HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (2 Nov 2024)

QB/T 1242-1991 (QB/T 1242-2021 Newer Version) PDF English


QB/T 1242-1991 (QB/T1242-1991, QBT 1242-1991, QBT1242-1991)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
QB/T 1242-2021English439 Add to Cart 4 days Installation dimension for furniture hardware Valid
QB/T 1242-1991English105 Add to Cart 0-9 seconds. Auto-delivery. Furniture Hardware Installation Dimension of Cyathiform Blind Hinge Obsolete
Newer version: QB/T 1242-2021     Standards related to (historical): QB/T 1242-2021
PDF Preview

QB/T 1242-1991: PDF in English (QBT 1242-1991)

QB/T 1242-1991 QB LIGHT INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Furniture hardware -- Installation dimension of cup hinge ISSUED ON: SEPTEMBER 10, 1991 IMPLEMENTED ON: APRIL 01, 1992 Issued by: Ministry of Light Industry of PRC Table of Contents 1 Subject content and scope of application ... 3  2 Terms ... 3  3 Parameters and parameter relations ... 4  4 Structure ... 6  5 Installation dimensions ... 7  6 Compilation of installation instructions ... 8  Appendix A The 0°~90° motion trajectory of cup hinge (Informative) ... 9  Appendix B Installation dimension of strip base (Informative) ... 11  Additional information ... 12  Furniture hardware -- Installation dimension of cup hinge 1 Subject content and scope of application This standard specifies the basic installation dimensions of cup hinges for furniture. This standard applies to the design, manufacture, installation of cup hinges for furniture. 2 Terms 2.1 Overlay type The installation method where the door is overlaid on the front side of the side panel. Commonly known as overlay door, cover door. 2.2 Inset type The installation method where the front side of the side panel is on the same plane as the door surface OR protrudes from the door surface. Commonly known as suction door, upper door, entrance door. 2.3 Strip base A base in straight form (see Figure 3). During installation, the axis connection of the two mounting holes or pins on the strip base shall be kept perpendicular to the front side of the side panel. 2.4 Wing base The base which has lugs on both sides (see Figure 3). During installation, the axis connection of the two mounting holes or pins on the lugs of base shall be kept parallel to the front side of the side panel. 2.5 Design datum plane The reference plane which is determined by the cup hinge's manufacturer when designing the relevant parameters. When the base is connected with the hinge arm, meanwhile the adjusting screw is in a loosened state, the reference plane is parallel to the plane of the base. 2.6 Zero base In the cup hinge's base series, the base whose bottom plane coincides with the design datum plane. 3 Parameters and parameter relations 3.1 Parameter A The design parameter that indicates the relative installation position between the door and the side panel. It is, when the door is in a 90° closed position as relative to the side panel, the distance from the side of the door to the inner surface of the side panel. See Figure 1. 3.2 Parameter B The design parameter that indicates the degree of bending of the hinge arm. It is, when the door is in a 90° closed position as relative to the side panel, the distance FROM the design datum plane TO the outer tangent plane of the cylindrical surface of the hinge cup, on the side of the nearest door. See Figure 1. 3.3 Parameter C The design parameter that indicates the relative position between the hinge cup hole and the side of the door. It is the minimum distance from the side of the door to the cylindrical surface of the hinge cup. See Figure 1. 3.4 Parameter H Design parameter that indicates the relative position between the design datum plane and the inner surface of the side panel. It is the distance from the design datum plane to the inner surface of the side panel. See Figure 1. When the parameter H > 0, use the bases of different thickness series OR zero bases plus gaskets, to meet the value of H. 3.7 Parameter L When the parameter H = 0, AND the door is opened to a position which is parallel to the side panel, the distance BETWEEN the inner surface of the door AND the inner surface of the side panel. See Figure 2. 3.8 Parameter relationship The algebraic relationship of parameters A, B, C, H is H = A + B + C. For the cover-mounted type, the A value is negative; for the flush-mounted type, the A value is positive. When the design datum plane is perpendicular to the hinge cup's installation plane, for the design datum plane's position as relative to the cylindrical surface of the hinge cup closest to the door side: when separated, the value of B is negative; when it is tangent, the value of B is zero; when intercrossed, the value of B is positive. In any case, the C value is positive, When H ≥ 0, the is an effective design. In addition to the above-mentioned parameter relations, for the mutual restrictive relation of related parameters AND the movement trajectory diagram of the cup hinge, refer to Appendix A. 4 Structure Cup hinges are generally composed of the following items: hinge cups, connecting plates, hinge arms, bases, fastening screws, adjusting screws. The schematic diagram is as shown in Figure 3: with the wing base. 5.4 On the door and side panel, for the distance of mounting holes of the cup hinges, the machining error shall be controlled within ±0.2 mm. 6 Compilation of installation instructions 6.1 The cup hinge's manufacturer shall include the following contents into the product manual. a. The structure and dimensions of the cup hinge and the installation parts of its base; b. The types, specifications, quantities of applicable standard parts and other connection accessories; c. Applicable assembly diagram and parameter indications; d. Parameter relationship H = A + B + C; e. The series parameter values of parameter H; f. The series parameter value of parameter B, including the indication of positive and negative; g. Table of δXmax values corresponding to different door thicknesses and different C values; h. Within the value range of C, when δYmax appears, it shall also list the δYmax values; i. Provision of the L value corresponding to different B values, OR one of them; j. The maximum adjustment in the three-dimensional direction of the installed door. 6.2 The cup hinge's manufacturer shall, when calculating the parameter relationship, not use the adjustment quantity of the adjusting screw as the insertion compensation quantity. A2.2 The values of the parameters δXmax and δYmax vary with the variation of the trajectory curve of point a and point b. However, the trajectory curve of point a and point b vary with the variation of the following conditions. a. In the four-bar linkage mechanism, as long as the original coordinate's position of one joint changes, the trajectory curve of point a and point b will also change. b. When the parameter value of parameter C is changed, it is equivalent to making the four-bar linkage mechanism translate in the X-axis direction. Therefore, the trajectory curve of point a and point b will also change. c. When the thickness value of the door is changed, the coordinate position of point a, as relative to the four-bar linkage mechanism, has changed. Therefore, the trajectory curve of point a will change accordingly. Therefore, for a cup hinge that has been determined, the value of the parameter δXmax will be restricted by the parameter C and the door thickness; whilst the parameter δYmax is only restricted by the parameter C. A2.3 The value of parameter A is restricted by the parameter δXmax. A2.4 When there is δYmax, it is necessary to check the installation gap of the door in the depth direction of the cabinet. A2.5 In the area where the door opens from the 0° position to the 90° position, the parameters δXmax and δYmax are thereby defined. Therefore, this Figure is also suitable for cup hinges which have an opening angle greater than 90°. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.