GB 44016-2024 PDF English


Search result: GB 44016-2024
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB 44016-2024English515 Add to Cart 0-9 seconds. Auto-delivery. Electro-magnetic emergency shut-off valve for gas Valid


GB 44016-2024: PDF in English

GB 44016-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 91.140 CCS P 47 Electro-magnetic Emergency Shut-off Valve for Gas ISSUED ON. APRIL 29, 2024 IMPLEMENTED ON. AUGUST 1, 2024 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword... 4 1 Scope... 5 2 Normative References... 5 3 Terms and Definitions... 7 4 Classification and Models... 7 4.1 Classification... 7 4.2 Model... 7 5 Material and Structure... 8 5.1 Material... 8 5.2 Structure... 10 6 Requirements... 13 6.1 General Requirements... 13 6.2 Appearance... 14 6.3 Case... 14 6.4 Strength of Pressure-bearing Parts... 14 6.5 Air Tightness... 14 6.6 Rated Flow... 15 6.7 Emergency Shut-off Performance... 15 6.8 Torque Resistance... 16 6.9 Bending Resistance... 16 6.10 Impact Resistance... 16 6.11 Durability... 17 6.12 Temperature Resistance and Damp Heat Resistance... 17 6.13 Valve Position Status Indication... 17 6.14 Electrical Safety... 17 6.15 Explosion-proof Performance (Ex)... 18 6.16 Protection Performance (IP)... 18 6.17 Properties of Non-metallic Materials... 18 6.18 Corrosion Resistance... 18 6.19 Temperature Rise of Electromagnetic Coil... 18 6.20 Electromagnetic Compatibility Safety... 18 7 Test Methods... 19 7.1 Test Conditions... 19 7.2 Appearance Inspection... 20 7.3 Case Inspection... 20 7.4 Strength Test of Pressure-bearing Parts... 20 7.5 Air Tightness Test... 20 7.6 Rated Flow Test... 21 7.7 Emergency Shut-off Performance Test... 23 7.8 Torque Resistance Test... 24 7.9 Bending Resistance Test... 25 7.10 Impact Resistance Test... 26 7.11 Durability Test... 26 7.12 Temperature Resistance and Damp Heat Resistance Test... 27 7.13 Valve Position Status Indication Test... 27 7.14 Electrical Safety Test... 27 7.15 Explosion-proof Performance Test... 28 7.16 Protection Performance Test... 28 7.17 Non-metallic Material Properties Test... 28 7.18 Corrosion Resistance Test... 28 7.19 Temperature Rise Test of Electromagnetic Coil... 28 7.20 Electromagnetic Compatibility Safety Test... 28 8 Inspection Rules... 29 8.1 Inspection Items... 29 8.2 Exit-factory Inspection... 29 8.3 Type Inspection... 29 9 Marking and Instructions for Use... 30 9.1 Marking... 30 9.2 Instructions for Use... 31 10 Packaging, Transportation and Storage... 31 10.1 Packaging... 31 10.2 Transportation... 32 10.3 Storage... 32 Electro-magnetic Emergency Shut-off Valve for Gas 1 Scope This document defines the terms and definitions of electro-magnetic emergency shut-off valve for gas; specifies the classification and model, material and structure, and requirements; describes corresponding test methods; clarifies the inspection rules, and the requirements for marking and instructions for use, packaging, transportation, and storage, etc. This document is applicable to electro-magnetic emergency shut-off valves for gas installed on gas user pipelines where the maximum working pressure is not greater than 0.4 MPa and the nominal dimension is not greater than DN300, and the transmission media are natural gas, liquefied petroleum gas (including liquefied petroleum gas mixed with air) and artificial gas (hereinafter referred to as the “shut-off valves”). 2 Normative References The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 229 Metallic Materials - Charpy Pendulum Impact Test Method GB/T 699 Quality Carbon Structure Steels GB/T 700 Carbon Structural Steels GB/T 1173 Casting Aluminum Alloy GB/T 1220 Stainless Steel Bars GB/T 1239.2 Cold Coiled Helical Springs Technical Specifications - Part 2.Compressions Spring GB/T 1348 Spheroidal Graphite Iron Castings GB/T 1591 High-strength Low-alloy Structural Steel GB/T 1690-2010 Rubber, Vulcanized or Thermoplastic - Determination of the Effect of Liquids GB/T 3191 Extrusion Rods and Bars of Aluminum and Aluminum Alloys GB(/T) 3836 (all parts) Explosive Atmospheres GB/T 4208 Degrees of Protection Provided by Enclosure (IP code) b) Springs with a metal wire diameter less than or equal to 2.5 mm shall be made of corrosion-resistant materials. Springs with a metal wire diameter greater than 2.5 mm shall be made of corrosion-resistant materials or other materials with anti-corrosion protection. 5.1.3 Non-metallic materials 5.1.3.1 Non-metallic materials in contact with gas shall be gas-resistant. 5.1.3.2 The surface of rubber parts shall be smooth and free of defects, such as. bubbles, lack of glue and delamination, etc. 5.1.3.3 The O-shaped rubber sealing ring shall comply with the provisions of GB/T 23658. 5.1.4 Electrical components 5.1.4.1 The cable materials shall comply with the provisions of GB/T 5013.1 and GB/T 5023.1. 5.1.4.2 The electromagnetic coil enameled wire shall be copper enameled wire and comply with the relevant provisions of GB/T 6109 (all parts). 5.1.4.3 The material of the electromagnetic coil case shall comply with the provisions of non- metallic cases and non-metallic components of the case, metal case and metal components of the case in GB(/T) 3836 (all parts). 5.2 Structure 5.2.1 Design pressure Pressure-bearing parts include metal components that bear pressure during normal operation and components that bear pressure after the pressure differential seal fails. When the maximum working pressure is 0.01 MPa or 0.1 MPa, the design pressure shall be 0.4 MPa; when the maximum working pressure is 0.4 MPa, the design pressure shall be 0.6 MPa. 5.2.2 Structural length The structural length shall comply with the provisions of GB/T 12221. 5.2.3 Structural design 5.2.3.1 The mass and dimensions of the shut-off valve materials and the assembly method of each component shall ensure that the structure of the shut-off valve has sufficient strength and shall be able to withstand the mechanical stress that it may experience during installation and maintenance. 5.2.3.2 Shut-off valves with nominal dimensions less than or equal to DN50 shall be threaded or flanged. Shut-off valves with nominal dimensions greater than DN50 shall be flanged. 5.2.3.3 Except for the aluminum alloy flange, the dimensions and sealing surface types of other 6.1.3 The current shall comply with the following requirements. a) If the power supply is used to directly drive the coil to generate electromagnetic force, indicate the maximum current; b) If capacitor discharge is used to obtain the electromagnetic force, indicate the discharge current; c) If there are internal circuits and other electronic components, indicate the static power consumption. 6.2 Appearance 6.2.1 The shut-off valves shall be made of anti-corrosion materials, or the surface shall be treated with anti-corrosion and anti-trust, etc. The coating shall be uniform, consistent in color, and free of defects, such as. peeling, cracks, and bubbles, etc. 6.2.2 The installation and pasting of signs shall be smooth, and shall not be scratched, warped, or peeled off. The content on the signs shall be complete and the writing shall be clear and correct. 6.3 Case In addition to complying with the requirements of 5.1.1.1, the shut-off valves with nominal dimensions greater than DN25 shall also adopt a metal case to protect the electromagnetic coil. 6.4 Strength of Pressure-bearing Parts After being subjected to the test in accordance with the provisions of 7.4, the pressure-bearing parts shall have no deformation, no cracks, and no visible leakage. 6.5 Air Tightness Carry out the test in accordance with the method specified in 7.5, and one of the following requirements must be satisfied. a) When inspected with leak detection fluid or immersed in water, there shall be no visible leaks; b) When tested by the pressure drop method, the internal air tightness and external air tightness leakage of the shut-off valve shall not exceed the provisions of Table 5. 7 Test Methods 7.1 Test Conditions 7.1.1 General atmospheric conditions When there are no special requirements, the test shall be carried out under the following atmospheric conditions. a) Ambient temperature. 15 C ~ 35 C; b) Relative humidity. 45% ~ 75%; c) Atmospheric pressure. 86 kPa ~ 106 kPa. 7.1.2 Test media 7.1.2.1 Medium for strength test of pressure-bearing parts. non-corrosive liquid with a temperature higher than 5 C and a viscosity not higher than water, dry air, or nitrogen. 7.1.2.2 Medium for air tightness test. dry air or nitrogen. 7.1.3 General provisions for test 7.1.3.1 During the test, the shut-off valve shall be installed or placed in the normal working position. 7.1.3.2 Unless otherwise specified, knocking or vibration of the shut-off valve under test is not allowed during the test. 7.1.3.3 The set values shall be corrected to the standard basal state. 7.1.4 Selection of instruments and devices for tests 7.1.4.1 The requirements for the selection of pressure gauges for the strength test of pressure- bearing parts. a) The measuring range of the pressure gauge shall be 1.5 ~ 3 times the test pressure; b) The accuracy of the pressure gauge shall not be lower than Level 1.6. 7.1.4.2 The requirements for the selection of instruments and devices for the air tightness test. a) The measuring range of the pressure gauge used for low-pressure internal air tightness shall not be higher than 5 kPa, and the measuring range of other pressure gauges shall be 1.5 ~ 3 times the test pressure; b) The accuracy of the pressure gauge shall not be lower than Level 0.4; 7.5.1.1 The shut-off valve is in the open position, with both ends closed. The test pressure is 1.5 times the maximum working pressure. 7.5.1.2 When adopting leak detection fluid or water immersion for inspection, slowly apply pressure to the shut-off valve to the specified test pressure, and the pressure holding time shall not be lower than 3 minutes. Determine whether the test result complies with the provisions of 6.5 a). 7.5.1.3 When adopting the pressure drop method, slowly apply pressure to the shut-off valve to the specified test pressure and maintain the pressure. Check the leakage of the shut-off valve and determine whether the test result complies with the provisions of 6.5 b). 7.5.2 Internal air tightness 7.5.2.1 The shut-off valve is in the closed position, the air inlet end is closed, and the air outlet end is open. The test pressure is 0.6 kPa and 1.5 times the maximum working pressure. 7.5.2.2 When adopting leak detection fluid or water immersion for inspection, slowly apply pressure to the air inlet end of the shut-off valve to two specified test pressures. For the shut- off valves with nominal dimensions less than DN50, the pressure holding time shall not be lower than 1 minute. For the shut-off valves with nominal dimensions greater than or equal to DN50, the pressure holding time shall not be lower than 3 minutes. Determine whether the test result complies with the provisions of 6.5 a). 7.5.2.3 When adopting the pressure drop method, slowly apply pressure to the air inlet end of the shut-off valve to two specified test pressures and maintain the pressure. Check the leakage of the shut-off valve and determine whether the test result complies with the provisions of 6.5 b). 7.6 Rated Flow Test 7.6.1 Test device As shown in Figure 2, connect the test device. The maximum error of the test instrument shall not exceed 2%. of 6.11. 7.12 Temperature Resistance and Damp Heat Resistance Test 7.12.1 High temperature (operation) resistance test Place the shut-off valve that has completed the durability test in the test chamber, connect the cable of the shut-off valve, adjust the temperature of the test chamber, and maintain it at 20 C  5 C for 30 min  5 min. At a rate of 1 C/min, raise the temperature to 60 C  2 C, maintain it for 16 hours, then, immediately carry out the test in accordance with 7.5 and 7.7.Take out the shut-off valve and place it under normal atmospheric conditions for 1 h ~ 2 h. Visually inspect the specimen for coating damage or corrosion and determine whether the test result complies with the provisions of 6.12.1. 7.12.2 Low temperature (operation) resistance test Place the shut-off valve that has completed the high temperature (operation) resistance test in the test chamber, connect the cable of the shut-off valve, adjust the temperature of the test chamber, and maintain it at 20 C  5 C for 30 min  5 min. At a rate of 1 C/min, lower the temperature to 20 C  2 C (applicable to shut-off valves within the normal ambient temperature range) or 40 C  2 C (applicable to shut-off valves within the low ambient temperature range), maintain it for 16 hours, then, immediately carry out the test in accordance with 7.5 and 7.7.Take out the shut-off valve and place it under normal atmospheric conditions for 1 h ~ 2 h. Visually inspect the specimen for coating damage or corrosion and determine whether the test result complies with the provisions of 6.12.2. 7.12.3 Constant heat and humidity (operation) resistance test Place the shut-off valve that has completed the low temperature (operation) resistance test in the test chamber, connect the cable of the shut-off valve, adjust the temperature of the test chamber, and maintain it at 20 C  5 C for 30 min  5 min. At a rate of 1 C/min, raise the temperature to 40 C  2 C, humidify to a relative humidity of 90% ~ 95%, maintain it for 16 hours, then, immediately carry out the test in accordance with 7.5 and 7.7.Take out the shut- off valve and place it under normal atmospheric conditions for 1 h ~ 2 h. Visually inspect the specimen for coating damage or corrosion and determine whether the test result complies with the provisions of 6.12.3. 7.13 Valve Position Status Indication Test During shut-off and reset, respectively check whether the conversion of the valve position indication is reliable, and check whether the identification is consistent with the open and closed status of the valve. Determine whether the test result complies with the provisions of 6.13. 7.14 Electrical Safety Test In accordance with the corresponding requirements in Appendix E of GB/T 30597-2014, carry out the test, and determine whether the test result complies with the provisions of 6.14. 7.15 Explosion-proof Performance Test Check the explosion-proof certificate, or in accordance with the relevant requirements in GB(/T) 3836 (all parts), carry out the test. Determine whether the test result complies with the provisions of 6.15. 7.16 Protection Performance Test In accordance with the relevant requirements in GB/T 4208, carry out the test, and determine whether the test result complies with the provisions of 6.16. 7.17 Non-metallic Material Properties Test 7.17.1 Gas resistance test Soak non-metallic materials in 98% (volume fraction) n-pentane liquid (applicable to natural gas and liquefied petroleum gas), or liquid B (applicable to artificial gas) specified in Appendix A of GB/T 1690-2010.In accordance with the method specified in GB/T 1690-2010, carry out gas resistance test, and determine whether the test result complies with the provisions of 6.17.1. 7.17.2 Low temperature resistance test Place the non-metallic sealing materials at 20 C  2 C (applicable to shut-off valves within the normal ambient temperature range) or 40 C  2 C (applicable to shut-off valves within the low ambient temperature range), maintain for 24 hours. Then, determine whether the test result complies with the provisions of 6.17.2. 7.18 Corrosion Resistance Test Adopt the salt spray test equipment, neutral salt spray test reagent and test method specified in GB/T 10125 to carry out the test for 96 hours. Determine whether the test result complies with the provisions of 6.18. 7.19 Temperature Rise Test of Electromagnetic Coil In accordance with the requirements of Chapter 15 in GB/T 14536.1-2022, carry out the test. The ambient temperature of the test is 60 C  2 C. Determine whether the test result complies with the provisions of 6.19. 7.20 Electromagnetic Compatibility Safety Test Before the test, the shut-off valve shall be maintained in the normal working condition. In accordance with the requirements of Appendix F in GB/T 30597-2014, carry out the test. The duration of the voltage sag is 1 cycle. Determine whether the test result complies with the provisions of 6.20. a) Trial production and type appraisal of new products; b) Trial production and type appraisal for factory transfer production; c) After formal production, when there are significant changes in structure, materials and processes that may affect product performance; d) When production is resumed after two years of suspension; e) When the exit-factory inspection results are significantly different from the previous type inspection; f) When relevant national departments or organizations request for type inspection. 8.3.2 The type inspection items are as specified in Table 14. 9 Marking and Instructions for Use 9.1 Marking 9.1.1 Marking on nameplate The shut-off valves shall have a fixed nameplate in an obvious position, and its content shall at least include. a) Product name and model; b) Nominal dimensions; c) Explosion-proof “Ex” mark, explosion-proof type and level; d) Explosion-proof certificate No.; e) Rated voltage, frequency, and power; f) IP protection degree; g) Maximum working pressure; h) Working medium; i) Product No.; j) Date of production; k) Manufacturer’s name and trademark. 9.1.2 Warning signs The setting of warnings signs for the shut-off valves shall comply with the relevant provisions of GB(/T) 3836 (all parts). 9.1.3 Valve body mark 9.1.3.1 The direction of gas flow shall be permanently marked with an arrow on the valve body. 9.1.3.2 The DN, furnace (batch) No. and material designation mark shall be marked on the valve body in accordance with GB/T 12220 and JB/T 106.When the valve body is too small to cast (diecast or forge) the above-mentioned marks, it is allowed to be expressed by imprinting or attaching a plate. When flange-connected valves are used, the flange shall be marked with nominal pressure. 9.2 Instructions for Use When exiting the factory, the products shall be accompanied by instructions for use, and its content shall at least include. a) Product structural diagram and working principle. b) Technical parameters, in addition to the parameters marked on the nameplate, shall also include. ---working environment temperature range and medium temperature range; ---power, rated air flow when the pressure difference between the inlet and outlet of the shut-off valve is 100 Pa, shut-off time, and weight. c) Product installation (including connection mode, connection dimensions and serial No. of implemented Standard) and wiring instructions (including valve closing signal information). d) Precautions for product usage. e) Repair, maintenance and quality warranty period. f) Commonly seen faults and troubleshooting methods. g) Special precautions and warning statements. h) Service life (shall not be less than 10 years). 10 Packaging, Transportation and Storage 10.1 Packaging The packaging of the shut-off valves shall comply with the provisions of GB/T 13384.The accompanying documents and materials shall include. ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.

Similar standards: GB/T 41319   GB 27790   GB 25035   GB/T 45344   

PDF Preview: GB 44016-2024