GB 9706.224-2021 PDF English
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| GB 9706.224-2021 | 635 | Add to Cart | Auto, 9 seconds. | Medical electrical equipment - Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers | Valid |
Similar standards
GB 9706.224-2021: Medical electrical equipment - Part 2-24: Particular requirements for the basic safety and essential performance of infusion pumps and controllers
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB9706.224-2021
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 CCS C 31 Replacing GB 9706.27-2005 Medical electrical equipment - Part 2-24.Particular requirements for the basic safety and essential performance of infusion pumps and controllers (IEC 60601-2-24.2012, MOD) Issued on: DECEMBER 01, 2021 Implemented on: MAY 01, 2023 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword... 3 Introduction... 8 201.1 Scope, object and related standards... 10 201.2 Normative references... 12 201.3 Terms and definitions... 13 201.4 General requirements... 17 201.5 General requirements for testing of ME EQUIPMENT... 19 201.6 Classification of ME EQUIPMENT and ME SYSTEMS... 19 201.7 ME EQUIPMENT identification, marking and documents... 19 201.8 Protection against electrical HAZARDS from ME EQUIPMENT... 24 201.9 Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS... 24 201.10 Protection against unwanted and excessive radiation HAZARDS... 24 201.11 Protection against excessive temperatures and other HAZARDS... 24 201.12 Accuracy of controls and instruments and protection against hazardous outputs ... 26 201.13 HAZARDOUS SITUATIONS and fault conditions... 47 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)... 47 201.15 Construction of ME EQUIPMENT... 48 201.16 ME SYSTEMS... 49 201.17 Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS... 50 202 Electromagnetic compatibility – Requirements and tests... 50 206 Usability... 51 208 General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems... 52 Annexes... 56 Annex AA (informative) Particular guidance and rationale... 57 Bibliography... 75Foreword
This document was drafted in accordance with the rules given in GB/T 1.1-2020, Directives for standardization - Part 1.Rules for the structure and drafting of standardizing documents. This document is part 2-24 of GB 9706, Medical electrical equipment. The following parts have been published under GB 9706. -- Part 1.General requirements for basic safety and essential performance; -- Part 1-3.General requirements for basic safety and essential performance - Collateral Standard. Radiation protection in diagnostic X-ray equipment; -- Part 2-1.Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV; -- Part 2-2.Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories; -- Part 2-3.Particular requirements for the basic safety and essential performance of short-wave therapy equipment; -- Part 2-5.Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment; -- Part 2-6.Particular requirements for the basic safety and essential performance of microwave therapy equipment; -- Part 2-8.Particular requirements for the basic safety and essential performance of therapeutic X-ray equipment operating in the range 10 kV to 1 MV; -- Part 2-11.Particular requirements for the basic safety and essential performance of gamma beam therapy equipment; -- Part 2-12.Particular requirements for basic safety and essential performance of critical care ventilators; -- Part 2-13.Particular requirements for the basics safety and essential performance of an anaesthetic workstation; -- Part 2-16.Particular requirements for the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment; -- Part 2-17.Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy after loading equipment; -- Part 2-18.Particular requirements for the basic safety and essential performance of endoscopic equipment; -- Part 2-19.Particular requirements for the basic safety and essential performance of infant incubators; -- Part 2-24.Particular requirements for the basic safety and essential performance of infusion pumps and controllers; -- Part 2-25.Particular requirements for the basic safety and essential performance of electrocardiographs; -- Part 2-26.Particular requirements for the basic safety and essential performance of electroencephalographs; -- Part 2-27.Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment; -- Part 2-28.Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis; -- Part 2-29.Particular requirements for the basic safety and essential performance of radiotherapy simulators; -- Part 2-36.Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy; -- Part 2-37.Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment; -- Part 2-39.Particular requirements for basic safety and essential performance of peritoneal dialysis equipment; -- Part 2-43.Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures; -- Part 2-44.Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography; -- Part 2-45.Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices; Medical electrical equipment - Part 2-24.Particular requirements for the basic safety and essential performance of infusion pumps and controllers 201.1 Scope, object and related standards Clause 1 of the general standard applies, except as follows. 201.1.1 Scope Replacement. This particular standard specifies the requirements for ENTERAL NUTRITION PUMPS, INFUSION PUMPS, INFUSION PUMPS FOR AMBULATORY USE, SYRINGE OR CONTAINER PUMPS, VOLUMETRIC INFUSION CONTROLLERS and VOLUMETRIC INFUSION PUMPS, as defined in 201.3.204, 201.3.206, 201.3.207, 201.3.220, 201.3.222 and 201.3.223. This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS, hereafter referred to as ME EQUIPMENT. This standard applies to ADMINISTRATION SETS as far as their characteristics influence the BASIC SAFETY or ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS. However this Standard does not specify requirements or tests for other aspects of ADMINISTRATION SETS. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this Standard are not covered by specific requirements in this Standard except in 7.2.13 and 8.4.1 of the general standard. Note. See also 4.2 of the general standard. This Standard does not apply to the following. a) devices specifically intended for diagnostic or similar use (e.g., angiography or other pumps permanently controlled or supervised by the OPERATOR); ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.