Determination of carbon and hydrogen in coal
| Valid |
GB/T 476-2001 | English | 479 |
Add to Cart
|
4 days
|
Ultimate analysis of coal
| Obsolete |
GB/T 476-1991 | English | 519 |
Add to Cart
|
4 days
|
Ultimate analysis of coal
| Obsolete |
PDF Preview: GB/T 476-2008
GB/T 476-2008: PDF in English (GBT 476-2008) GB/T 476-2008
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 73.040
D 21
Replacing GB/T 476-2001, GB/T 15460-2003, GB/T 18856.11-2002
Determination of carbon and hydrogen in coal
(ISO 625:1996, Solid mineral fuels - Determination of carbon and hydrogen -
Liebig method, MOD)
ISSUED ON: JULY 29, 2008
IMPLEMENTED ON: MAY 01, 2009
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Three-stage furnace method and two-stage furnace method ... 5
4 Coulometric-gravimetric method ... 16
5 Method precision ... 24
6 Test report ... 25
Appendix A (Informative) Comparison of clause numbers between this standard
and ISO 625:1996 ... 26
Appendix B (Informative) The technical differences between the chapter
numbers of this standard and ISO 625:1996 and their reasons ... 27
Determination of carbon and hydrogen in coal
1 Scope
This standard specifies the method principles, reagents and materials, devices,
test procedures, result calculation, precision, etc., of the three-stage furnace
method, two-stage furnace method, electricity consumption method, for the
determination of the hydrogen in the coal and coal-water slurry dried coal
sample, AND the weight method for the determination of carbon, in the carbon
and hydrogen analysis of coal and coal-water slurry.
This standard applies to lignite, bituminous coal, anthracite, coal-water slurry.
2 Normative references
The provisions in following documents become the provisions of this Standard
through reference in this Standard. For the dated references, the subsequent
amendments (excluding corrections) or revisions do not apply to this Standard;
however, parties who reach an agreement based on this Standard are
encouraged to study if the latest versions of these documents are applicable.
For undated references, the latest edition of the referenced document applies.
GB/T 212 Proximate analysis of coal (GB/T 212-2008, ISO 11722:1999, ISO
1171:1997, ISO 562:1998, NEQ)
GB/T 218 Determination of carbon dioxide content in the mineral carbonates
associated with coal (GB/T 218-1996, eqv ISO 925:1980)
GB/T 18856.1 Test methods for quality of coal water mixture - Part 1:
Sampling for coal water mixture
3 Three-stage furnace method and two-stage furnace
method
3.1 Method principle
A certain amount of coal sample OR coal-water slurry dried coal sample is
burned in an oxygen flow; the generated water and carbon dioxide are
absorbed by a water absorbent and a carbon dioxide absorbent, respectively;
the mass fraction of carbon and hydrogen, in the coal, is calculated from the
increase of the absorbent. The interference of sulfur and chlorine, in coal
samples, on carbon determination, is eliminated by lead chromate and silver
wire coils, in the three-stage furnace; it is eliminated by the pyrolysis product of
silver permanganate, in the two-stage furnace. The interference of nitrogen on
carbon determination, is eliminated by granular manganese dioxide.
3.2 Reagents and materials
3.2.1 Anhydrous magnesium perchlorate: Analytically pure, which has a particle
size of 1 mm ~ 3 mm. OR anhydrous calcium chloride: Analytically pure, which
has a particle size of 2 mm ~ 5 mm.
3.2.2 Granular manganese dioxide: Chemically pure, which is commercially
available or prepared from manganese sulfate and potassium permanganate.
Preparation method: Weigh 25 g of manganese sulfate. Dissolve it in 500 mL
of distilled water. Weigh another 16.4 g of potassium permanganate. Dissolve
in 300 mL of distilled water. The two solutions are heated to 50 °C ~ 60 °C,
respectively. Slowly pour the potassium permanganate solution, into the
manganese sulfate solution, with constant stirring. Vigorously stir it. Then add
10 mL of (1 + 1) sulfuric acid. Heat the solution to 70 °C ~ 80 °C. Continue to
stir for another 5 min. Stop heating. Let it stand for 2 h ~ 3 h. Use hot distilled
water, to pour-wash it to neutrality. Move the precipitate into a funnel for
filtration, to remove moisture. Then place it in a drying oven, for drying, at about
150 °C, for 2 h ~ 3 h, to obtain brown, loose manganese dioxide. Carefully crush
and sieve it, to obtain a particle size of 0.5 mm ~ 2 mm, for later use.
3.2.3 Copper wire coil: The wire diameter is about 0.5 mm. Copper wire mesh:
0.15 mm (100 mesh).
3.2.4 Copper oxide: Chemically pure, linear (about 5 mm in length).
3.2.5 Lead chromate: Analytically pure, which is prepared to a particle size of 1
mm ~ 4 mm.
Preparation method: Use distilled water, to mix commercially available lead
chromate into a paste. Extrude to shape it. Put it in a muffle furnace. Burn it at
850 °C, for 2 h. Take it out. Cool it, for later use.
3.2.6 Silver wire coil: The wire diameter is about 0.25 mm.
3.2.7 Oxygen: 99.9%, without hydrogen. Oxygen cylinders need to be equipped
with a pressure gauge, which has a pressure reducing valve with adjustable
flow (medical oxygen inhalers can be used).
3.2.8 Tungsten trioxide: Analytically pure.
3.2.9 Soda asbestos: Chemically pure, which has a particle size of 1 mm ~ 2
Figure 1 -- Schematic diagram of the carbon and hydrogen analyzers by
three-segment furnaces and two-stage furnaces
3.3.1.1 Purification system, including the following components:
a) Gas drying tower: Capacity 500 mL, 2 units, the upper part (about 2/3) of
one unit (A) is filled with anhydrous calcium chloride (or anhydrous
magnesium perchlorate), the lower part (about 1/3) is filled with alkali
asbestos (or soda lime); another one unit (B) is filled with anhydrous
calcium chloride (or anhydrous magnesium perchlorate);
b) Flowmeter: Measuring range (0 ~ 150) mL/min.
3.3.1.2 Combustion device: It consists of a three-stage (or two-stage) pipe
furnace and its temperature control system, mainly including the following
components:
a) Electric furnace: three-stage furnace or two-stage furnace (double-pipe
furnace or single-pipe furnace); the diameter of the furnace is about 35
mm.
Three-stage furnace: The first stage is about 230 mm long, which can be
heated to (850 ± 10) °C, AND can move in the horizontal direction; the
second stage is 330 mm ~ 350 mm long, which can be heated to (800 ±
10) °C; the third stage is 130 mm ~ 150 mm long, which can be heated to
(600 ± 10) °C.
Two-stage furnace: The first stage is about 230 mm long, which can be
heated to (850 ± 10) °C, AND can move in the horizontal direction; the
second stage is 130 mm ~ 150 mm long, which can be heated to (500 ±
10) °C.
Each stage of the furnace is equipped with thermocouples, temperature
measurement, temperature control devices.
b) Combustion pipe: It is made of bisque, quartz, corundum or stainless steel,
which is about 1100 mm ~ 1200 mm in length (about 800 mm in length
when using a two-stage furnace), has an inner diameter of 20 mm ~ 22
mm, AND a wall thickness of about 2 mm.
c) Burning boat: It is made of bisque or quartz, at about 80 mm long.
d) Rubber stopper or rubber cap (preferably with heat-resistant silicone
rubber) or copper joint.
e) Nickel-chromium wire hook: It is about 2 mm in diameter AND about 700
mm in length; one end is bent into a hook.
Connect the containers of the absorption system, which is prepared in
accordance with the requirements of 4.3.5, in the order as shown in Figure 6.
Use polyvinyl chloride hoses or polytetrafluoroethylene pipes, to connect the
oxygen purification system and the combustion pipe. Use silicon rubber pipe,
to connect the electrolytic cell and the U-shaped pipe, AND to connect the U-
shaped pipe and U-shaped pipe.
When the following phenomena occur, the reagents in the U-shaped pipe shall
be replaced, OR the electrolytic cell shall be cleaned.
a) After a certain test, when the mass of the second U-shaped pipe for
absorbing carbon dioxide increases by more than 50 mg, the first U-
shaped pipe shall be replaced;
b) Manganese dioxide, anhydrous magnesium perchlorate or anhydrous
calcium chloride shall generally be replaced, after about 100 times of use;
meanwhile it shall be replaced, when the calcium chloride in the water-
absorbing U-shaped pipe begins to melt and hinders the smooth flow of
gas;
c) When the electrolytic cell is used about 100 times OR when the electrolytic
cell is found to have tailings, etc., the electrolytic cell shall be cleaned and
re-coated.
4.4.5 Air tightness inspection of the measuring system
Adjust the oxygen flow to about 80 mL/min; the others are the same as 3.4.5.
4.4.6 Reliability inspection of test device
Carry out according to 3.4.6. BUT weigh 0.070 g ~ 0.075 g of standard coal
sample, accurate to 0.0002 g.
4.5 Test procedure
4.5.1 Select the polarity of the electrolysis power supply (it shall be
interchanged once a day). Lead in oxygen and adjust the flow to about 80
mL/min. Connect the cooling water. Turn on the power to heat up.
4.5.2 At the same time as the temperature rises, connect the U-shaped pipe for
carbon dioxide absorption (the ground plug of the U-shaped pipe shall be
opened first) and the bubble meter, to keep the oxygen flow rate at about 80
mL/min. Press the electrolysis key (or pretreatment key) to the end. Then, press
the electrolysis key (or pretreatment key) every 2 min ~ 3 min. After 10 min,
remove the U-shaped pipe for carbon dioxide absorption. Close all the ground
plugs of the U-shaped pipe. Place it next to the balance, for about 10 min. Weigh
it. Then connect to the system and repeat the above test, until the mass change
of the two U-shaped pipes for carbon dioxide absorption does not exceed
0.0005 g.
4.5.3 Control the temperature of the combustion furnace, purification furnace,
catalytic furnace, at the specified temperature. Mix the coal samples evenly.
Weigh 0.070 g ~ 0.075 g of coal samples for general analysis, which have a
particle size of less than 0.2 mm, in a pre-burned burning boat, accurate to
0.0002 g. Spread them evenly. Cover with a layer of tungsten trioxide. If the
measurement is not performed immediately, the burning boat can be
temporarily stored in an airtight container without desiccant.
4.5.4 Connect a U-shaped pipe for carbon dioxide absorption with constant
mass. Keep the oxygen flow at about 80 mL/min. Start electrolysis, to the end
of electrolysis. Zero the hydrogen integral value and time counter. Open the
rubber stopper with the nickel-chromium wire push rod. Quickly put the burning
boat into the inlet end of the combustion pipe. Plug the rubber stopper with the
push rod. Use the push rod to push the burning boat, so that half of it enters the
burner opening. After the coal sample is burned (generally 30 s), press the
electrolysis key (or the determination key). When the coal sample burns stably,
push the whole boat into the furnace opening. Stay for about 2 minutes. Then
push the burning boat into the high temperature zone AND immediately pull
back the push rod (do not let the red-hot part of the push rod pull close to the
rubber stopper, so as not to cause the rubber stopper to be overheated and
decomposed).
4.5.5 After about 10 minutes (the electrolysis reaches the end point; otherwise,
the time needs to be extended appropriately), remove the U-shaped pipe for
carbon dioxide absorption. Close the ground stopper. Place it next to the
balance for about 10 minutes, before weighing. If the mass change of the
second U-shaped pipe for carbon dioxide absorption is less than 0.0005 g, it is
ignored in the calculation. Record the mass (mg) of hydrogen, which is
displayed by the coulometric integrator. Open the rubber stopper with push rod.
Use a nickel-chromium wire hook, to take out the burning boat. Plug the rubber
stopper with push rod.
4.5.6 Determination of blank value
4.5.6.1 The determination of the hydrogen blank value can be carried out
simultaneously, with the constant mass test of the U-shaped pipe for carbon
dioxide absorption; OR it can be carried out after the determination of carbons
and hydrogens.
4.5.6.2 After the combustion furnace, purification furnace, catalytic furnace
reaches the specified temperature, keep the oxygen flow at about 80 mL/min.
Start electrolysis to the end point. Add tungsten trioxide to a pre-burned burning
boat (the amount is equivalent to that of coal sample analysis). Zero the
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|