GB/T 11344-2021 PDF English (GB/T 11344-2008: Older version)


Search result: GB/T 11344-2021 (GB/T 11344-2008 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 11344-2021English470 Add to Cart 0-9 seconds. Auto-delivery. Non-destructive testing - Ultrasonic thickness measurement Valid
GB/T 11344-2008English879 Add to Cart 4 days Non-destructive testing -- Practice for measuring thickness by ultrasonic pulse-echo contact method Obsolete
GB/T 11344-1989English279 Add to Cart 3 days Measuring thickness by ultrasonic pulse-echo contact method Obsolete


PDF Preview: GB/T 11344-2021


GB/T 11344-2021: PDF in English (GBT 11344-2021)

GB/T 11344-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 19.100 CCS J 04 Replacing GB/T 11344-2008 Non-destructive Testing - Ultrasonic Thickness Measurement (ISO 16809:2017, NEQ) ISSUED ON: MAY 21, 2021 IMPLEMENTED ON: DECEMBER 1, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions... 5 4 Method Summary ... 5 5 General Requirements ... 8 6 Measurement Preparation ... 10 7 Instrument Settings ... 14 8 Testing Reports and Records ... 17 Appendix A (informative) Ultrasonic Sound Velocity of Common Engineering Application Materials ... 19 Appendix B (informative) Ultrasonic Thickness Measurement of Corrosion of Vessels and Pipelines ... 22 Appendix C (informative) Selection of Measurement Method ... 29 Appendix D (informative) Factors Affecting Measurement Accuracy ... 33 Appendix E (informative) Instrument Settings under Special Testing Conditions ... 44 Bibliography ... 46 Non-destructive Testing - Ultrasonic Thickness Measurement 1 Scope This Standard specifies the ultrasonic thickness measurement through the ultrasonic pulse-echo contact method. This Standard is applicable to the ultrasonic thickness measurement of metal and non- metal materials. 2 Normative References The contents of the following documents constitute the indispensable clauses of this document through the normative references. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 9445 Non-destructive Testing - Qualification and Certification of NDT Personnel (GB/T 9445-2015, ISO 9712:2012, IDT) GB/T 12604.1 Non-destructive Testing - Terminology - Ultrasonic Testing (GB/T 12604.1-2020, ISO 5577:2017, MOD) GB/T 20737 Non-destructive Testing - General Terms and Definitions (GB/T 20737- 2006, ISO/TS 18173:2005, IDT) GB/T 36439 Non-destructive Testing - Certification and Qualification of Aerospace Non-destructive Testing Personnel 3 Terms and Definitions The terms and definitions defined in GB/T 12604.1 and GB/T 20737 are applicable to this document. 4 Method Summary 4.1 By measuring the time for the ultrasonic signals transmitted by the probe to pass through the measured material for one, two or multiple times, the thickness of the measured material is determined. The thickness is calculated by dividing the product of the already-known sound velocity and the pulse echo time by the number of pass- 5.1.4 The ultrasonic flaw detector with A-scan display measures thickness by reading the distance between the initial pulse and the first back wall echo after the calibration of the zero point and sound velocity, or through the A-scan display of the distance between multiple back wall reflection echoes on the baseline during the calibration. 5.1.5 The ultrasonic thickness gauges shall be calibrated in accordance with the currently effective methods every year and satisfy the requirements for use. 5.2 Probes 5.2.1 Ultrasonic thickness measurement shall adopt dual-element or single-element longitudinal-wave probes. 5.2.2 The other specific requirements for the probes are shown in 6.3. 5.3 Coupling Agent 5.3.1 Ultrasonic thickness measurement satisfies the acoustic coupling between the probe and the material by applying fluid or gel. The coupling agent shall have good sound permeability and have no adverse effects on the tested materials, equipment and operating personnel. 5.3.2 The selected coupling agent shall be suitable for the irregularities of the surface condition and shape of the tested product, so as to ensure sufficient coupling. 5.3.3 The requirements for the coupling agents used under special measurement conditions are shown in 6.4. 5.4 Calibration Blocks The sound velocity and thickness of the calibration blocks shall be already-known, and identical or similar to the material of the tested product. The calibration blocks can be in a set or a step. The thickness of the blocks should cover the thickness range of the tested product. A thickness value of the blocks shall not be less than the maximum thickness of the measurement range, and the other thickness value of the block shall not be greater than the minimum thickness of the measurement range. The production of steel step blocks for thickness measurement may take GB/T 39432 as a reference. The production of other materials of blocks for thickness measurement may also take this document as a reference. 5.5 Testing Personnel 5.5.1 The personnel performing ultrasonic thickness measurement in accordance with this document shall be subjected to personnel qualification or certificate in accordance with GB/T 9445, GB/T 36439 or the system agreed by all parties to the contract, obtain the qualification certificate for the ultrasonic testing personnel, and receive on-the-job training and authorization by the employer or agent. 5.5.2 The testing personnel shall understand the characteristics of the tested product and material. 6 Measurement Preparation 6.1 Surface Condition 6.1.1 The surface of the tested product shall be clean and flat, and free of loose surface or non-sticky coatings. The measurement contact area shall be not less than 2 times the diameter of the probe. Poor contact may cause the loss of acoustic energy and changes in signal and sound beam propagation paths. 6.1.2 If there is a coating on the measurement surface, then, the coating shall be well- combined with the material. The existence of close-fitting coatings (such as: paint and enamel, etc.) is allowed. Only a few thickness gauges can measure the thickness of the coating. When measuring the thickness of a coated product, the thickness of the coating and the sound velocity shall be already-known, otherwise, Method 3 (multiple- echo method) shall be adopted for the measurement. 6.1.3 Generally, the surface of corroded and abrasive products is relatively rough and a little corroded, or there may be other defects (see Appendix B). The corroded surface shall be polished to remove rust spots. During polishing, the thickness shall not be reduced to below the acceptable minimum value. 6.2 Selection of Methods 6.2.1 General requirements 6.2.1.1 Ultrasonic thickness measurement is usually applied to the following two fields: ---measurement during manufacture; ---in-service measurement of residual wall thickness. 6.2.1.2 In accordance with the material, geometrical shape and thickness of the tested product, as well as the requirements for measurement accuracy, appropriate instruments and measurement methods shall be selected. See Appendix C and Appendix D. 6.2.1.3 The accuracy of thickness measurement depends on the accuracy of acoustic time measurement. Adopt different modes for the time measurement (zero-crossing measurement, leading-edge measurement and peak-value measurement). The accuracy of Method 3 (multiple-echo method) is higher than that of Method 1 and Method 2. When the measurement is conducted on the basis of different frequencies, the measurement accuracy of high-frequency probe is higher than that of low- frequency probe. narrow sound beam width, so as to accurately measure the restricted area, and penetrate the entire thickness range. 6.3.3 For thin materials, high-damping and high-frequency probes are generally used. High-frequency (10 MHz or higher) delay block probe can be used for the measurement of steel materials with a thickness of about 0.6 mm; dual-element probes with a small focal length may also be adopted for the measurement of thin materials. For the dual-element probes, the focal length range shall cover the thickness range of the tested product. 6.3.4 When measuring products with a relatively small thickness, the delay block probe and Method 2 or Method 3 may be used for the measurement. When the acoustic impedance of the delay block material is relatively low, for example, plastic delay block being placed on the metal for measurement, the interface echo may generate a phase shift, which shall be corrected to obtain accurate measurement results. Some thickness gauges have the function of automatic correction. 6.3.5 When the surface temperature of the material is relatively high, and the delay block is used as a thermal barrier, the delay block shall be able to withstand the temperature of the tested product. Before measurement, the influence of temperature on the acoustic characteristics of the delay block (acoustic attenuation and sound velocity drift) shall be grasped. The probe manufacturer shall provide the temperature range, in which, the probe can be used, and the service time under the measurement temperature. 6.3.6 In accordance with different thicknesses and materials, the frequency range of the probes may be between 100 kHz for the measurement of high-attenuation materials and 50 MHz for the measurement of thin metals sheets. 6.3.7 If the dual-element probe is used, the error of the V-shaped path of acoustic wave transmission shall be compensated. Generally, when measuring thin materials, the propagation time of the dual-element probe no longer has a linear relationship with the thickness. The smaller the measured thickness is, the more serious the non-linearity becomes. The schematic diagram of the variation is shown in Figure 2 a); the typical error value is shown in Figure 2 b). required for measurement recommended by the manufacturer. 6.4.4 Measurement in hazardous environment 6.4.4.1 When measuring in hazardous environment, the current laws and regulations on safety shall be strictly abided by. 6.4.4.2 In a corrosive environment, the coupling agent shall not adversely react with the environment and shall maintain the acoustic characteristics. 7 Instrument Settings 7.1 Settings of Ultrasonic Flaw Detector with A-scan display 7.1.1 Combination of ultrasonic flaw detector with A-scan display and direct- contact single-element probe 7.1.1.1 The starting point of display is synchronized with the initial pulse, and the time baseline shall be linear. The entire thickness range is displayed on the A-scan. 7.1.1.2 Fine-tune the delay control and subtract the propagation time in the protective film. The calibration blocks shall provide at least two thicknesses covering the measured thickness range, so as to calibrate the accuracy of the entire measurement range. 7.1.1.3 Place the probe on a block with already-known thickness; adjust the instrument control (sound velocity calibration, range, scanning or sound velocity), until the echo displays an appropriate thickness reading. 7.1.1.4 On the block whose reading value is less than the thickness value, examine and adjust to improve the accuracy of the system. If necessary, re-verify on the intermediate thickness of the step block. 7.1.2 Combination of ultrasonic flaw detector with A-scan display and delay block single-element probe 7.1.2.1 When using the delay block single-element probe, the instrument shall be able to correct the time of passing the delay block, so that it can correspond to zero thickness at the end of the delay. The instrument shall have “delay” control or electronic automatic zero adjustment function. 7.1.2.2 If the sound velocity can be adjusted in advance to the sound velocity of a given material, then, it can be calibrated through the method of adjusting the delay control, until the instrument displays the correct thickness value. If the sound velocity cannot be set, the following methods may also be used to set the instrument. a) Use at least two blocks. The thickness of one test block is not smaller than 7.1.4.2 After the basic setting is completed, adjust the scan delay. For example, the nominal thickness of the tested product is 50 mm ~ 60 mm, the calibration block is 10 mm, and the thickness range is also 50 mm ~ 60 mm. Adjust the delay control, so that the 5th back side reflection of the calibration block is equal to 50 mm, which coincides with the reference zero point on the A-scan display; the 6th back side echo shall be on the right side of the calibration scanning line. 7.1.4.3 After setting is completed, verify on a block with an already-known approximate total thickness. 7.1.4.4 The reading obtained on the unknown block shall be added with the value delayed outside the fluorescent screen. For example, if the reading is 4 mm, then, the total thickness is 54 mm. 7.1.5 Instrument settings for thickness measurement of high-attenuation materials For high-attenuation materials, Method 4 (through-transmission method) may be adopted for thickness measurement. The transmitted pulse indication may be used to indicate a zero time pulse; set it to zero scale and set the location of the received pulse signal to align with the already-known thickness on the scale. 7.2 Settings of Digital Direct-reading Ultrasonic Thickness Gauge 7.2.1 The instrument shall have the functions of “sound velocity setting” (or “material selection” or “sound velocity correction”) and “zero correction”. 7.2.2 Usually, the blocks with the same material as the tested product are used. One with a thickness not smaller than the maximum value of the measured thickness, and the other with a thickness not greater than the minimum value of the measured thickness. 7.2.3 The probe is placed on the thicker block; adjust the “sound velocity setting” of the instrument, so that the reading displayed by the thickness gauge is close to the known value. 7.2.4 The probe is placed on the thinner block; adjust the “zero correction” of the instrument, so that the reading displayed by the thickness gauge is close to the known value. 7.2.5 Repeat 7.2.3 and 7.2.4, until correct readings can be obtained on both the high and low ends of the thickness range. 7.2.6 If the sound velocity of the material is known, then, the sound velocity value can be set in advance. Then, measure the thin steel block attached to the instrument; adjust the “zero correction”, so that the instrument displays the values of different materials after conversion. B.2 Measurement of General Corrosion B.2.1 Instruments B.2.1.1 When the surface condition does not satisfy the requirements, the tested product has inclusions or relatively thick coatings, and the instrument cannot provide reliable readings, the ultrasonic flaw detector with A-scan display should be used. B.2.1.2 When there is a coating on the measurement surface and the thickness of the coating needs to be eliminated from the result, the instrument of Method 3 should be selected. B.2.1.3 When finding the thinnest point in a given area, the thickness gauge or flaw detector with A-scan display should be used. B.2.2 Probes B.2.2.1 The selection of the probes depends on the instrument type, material thickness, surface condition and coating conditions. B.2.2.2 For the digital direct-reading ultrasonic thickness gauge, the probes specified by the manufacturer should be used. B.2.2.3 For instruments with A-scan display, the following guidelines should be abided by in the selection of probes. ---The selection of the probe frequency should be such that the wavelength in the measured material is at least 1.5 times the measured thickness (see D.1.3 of Appendix D). ---When the thickness of the tested product is not less than 10 mm, the single- element probe should be selected. The multiple-echo technique (Method 3) is only applicable to the single-element probe. ---When the thickness of the tested product is less than 10 mm, the dual-element probe should be selected for measurement. ---When the thickness of the tested product is less than 5 mm, the dual-element probe with a special focal length should be used for measurement. ---When the surface of the tested product is curved, a suitable probe element diameter should be selected to satisfy the requirements for acoustic coupling. ---For the tested products with a coating, the single-element probe, in combination with Method 3, should be selected for measurement; the compensation of the coating thickness is allowed. B.2.3 Measurement B.2.3.1 When reading multiple back wall echoes (merely for single-element probe), obtain an accurate result by reading the nth echo and dividing the reading by n. When measuring the thickness of a product with a coating on the surface, read the distance from echo 1 to echo n and divide it by n - 1. The coating thickness is not included in the obtained measurement result. B.2.3.2 When the measurement of only one back wall echo is conducted, the reading should be taken at the same echo position as when the instrument was calibrated. If there is a coating on the surface, then, the coating thickness is included in the reading, and the coating thickness shall be subtracted from the measurement result. B.2.3.3 If the requirement for measurement repeatability is high, then, the location of the measurement point shall be separately recorded. When the thinnest point in a given area needs to be measured, generally, an instrument with A-scan [5.1.1 b) or 5.1.1 c)] is used for measurement. B.2.3.4 The application of digital display thickness gauge shall comply with the manufacturer’s instructions. B.2.3.5 When the measurement is abnormal due to the internal discontinuity of the material, supplementary testing should be carried out, for example, using an oblique probe to verify the accuracy of the measurement result. B.3 Measurement of Corrosion with Pitting B.3.1 Instrument An instrument with A-scan [5.1.1 b) or 5.1.1 c)] should be used to measure the thickness of possible pitting. B.3.2 Probes The dual-element probe should be selected for the testing of pitting. The focal length of the probe shall be able to reach the predicted distance of the pitting. B.3.3 Instrument settings On a step block whose thickness range covers the thickness of the tested product, perform the instrument settings. The material and temperature of the block shall be the same as the tested product. When the existence of small-diameter pitting is doubtful, on a small-diameter flat-bottomed block with the same depth as the pitting distance, the sensitivity of the testing shall be determined for verification. B.3.4 Measurement ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.