HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

SN/T 2079-2008 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 2079-2008: Method for analysis of stainless and alloy steels. X-ray fluorescence spectrometry
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
SN/T 2079-2008English169 Add to Cart 3 days [Need to translate] Method for analysis of stainless and alloy steels. X-ray fluorescence spectrometry Valid SN/T 2079-2008

PDF similar to SN/T 2079-2008


Standard similar to SN/T 2079-2008

GB/T 223.89   GB/T 223.88   GB/T 3654.3   SN/T 5570   SN/T 4757   SN/T 4308   

Basic data

Standard ID SN/T 2079-2008 (SN/T2079-2008)
Description (Translated English) Method for analysis of stainless and alloy steels. X-ray fluorescence spectrometry
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard H11
Word Count Estimation 6,653
Date of Issue 2008-04-29
Date of Implementation 2008-11-01
Regulation (derived from) National-accreditation-Science [2012] 57
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the simultaneous determination of stainless steel and alloy element content in the 15 X-ray fluorescence spectroscopy methods. This standard applies to stainless steel or alloy steel Si, Mn mouth, such as the determination of 15 elements.

SN/T 2079-2008: Method for analysis of stainless and alloy steels. X-ray fluorescence spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method for analysis of stainless and alloy steels.X-ray fluorescence spectrometry Exit inspection and quarantine industry standard book People's Republic of China Stainless steel and alloy analysis X- ray fluorescence spectrometry Posted 2008-04-29 2008-11-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

Appendix A of this standard is an informative annex. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard by the People's Republic of China SZCIQ responsible for drafting. The main drafters of this standard. LI Shu-hua, Zhangqing Bo, Liu Li, Liao Wenzhong, cool white, Liu. This standard is the first release of the entry-exit inspection and quarantine industry standards. Stainless steel and alloy analysis X- ray fluorescence spectrometry Warning --- X-ray fluorescence spectrometry using a human dangerous radioactive radiation, it must be observed when using the instrument Health Instrument Safety instruction producers stated, and local regulations, and using the device must be on board before the safety training and regular safety checks.

1 Scope

This standard specifies the stainless steel and alloy steel by 15 elements in the X-ray fluorescence spectrometry method for the simultaneous determination. This standard applies to stainless steel Determination of 15 elements or alloy of Si, Mn and so on, the scope of each element in Table 1. Table 1 Scope of the elements% Element measurement range (mass fraction) Si 0.10 ~ 2.30 Mn 0.14 ~ 2.80 P 0.003 ~ 0.070 S 0.002 ~ 0.060 Cr 0.14 ~ 17.50 Ni 0.06 ~ 29.90 Cu 0.03 ~ 3.50 Mo 0.08 ~ 2.00 Element measurement range (mass fraction) V 0.05 ~ 0.65 Ti 0.01 ~ 1.10 Co 0.03 ~ 0.30 Nb 0.02 ~ 1.20 Al 0.01 ~ 1.10 W 0.08 ~ 5.40 Zr 0.01 ~ 0.35

2 Method summary

Machining the surface smooth, uniform, clean sample by the higher energy X-ray beam of radiation, X- ray fluorescence, by measuring the respective elements Characteristic lines strength analysis to determine the content of each element in the sample.

3 Reagents and materials

3.1 Detector Gas (P-10). 90% argon + 10% methane for gas-flow proportional counter. 3.2 Standard substance. Spectral stainless steel, alloy steel standard test block. Each element should be at least three reference materials, the content should be a certain room Septum, and cover the measurement range of the analyte.

4 Instrument

4.1 wavelength dispersive X- ray fluorescence spectrometer. power ≥3kW. 4.2 vacuum high frequency induction melting rapid prototyping. Temperature ≥1500 ℃. 4.3 high-purity graphite crucible. 30mL. 4.4 graphite mold. the upper end of the inner diameter of 36mm, the lower end of the inner diameter of 33mm, deep 3mm, bottom thickness (1 ~ 1.5) mm. 4.5 specimen surface processing equipment. milling machines, lathes, planers, filing and other non-polluting steel surface processing equipment. When roughing, it can also be used grinders, sand Turbines, sandpaper disc or belt grinding machines.


Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information