HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (1 Sep 2024)

YD/T 777-2006 PDF in English


YD/T 777-2006 (YD/T777-2006, YDT 777-2006, YDT777-2006)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
YD/T 777-2006English160 Add to Cart 0-9 seconds. Auto-delivery. Inversion equipment for telecommunications Obsolete
YD/T 777-2021English479 Add to Cart 4 days (Inverter equipment for communication) Valid
Newer version: YD/T 777-2021    Standards related to: YD/T 777-2021
PDF Preview

YD/T 777-2006: PDF in English (YDT 777-2006)

YD/T 777-2006 YD Communication Industry Standard of the People’s Republic of China Replacing YD/T 777-1999 Inversion equipment for telecommunications ISSUED ON. MAY 31, 2006 IMPLEMENTED ON. OCTOBER 1, 2006 Issued by. The Ministry of Industry and Information Technology of the People’s Republic of China Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Definitions ... 6  4 Product classification ... 7  5 Requirements ... 8  6 Test methods ... 15  7 Inspection rules ... 23  8 Marks, packaging, transportation and storage ... 25  Appendix A ... 26  Appendix B ... 27  Appendix C ... 30  Foreword This Standard replaces YD/T 777-1999 Inversion equipment for telecommunications. Compared with the YD/T 777-1999, this Standard has the following major changes. — This Standard is drafted according to the format requirements specified in the GB/T 1.1-2000. — DELETE the reference to the GB 7260. — ADD the definition “3.7 Peak factor”. — REVISE “4.1.3.1” of the original version. ADD “1.5” and “4” to this Standard. — REVISE “5.2” of the original version. MODIFY the allowable variation range of the input voltage to 40 ~ 57.6V. — DELETE “5.2.2” of the original version. — REVISE the contents in the “5.4.2” of the original version. MODIFY the “power factor 0.7” to “power factor 0.8” in Note 2 of the table. DECREASE the AC output current rating. — REVISE the contents in the “5.4.8” of the original version. STIPULATE the AC output frequency rating as 50Hz. SEE 5.4.7 of this version. — REVISE “5.4.9” of the original version. CANCEL the restriction of “2MHz”. SEE 5.4.8 of this version. — REVISE the headline of the “5.4.12” of the original version. MODIFY the “conversion mode” to the “conversion time”. SEE 5.4.11 of this version. — REVISE the contents in the “5.4.13” of the original version. ADD the input requirements for inrush starting current. SEE 5.4.12 of this version. — REVISE “5.4.14” of the original version. MODIFY the sentences. SEE 5.4.13 of this version. — REVISE the contents in the “5.4.15” of the original version. MAKE the grading rules for overload capacity. SEE 5.4.14 of this version. — DELETE the requirements for temperature rise specified in the “5.4.16” Inversion equipment for telecommunications 1 Scope This Standard specifies the technical conditions, test methods, and inspection rules of the DC-AC sine wave inversion equipment for telecommunications (hereinafter referred to as “inversion equipment”), which are required for accommodating the special requirements for communication equipment. This Standard applies to the sine wave inversion equipment providing power supply for the communication equipment. 2 Normative references The provisions in the following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard. However, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest versions apply to this Standard. GB/T 191 Packaging – Pictorial marking for handling of goods GB/T 2423.1-2001 Environmental testing for electric and electronic products – Part 2. Test methods – Tests A. Cold GB/T 2423.2-2001 Environmental testing for electric and electronic products – Part 2. Test methods – Tests B. Dry heat GB/T 2423.9-2001 Environmental testing for electric and electronic products – Part 2. Test methods – Test Cb. Damp heat, steady state, primarily for equipment GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 3047.1 Series of basic dimensions of panels, rack and cabinets for vertical increment of 20mm GB/T 3859.2 Semiconductor convertors – Application guide GB/T 3873 General specifications for products packaging of communication equipment 3.7 Peak factor It refers to the ratio OF the peak value of the periodic load current TO its effective value, which is generally used for measuring the inversion equipment’s ability of carrying non-linear loads. 3.8 Total harmonic distortion (THD) It refers to the percentage OF the root mean square value of the distortion content TO that of the fundamental component in the AC quantity. 3.9 Harmonic content It refers to the value obtained after the fundamental component is subtracted from the AC quantity. Note. Harmonic content can be expressed as time functions or root mean square values. 4 Product classification 4.1 Product types, specifications and series 4.1.1 Product types a) Single-phase sine wave inversion equipment; b) Three-phase sine wave inversion equipment; c) Redundant single-phase or three-phase sine wave inversion equipment in parallel. 4.1.2 Input voltage rating series SELECT 48V from the following numerical values as the DC input voltage rating of inversion equipment. Note. After the user puts forward the requirement and negotiates with the manufacturer, the products beyond the above numerical values can also be produced. 4.1.3 Output power rating series (in unit of kVA) 4.1.3.1 Single-phase sine wave inversion equipment or single-phase sine wave inverter unit 0.5, 1, 1.5, 2, 3, 4, 5 and 10. Note. After the user puts forward the requirement and negotiates with the manufacturer, the products from the heat sources. 5.1.2 Special operating conditions If it is necessary to use the inverter under the conditions which are different from the normal operating conditions specified in the Section 5.1.1, the user shall put forward when placing orders, and shall make an agreement with the manufacturer. For instance. a) The inversion equipment used in abnormal mechanical stress, such as vehicular communication; b) The inversion equipment operating in tropical climates with high humidity and high temperature; c) The inversion equipment used in the environments where the atmospheric pressure exceeds the range of 86kPa ~ 106kPa; d) Marine inversion equipment, or the inversion equipment operating in maritime climates. 5.2 Input conditions of DC power supplies The DC input voltage is 48V. The allowable variation range is 40V~ 57.6V. Note. After the user puts forward the requirement and negotiates with the manufacturer, the inversion equipment beyond the above numerical values can also be produced. 5.3 Input conditions of AC power supplies The inversion equipment can be provided with bypass power supply devices. The AC power supplies providing power supply for the bypass devices shall conform to the following requirements. a) The allowable variation range of AC voltage shall be 85% to 110% of the rated value; b) The frequency rating and the allowable deviation of AC voltage shall be respectively 50Hz and ± 5%; c) The unbalance degree of three-phase AC voltage shall not be greater than 10%; d) The phase deviation of three-phase AC voltage shall not be greater than 5° electrical degree. Note. After the user puts forward the requirement and negotiates with the manufacturer, the products beyond the above numerical values can also be produced. Table 2 Conduction Disturbance Limits of AC Output Voltage Frequency range (MHz) Limits dB (μV) Quasi-peak Mean value 0.15~0.5 79 66 0.5~30 73 60 5.4.5 Unbalance degree of three-phase output voltage During the nominal voltage input, and under the load conditions specified in the specific product standards, the unbalance degree of three-phase output voltage shall not be greater than 5%. 5.4.6 Phase deviation of three-phase output voltage During the nominal voltage input, and under the load conditions specified in the specific product standards, the phase deviation of three-phase output voltage shall not be greater than 5° electrical degree. 5.4.7 Output frequency ratings and stabilizing accuracy The AC output frequency rating is 50Hz. When the input voltage and load current (resistive load) are within the allowable variation range, the stabilizing accuracy of the output frequency shall not be greater than ± 2%. 5.4.8 Reflected wide band noise current at the input When the input voltage, output voltage, and output current (resistive load) operate at rated values, the wide band noise component in the DC current (root mean square value) shall be less than 10% of the DC current. 5.4.9 Reflected relative psophometrically weighted noise current at the input When the input voltage, output voltage, and output current (resistive load) operate at rated values, the reflected relative psophometrically weighted noise current at the input s... ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.