HOME Cart(0) Quotation About-Us Policies PDFs Standard-List
www.ChineseStandard.net Database: 221904 (15 Apr 2026)
Path: Home > MISC > Page28 > CJ/T 470-2015 || Home > Standard_List > MISC > Page28 > CJ/T 470-2015

CJ/T 470-2015 PDF English

Price & Delivery

US$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
CJ/T 470-2015: Pressure regulator for liquefied dimethyl ether cylinder
Status: Valid
Std IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)Status
CJ/T 470-2015English399 Add to Cart 3 days [Need to translate] Pressure regulator for liquefied dimethyl ether cylinder Valid

Standard similar to CJ/T 470-2015

GB 27790 | GB 25035 | CJ/T 112 | CJ/T 477 | CJ/T 466 | CJ/T 463 |

Basic data

Standard ID CJ/T 470-2015 (CJ/T470-2015)
Description (Translated English) Pressure regulator for liquefied dimethyl ether cylinder
Sector / Industry Urban Construction Industry Standard (Recommended)
Classification of Chinese Standard P47
Classification of International Standard 91.14
Word Count Estimation 17,199
Date of Issue 2015-01-20
Date of Implementation 2015-07-01
Quoted Standard GB/T 1239.2; GB/T 1690; GB/T 1804; GB/T 2828.1; GB/T 2829; GB/T 3934; GB/T 4423; GB 7144; GB/T 7307; GB/T 10922; GB/T 13808; GB/T 13818; GB/T 15115; GB 25035; CJ/T 180-2014
Regulation (derived from) Ministry of Housing and Urban-Rural Development Notice 710
Issuing agency(ies) Ministry of Housing and Urban-Rural Development of the People's Republic of China
Summary This Standard specifies the regulator bottled liquefied dimethyl ether (hereinafter referred to as regulator) classification and models, materials and structures, requirements, test methods, inspection rules, marking, packaging, transportation and storage. This Standard applies to the provisions of GB 25035 of town gas with diethyl ether as the gas source, the inlet pressure of 0.03 MPa ~ 0.94 MPa, the outlet pressure of 2.00 kPa �� 0.50 kPa, the rated flow rate of not more than 3m3/h, use of ambient temperature - regulator 20��C ~ 45��C of. Pressure values ??mentioned in this standard have not traveled label refers to gauge pressure.

CJ/T 470-2015: Pressure regulator for liquefied dimethyl ether cylinder

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Pressure regulator for liquefied dimethyl ether cylinder ICS 91.140 P47 People's Republic of China urban construction industry standards Bottled liquefied dimethyl ether regulator 2015-01-20 released 2015-07-01 implementation Ministry of Housing and Urban-Rural Development, People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 classification and model 2 5 materials and structure 3 6 Requirements 4 7 Test Method 6 8 Inspection rules 10 9 logo, packaging, transportation and storage 11 Appendix A (informative) regulator high and low temperature test device diagram 13

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the Ministry of Housing and Urban Standard and Design Institute. This standard by the Ministry of Housing and Urban Gas Standardization Technical Committee centralized. This standard was drafted. National Gas Appliances Quality Supervision and Inspection Center, China National Institute of Standardization, Wan'an Co., Ltd. Ningbo, Canton East Evergreen (Group) Co., Ltd., Cixi Portman Electric Co., Ltd., Rodolox Valve (Shanghai) Co., Ltd., China Municipal Engineering Cheng North China Design and Research Institute Co., Ltd. The main drafters of this standard. Zhai Jun, Pan Haining, Zhang Feng, Gu Youzhi, Zhang Junfei, Li Bin, with the snow. Bottled liquefied dimethyl ether regulator

1 Scope

This standard specifies the classification of bottled liquefied dimethyl ether regulator (hereinafter referred to as regulator) and type, material and structure, requirements, test side Law, inspection rules, marking, packaging, transportation and storage. This standard applies to urban gas in accordance with GB 25035 with dimethyl ether as the gas source, the inlet pressure of 0.03MPa ~ 0.94MPa, out Mouth pressure of 2.00kPa ± 0.50kPa, the rated flow of not more than 3m3/h, the use of ambient temperature -20 ℃ ~ 45 ℃ regulator. The pressure mentioned in this standard where unlabeled mean gauge pressure.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1239.2 Cold rolled cylindrical coil springs - Part 2. Compression springs GB/T 1690 vulcanized rubber or thermoplastic rubber liquid test methods GB/T 1804 General tolerances Tolerances for linear and angular dimensions without tolerances GB/T 2828.1 Sampling procedures for inspection - Part 1. Batch inspection sampling plan by acceptance quality limit (AQL) GB/T 2829 cycle test count sampling procedures and tables (for the stability of the test process) GB/T 3934 ordinary thread gauge technical conditions GB/T 4423 copper and copper alloy rod GB 7144 cylinder color logo GB/T 7307 55 ° non-sealed pipe thread GB/T 10922 55 ° non-sealed pipe thread gauge GB/T 13808 copper and copper alloy extruded rod GB/T 13818 die-cast zinc alloy GB/T 15115 die-cast aluminum GB 25035 town gas with dimethyl ether CJ/T 180-2014 Manual Gas Valve for Construction

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Reference state referencestate Drying gas at 15 ° C and absolute pressure of 101.325 kPa. 3.2 Turn off stress lockuppressure Turn off the regulator outlet valve and stabilize the pressure at the regulator outlet at zero flow.
CJ/T 470-2015 English cover page

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of CJ/T 470-2015_English be delivered?

Answer: Upon your order, we will start to translate CJ/T 470-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of CJ/T 470-2015_English with my colleagues?

Answer: Yes. The purchased PDF of CJ/T 470-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.