alarm system. This standard applies to the general industrial and civil buildings installed with a wireless communication

GA 1151-2014: General requirements for wireless communication function of fire alarm system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General requirements for wireless communication function of fire alarm system ICS 13.220.20 C81 People's Republic of China Public Security Industry Standards Fire Alarm System wireless communication function General requirements Issued on. 2014-04-16 2014-04-16 implementation People's Republic of China Ministry of Public Security

Foreword

The standard Chapter 3, Chapter 5, Chapter 6 content mandatory, the rest are recommended. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard was proposed by the Ministry of Public Security Fire Department. This standard by the National Standardization Technical Committee on Fire fire detection and alarm Technical Committee (SAC/TC113/SC6) centralized. This standard is drafted by. Ministry of Public Security Shenyang Fire Research Institute. It participated in the drafting of this standard. Versalinks Information Technology (Shanghai) Co., Ltd. The main drafters of this standard. Liu Cheng, Liu Changan, Li Xiaobai, Liuzuo Li, Song Liwei, Zhao Yu, Zhang Binbin, Guo Jinlong, Wei Bin, Qian Shi E, Ding Hongjun. This standard is the first release. Fire Alarm System wireless communication function General requirements

1 Scope

This standard specifies the requirements for a fire alarm system in wireless communication function, testing, inspection rules and product logos. This standard applies to general industrial and civil buildings to install fire alarm system with a wireless communication function, electrical fire monitoring system System and combustible gas alarm system.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4717 fire alarm controller GB/T 9969 General Instructions industrial products GB 12978 fire electronic products inspection rules GB 14287.1 electrical fire control system - Part 1. Electrical fire monitoring equipment GB 16808 combustible gas alarm controller GB 16838 fire electronic products environment test methods and severities GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test GB 23757 fire protection requirements for electronic products

3 Requirements

3.1 General Fire alarm system with a wireless communication function, electrical fire monitoring system and combustible gas alarm system (hereinafter referred to as the "System"), should be First, meet the requirements of Chapter 3, and then press the provisions of Chapter 4 of the test, and meet the test requirements. 3.2 appearance requirements System surface without corrosion, coating loss and blistering, no scratches, cracks, burrs and other mechanical damage, no loose fastening parts. 3.3 Basic functional requirements Various components of the wireless communication system can be complex 3.3.1 within the system to achieve, it can also be used independent of the wireless communication module. 3.3.2 various components within the system having a wireless communication function (including a wireless communication module) should be between the maximum communication distance under the condition, by Wireless communication functions to achieve the following requirements. Fire Alarm a) fire alarm controller, fault alarm function should meet the requirements of GB 4717; b) monitoring alarm electrical fire monitoring equipment, fault alarm function should meet the requirements of GB 14287.1; c) combustible gas alarm controller combustible gas concentration display, combustible gas alarm, fault alarm function should meet GB 16808 requirements. Wireless communication systems 3.3.3 In addition to complying with this standard, it should also comply with the relevant national regulations on radio equipment management.