US$90.00 · In stock · Download in 9 secondsGB 5009.128-2016: National food safety standard - Determination of cholesterol in foods
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
GB 5009.128: Historical versions
| Standard ID | USD | BUY PDF | Delivery | Standard Title (Description) | Status |
| GB 5009.128-2016 | 90 | Add to Cart | Auto, 9 seconds. | National food safety standard - Determination of cholesterol in foods | Valid |
| GB/T 5009.128-2003 | 199 | Add to Cart | 2 days | Determination of cholesterin in foods | Obsolete |
Click to Preview this PDF
Similar standards
GB 5009.128-2016: National food safety standard - Determination of cholesterol in foods
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB5009.128-2016GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA National food safety standard - Determination of cholesterol in foods Issued on. DECEMBER 23, 2016 Implemented on. JUNE 23, 2017 Issued by. National Health and Family Planning Commission of the People's Republic of China; China Food and Drug Administration.
Table of Contents
Foreword... 3 1 Scope... 4 2 Principle... 4 3 Reagents and materials... 4 4 Instruments and equipment... 5 5 Analysis steps... 5 6 Expression of analysis result... 7 7 Precision... 8 8 Other... 8 9 Principle... 8 10 Reagents and materials... 8 11 Instruments and equipment... 9 12 Analysis steps... 9 13 Expression of analysis result... 11 14 Precision... 12 15 Other... 12 16 Principle... 12 17 Reagents and materials... 12 18 Instruments and equipment... 14 19 Analysis steps... 14 20 Expression of analysis result... 15 21 Precision... 15 22 Other... 15 Annex A Cholesterol standard chromatogram... 16Foreword
This Standard replaces GB/T 5009.128-2003 Determination of cholesterol in foods, GB/T 22220-2008 Determination of cholesterol in foods - High- performance liquid chromatography and GB/T 9695.24-2008 Meat and meat products - Determination of cholesterol. Compared with GB/T 5009.128-2003, the main changes in this Standard are as follows. - modified the standard’s name to “National food safety standard - Determination of cholesterol in foods”; - added gas chromatography as method one and high-performance liquid chromatography as method two; modified colorimetric method as method three; - modified extraction solvent, the amount of ethanol and volume constant volume in pre-treatment method of gas chromatography in GB/T 9695.24- 2008. National food safety standard - Determination of cholesterol in foods1 Scope
This Standard specifies the determination methods of cholesterol in foods. This Standard applies to the determination of cholesterol in foods. Method One Gas chromatography is applicable to the determination of cholesterol in meat and meat products, eggs and egg products, milk and dairy products and other animal foods and vegetable oils and fats. Method Two High performance liquid chromatography is applicable to the determination of cholesterol in meat and meat products, eggs and egg products, milk and dairy products and other animal foods. Method Three Colorimetric method is applicable to the determination of cholesterol in meat and meat products, eggs and egg products and other animal foods. Method One -- Gas chromatography2 Principle
Saponify the sample by absolute ethanol - potassium hydroxide solution. Extract by petroleum ether and anhydrous ether mixture. Concentrate the extract to dry. After dissolving and setting volume of absolute ethanol, use gas chromatography to detect, external standard method to quantify.3 Reagents and materials
Unless otherwise indicated, the reagents used in this method are of analytical grade, water is grade one water specified in GB/T 6682. 3.1 Reagents 3.1.1 methanol (CH3OH). chromatographic pure 3.2 Regent preparation 3.2.1 60% potassium hydroxide solution. weigh 60 g of potassium hydroxide; slowly add water to dissolve and set volume to 100 mL. 3.2.2 Petroleum ether - anhydrous ether mixture (1+1, volume ratio). uniformly mix petroleum ether and anhydrous ether of equal volume. 3.3 Standard product Cholesterol standard (C27H46O, CAS number. 57-88-5). purity ≥ 99%. 3.4 Preparation of standard solution4 Instruments and equipment
4.1 Gas chromatograph. equipped with flame ionization detector (FID) 4.4 Saponification device5 Analysis steps
5.1 Sample preparation 5.1.1 Meat and meat products and other types of solid samples Take 200 g of edible part of sample to homogenize 5.1.2 Vegetable oil, dairy products and other liquid samples Take the uniform liquid sample after mixing into a sealed container to be tested. 5.2 Sample processing 5.2.1 Saponification Weigh 0.25g ~ 10g of prepared sample (nearest to 0.001 g, cholesterol content of about 0.5mg ~ 5mg) in a 250-mL round-bottomed flask. Add 30 mL of absolute ethanol, 10 mL of 60% potassium hydroxide solution. 5.2.2 Extraction Quantitatively transfer of all saponified liquid in a 250-mL separatory funnel. Use 30 mL of water to rinse the round-bottomed flask in 2~3 times. Merge the washing liquid into the separatory funnel. 5.2.3 Concentration Evaporate the extract in the flat-bottomed flask to near dryness under vacuum condition. Use absolute ethanol to dissolve and set volume to 5 mL. Determine with gas chromatograph. The pretreatment of different sample requires blank test at the same time. 5.3 Determination 5.3.1 Instrument reference conditions 5.3.2 Production of standard curve Inject the cholesterol standard series of working solution into the gas chromatograph. Under the above chromatographic conditions, measure the response value of the standard solution (peak area). Using concentration as abscissa, the peak area as ordinate, make the standard curve.6 Expression of analysis result
The content of cholesterol in the sample is calculated according to equation (1).7 Precision
The absolute difference between two independent determinations obtained under repeatability conditions shall not exceed 10% of the arithmetic mean.8 Other
When the sample volume is 0.5 g, the set volume is 5.0 mL, the detection limit shall be 0.3 mg/100g, the limit of quantification shall be 1.0 mg/100g.9 Principle
Saponify the sample by absolute ethanol - potassium hydroxide solution. Extract by petroleum ether and anhydrous ether mixture. Concentrate the extract to dry.10 Reagents and materials
Unless otherwise indicated, the reagents used in this method are of analytical grade, water is grade one water specified in GB/T 6682. 10.1 Reagents 10.2 Regent preparation 10.2.1 60% potassium hydroxide solution. weigh 60 g of potassium hydroxide; slowly add water to dissolve and set volume to 100 mL. 10.2.2 Petroleum ether - anhydrous ether mixture (1+1, volume ratio). uniformly mix petroleum ether and anhydrous ether of equal volume. 10.3 Standard product Cholesterol standard (C27H46O, CAS number. 57-88-5). purity ≥ 99%. 10.4 Preparation of standard solution11 Instruments and equipment
11.1 Homogenizer 11.2 High performance liquid chromatography. equipped with UV detector or equivalent detector ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.