Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB 9706.27-2005 PDF English

US$165.00 · In stock · Download in 9 seconds
GB 9706.27-2005: Medical electrical equipment -- Part 2-24: Particular requirements for the safety of infusion pumps and controllers
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Obsolete
Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB 9706.27-2005165 Add to Cart Auto, 9 seconds. Medical electrical equipment -- Part 2-24: Particular requirements for the safety of infusion pumps and controllers Obsolete

Similar standards

GB/T 14233.1   GB 8368   GB/T 14232.2   GB 9706.255   

GB 9706.27-2005: Medical electrical equipment -- Part 2-24: Particular requirements for the safety of infusion pumps and controllers


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB9706.27-2005
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.20 C 31 GB 9706.27-2005 / IEC 60601-2-24.1998 Medical electrical equipment - Part 2-24.Particular requirements for the safety of infusion pumps and controllers (IEC 60601-2-24.1998, IDT) Issued on: NOVEMBER 24, 2005 Implemented on: AUGUST 1, 2006 Issued by. General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration Committee.

Table of Contents

Foreword... 5 Introduction... 7 SECTION ONE - GENERAL... 8 1 Scope and object... 8 2 Terminology and definitions... 10 3 General requirements... 15 4 Test general requirements... 16 5 Classification... 17 6 Identification, marking and documents... 18 SECTION TWO - ENVIRONMENTAL CONDITIONS... 25 8 Basic safety type... 25 10 Environmental conditions... 25 SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS ... 25 14 Requirements related to classification... 25 17 SEPARATION... 26 18 Protective grounding, functional grounding and potential equalization... 28 19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS... 29 20 Dielectric strength... 32 SECTION FOUR- PROTECTION AGAINST MECHANICAL HAZARDS... 32 21 Mechanical strength... 33 SECTION FIVE- PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION... 34 36* Electromagnetic compatibility... 34 SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES... 35 40 Requirements and tests for type AP equipment and its parts and components... 35 41 Requirements and tests for type APG equipment and its parts and components... 36 SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS... 36 43 Fire prevention... 36 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization, disinfection and compatibility... 37 47 Electrostatic charges... 39 48 Material of applied part in contact with patient’s body... 39 48 Biocompatibility... 40 49 Interruption of the power supply... 40 SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT... 40 50 Accuracy of operating data... 41 51 Protection against hazardous output... 62 SECTION NINE - Abnormal operation and fault conditions; environmental test ... 68 52 Abnormal operation and fault conditions... 68 SECTION TEN - CONSTRUCTIONAL REQUIREMENTS... 69 Annex L (Informative) References... 78 Annex AA (Informative) General guidance and rationale... 79 Annex BB (Normative) Normative references... 108

Foreword

There are series of standards of medical electrical equipment, which mainly consist of two parts. - Part 1.general safety requirements for medical electrical equipment; - Part 2.particular requirements for medical electrical equipment. This Particular Standard is particular requirements for the safety of infusion pumps and controllers of Part 2.This Standard identically uses IEC 60601-2- 24.1998 Medical electrical equipment - Part 2-24.Particular requirements for the safety of infusion pumps and controllers (English version). Compared with IEC 60601-2-24.1998, the editorial differences in this Particular Standard are as follows. - for other International standards used as references in IEC 60601-2- 24.1998, if they have been used in China standards, it shall replace the reference numbers of the International standards by China’s; - for easy use, added the normative Annex BB “Normative references”; modified the informative Annex L “Bibliography” and incorporated part of the standard directory into Annex BB; - the content of Clause 36 of IEC 60601-2-24.1998 used the standard of IEC 60601-1-2.1993 but this edition (Edition 1993) has been replaced by Edition 2001, therefore Clause 36 of this Particular Standard uses requirements of YY 0505-2005; - incorporated the relevant requirements of Amendment 2 (1995) of IEC 60601-1.1988 into corresponding terms of this Standard so as to make this Particular Standard consistent with IEC 60601-2-24.1998.to make it distinguished with particular standard, the content of Amendment 2 has been marked by double vertical line in this Particular Standard. This Particular Standard uses GB 9706.1-1995 Medical electrical equipment-- Part 1.General requirements for safety (idt IEC 60601-1.1988 + Amendment 1 (1991)) and IEC 60601-1.1998 Amendment 2 (1995) Medical electrical equipment--Part 1.General requirements for safety Amendment 2, YY 0505- 2005 Medical electrical equipment Part 1-2.General requirements for safety - Collateral standards. Electromagnetic compatibility - Requirements and tests (IEC 60601-1-2.2001, IDT) as references. Annex L, Annex AA of this Particular Standard are informative; Annex BB is normative. This Particular Standard was proposed by Sub-committee on Medical Electronic Equipment of National Technical Committee on Medical Electrical Equipment of Standardization Administration of China. This Particular Standard shall be under the jurisdiction of Sub-committee on Medical Electronic Equipment of National Technical Committee on Medical Electrical Equipment of Standardization Administration of China. The drafting organization of this Particular Standard. Shanghai Institute of Medical Instrumentation. Main drafters of this Particular Standard. Xu Yuemin, Liu Qun. Medical electrical equipment - Part 2-24.Particular requirements for the safety of infusion pumps and controllers SECTION ONE - GENERAL The clauses and sub-clauses of this section of the General Standard and of this section of the Collateral Standard YY 0505-2005 apply, except as follows.

1 Scope and object

The clause of the General Standard and this clause of the Collateral Standard YY 0505-2005 apply, except as follows. 1.1* Scope Addition. This Particular Standard specifies the requirement for infusion pumps, infusion controllers, syringe pumps and pumps for ambulatory use, as defined in 2.101 to 2.110.These devices are intended for use by medical staff and home patients as prescribed and medically indicated. These particular requirements do not apply to devices. - specifically intended for diagnostic or similar use (e.g. angiography or other pumps permanently controlled or supervised by the operator); - enteral infusion; - extracorporeal circulation of blood; - implantable or disposable devices; - equipment specially intended for diagnostic use within urodynamics (measurement of pressure-volume relationship of the urinary bladder when filled through a catheter with water); - equipment specially intended for diagnostic use within male impotence testing (measurement of amount of liquid infused, necessary to maintain a preset pressure level for maintaining penile erection. cavernosometry, cavernosography). Annex BB (Normative) Normative references The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (exc... ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB 9706.27-2005 be delivered?Answer: The full copy PDF of English version of GB 9706.27-2005 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB 9706.27-2005_English with my colleagues?Answer: Yes. The purchased PDF of GB 9706.27-2005_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 9706.27-2005 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB 9706.27-2005?

A step-by-step guide to download PDF of GB 9706.27-2005_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB 9706.27-2005".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9